Quantitative analysis of contrast-enhanced ultrasonography following living donor liver transplantation: early diagnosis of middle hepatic venous occlusion

被引:1
|
作者
Im, Jiun [1 ]
Jeong, Woo Kyoung [1 ,2 ,3 ]
Lee, Min Woo [1 ,2 ,3 ]
Kim, Young Kon [2 ,3 ]
Min, Ji Hye [2 ,3 ]
Kim, Jong Man [4 ]
Choi, Gyu Seong [4 ]
Joh, Jae Won [4 ]
机构
[1] Sungkyunkwan Univ, Grad Sch, Samsung Adv Inst Hlth Sci & Technol SAIHST, Dept Med Device Management & Res, Seoul, South Korea
[2] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, 81 Irwon Ro, Seoul 06351, South Korea
[3] Sungkyunkwan Univ, Sch Med, Ctr Imaging Sci, Samsung Med Ctr, 81 Irwon Ro, Seoul 06351, South Korea
[4] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Surg, Seoul, South Korea
关键词
Liver transplantation; hepatic veins; venous thrombosis; ultrasonography; microbubbles; RIGHT LOBE GRAFT; OUTFLOW OBSTRUCTION; VASCULAR COMPLICATIONS; CONGESTION; ULTRASOUND; TRIBUTARIES; SONOGRAPHY; PERFUSION; VEINS; CT;
D O I
10.11152/mu-2906
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Aim: This study aimed to evaluate whether a quantitative contrast-enhanced ultrasonography (CEUS) study is feasible to diagnose middle hepatic venous occlusion after living donor liver transplantation (LDLT). Materials and methods: From December 2018 to July 2019, the CEUS study on the first postoperative day had been conducted in patients who underwent LDLT. 46 patients were finally included in the study. To obtain CEUS parameters from time-intensity curves (TICs) on the hepatic parenchyma, the two regions of interests (ROIs) were located in the right hepatic vein (RHV) territory and middle hepatic vein (MHV) territory of the right hepatic graft. The measured CEUS parameters were wash-in slope (WIS), peak intensity (PI), time to peak (TTP), and area under the curve (AUC). The subjects were classified into the occlusion and non-occlusion groups. In each group, the parameters measured in the RHV and MHV territories were compared with paired-sample Student's t-tests. Results: Hepatic venous occlusion was diagnosed in 25 patients (54%). The WIS, TTP, and AUC of the MHV territory (2.95 dB/sec; 22.39 sec; 204.27 dB center dot sec, respectively) were significantly different from those of the RHV territory (2.16 dB/ sec; 25.81 sec; 165.66 dB center dot sec; all p 0.05). There were no statistically significant differences in PI between the MHV and RHV territories (19.08 dB vs. 18.27 dB, respectively; p=0.259). In the non-occlusion group, there was no parameter which was significantly different between MHV and RHV territories (p 0.05). Conclusion: The parametric analysis of CEUS can help diagnose middle hepatic venous occlusion after LDLT.
引用
收藏
页码:390 / 395
页数:6
相关论文
共 50 条
  • [21] Diagnosis and differential diagnosis of liver abscesses using contrast-enhanced (SonoVue) ultrasonography
    Echeveste, T. Fontanilla
    Gonzalez, M. Mendo
    Macia, T. Canas
    Aranguena, R. Perez
    Marcos, M. J. Velasco
    Leon, C. Cortes
    RADIOLOGIA, 2009, 51 (04): : 403 - 410
  • [22] Predictive value of contrast-enhanced ultrasonography for the early diagnosis of renal dysfunction after kidney transplantation: A systematic review and meta-analysis
    Zhang, Rong
    Li, Yini
    Tang, Bin
    Luo, Zhijian
    Li, Mingxing
    JOURNAL OF CLINICAL ULTRASOUND, 2024, 52 (08) : 1056 - 1065
  • [23] Quantitative analysis of suspicious thyroid nodules by contrast-enhanced ultrasonography
    Hu, Yizhou
    Li, Ping
    Jiang, Shufei
    Li, Fenghua
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (07): : 11786 - 11793
  • [24] Contrast-Enhanced Ultrasonography with Quantitative Analysis allows Differentiation of Renal Tumor Histotypes
    Sun, Di
    Wei, Cong
    Li, Yi
    Lu, Qijie
    Zhang, Wei
    Hu, Bing
    SCIENTIFIC REPORTS, 2016, 6
  • [25] Role of contrast-enhanced ultrasound in decision support for diagnosis and treatment of hepatic artery thrombosis after liver transplantation
    Lu, Qiang
    Zhong, Xiao Fei
    Huang, Zi Xing
    Yu, Bo Yang
    Ma, Bu Yun
    Ling, Wen Wu
    Wu, Hong
    Yang, Jia Ying
    Luo, Yan
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (03) : E338 - E343
  • [26] Contrast-enhanced ultrasonography parameters in neural network diagnosis of liver tumors
    Streba, Costin Teodor
    Ionescu, Mihaela
    Gheonea, Dan Ionut
    Sandulescu, Larisa
    Ciurea, Tudorel
    Saftoiu, Adrian
    Vere, Cristin Constantin
    Rogoveanu, Ion
    WORLD JOURNAL OF GASTROENTEROLOGY, 2012, 18 (32) : 4427 - 4434
  • [27] Hepatic venous outflow reconstruction in adult right lobe living donor liver transplantation without middle hepatic vein
    Wu Hong
    Yang Jia-yin
    Yan Lu-Nan
    Li Bo
    Zeng Yong
    Wen Tian-fu
    Zhao Ji-chun
    Wang Wen-tao
    Xu Ming-qing
    Lu Qiang
    Chen Zhe-yu
    Ma Yu-kui
    Li Jin
    CHINESE MEDICAL JOURNAL, 2007, 120 (11) : 947 - 951
  • [28] Contrast-enhanced ultrasonography using Sonazoid to evaluate changes in hepatic hemodynamics in acute liver injury
    Miyazaki, Masayuki
    Kato, Masaki
    Tanaka, Masatake
    Tanaka, Kosuke
    Takao, Shinichiro
    Kohjima, Motoyuki
    Ito, Tetsuhide
    Enjoji, Munechika
    Nakamuta, Makoto
    Kotoh, Kazuhiro
    Takayanagi, Ryoichi
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2011, 26 (12) : 1749 - 1756
  • [29] Hepatic venous outflow reconstruction in adult right lobe living donor liver transplantation without middle hepatic vein
    WU Hong YANG Jia-yin YAN L-nan LI Bo ZENG Yong WEN Tian-fu ZHAO Ji-chun WANG Wen-tao XU Ming-qing LU Qiang CHEN Zhe-yu MA Yu-kui LI Jin Center of Liver Transplantation
    中华医学杂志(英文版), 2007, (11) : 947 - 951
  • [30] Impact of contrast-enhanced ultrasound in the study of hepatic artery hypoperfusion shortly after liver transplantation: contribution to the diagnosis of artery steal syndrome
    Garcia-Criado, Angeles
    Gilabert, Rosa
    Bianchi, Luis
    Vilana, Ramon
    Burrel, Marta
    Barrufet, Marta
    Oliveira, Rafael
    Carlos Garcia-Valdecasas, Juan
    Bru, Concepcion
    EUROPEAN RADIOLOGY, 2015, 25 (01) : 196 - 202