Liver Radioembolization: An Analysis of Parameters that Influence the Catheter-Based Particle-Delivery via CFD

被引:14
作者
Aramburu, Jorge [1 ]
Anton, Raul [1 ,2 ]
Rivas, Alejandro [1 ]
Ramos, Juan C. [1 ]
Sangro, Bruno [2 ,3 ,4 ]
Bilbao, Jose, I [2 ,3 ]
机构
[1] Univ Navarra, TECNUN Escuela Ingenieros, Donostia San Sebastian 20018, Spain
[2] Inst Invest Sanitaria Navarra, IdiSNA, Pamplona 31008, Spain
[3] Clin Univ Navarra, Pamplona 31008, Spain
[4] Ctr Invest Biomed Red Enfermedades Hepat & Digest, CIBEREHD, Madrid 28029, Spain
关键词
Radioembolization; hemodynamics; computational fluid-particle dynamics; liver cancer; hepatic artery; particle delivery; Y-90 GLASS MICROSPHERES; TC-99M-MACROAGGREGATED ALBUMIN SPECT; DOSIMETRIC PERSPECTIVE UNCOVERS; OUTFLOW BOUNDARY-CONDITIONS; BARE VISUAL EVALUATION; ANTIREFLUX CATHETER; PRETREATMENT DOSIMETRY; HCC RADIOEMBOLIZATION; PREDICTIVE DOSIMETRY; RESIN MICROSPHERES;
D O I
10.2174/0929867325666180622145647
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Radioembolization (RE) is a valuable treatment for liver cancer. It consists of administering radioactive microspheres by an intra-arterially placed catheter with the aim of lodging these microspheres, which are driven by the bloodstream, in the tumoral bed. Even though it is a safe treatment, some radiation-induced complications may arise. In trying to detect or solve the possible incidences that cause nontarget irradiation, simulating the particle-hemodynamics in hepatic arteries during RE by computational fluid dynamics (CFD) tools has become a valuable approach. This paper reviews the parameters that influence the outcome of RE and that have been studied via numerical simulations. In this numerical approach, the outcome of RE is regarded as successful if particles reach the artery branches that feed tumor-bearing liver segments. Up to 10 parameters have been reviewed. The variation of each parameter actually alters the hemodynamic pattern in the vicinities of the catheter tip and locally alters the incorporation of the particles into the bloodstream. Therefore, in general, the local influences of these parameters should result in global differences in terms of particle distribution in the hepatic artery branches. However, it has been observed that under some (qualitatively described) appropriate conditions where particles align with blood streamlines, the local influence resulting from a variation of a given parameter vanishes and no global differences are observed. Furthermore, the increasing number of CFD studies on RE suggests that numerical simulations have become an invaluable research tool in the study of RE.
引用
收藏
页码:1600 / 1615
页数:16
相关论文
共 62 条
[1]   Radioembolization of Liver Tumors With Yttrium-90 Microspheres [J].
Ahmadzadehfar, Hojjat ;
Biersack, Hans-Juergen ;
Ezziddin, Samer .
SEMINARS IN NUCLEAR MEDICINE, 2010, 40 (02) :105-121
[2]   Pretreatment Dosimetry in HCC Radioembolization with 90Y Glass Microspheres Cannot Be Invalidated with a Bare Visual Evaluation of 99mTc-MAA Uptake of Colorectal Metastases Treated with Resin Microspheres REPLY [J].
Amthauer, Holger ;
Ulrich, Gerhard ;
Grosser, Oliver Stephan ;
Ricke, Jens .
JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (07) :1216-1218
[3]  
Anderson John David, 1995, Computational fluid dynamics, V206
[4]  
[Anonymous], THESIS
[5]   The role of angled-tip microcatheter and microsphere injection velocity in liver radioembolization: A computational particle-hemodynamics study [J].
Aramburu, Jorge ;
Anton, Raul ;
Rivas, Alejandro ;
Carlos Ramos, Juan ;
Sangro, Bruno ;
Ignacio Bilbao, Jose .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2017, 33 (12)
[6]   Computational particle-haemodynamics analysis of liver radioembolization pretreatment as an actual treatment surrogate [J].
Aramburu, Jorge ;
Anton, Raul ;
Rivas, Alejandro ;
Carlos Ramos, Juan ;
Sangro, Bruno ;
Ignacio Bilbao, Jose .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2017, 33 (02)
[7]   Computational assessment of the effects of the catheter type on particle-hemodynamics during liver radioembolization [J].
Aramburu, Jorge ;
Anton, Raul ;
Rivas, Alejandro ;
Ramos, Juan Carlos ;
Sangro, Bruno ;
Bilbao, Jose Ignacio .
JOURNAL OF BIOMECHANICS, 2016, 49 (15) :3705-3713
[8]   Numerical investigation of liver radioembolization via computational particle-hemodynamics: The role of the microcatheter distal direction and microsphere injection point and velocity [J].
Aramburu, Jorge ;
Anton, Raid ;
Rivas, Alejandro ;
Ramos, Juan Carlos ;
Sangro, Bruno ;
Bilbao, Jose Ignacio .
JOURNAL OF BIOMECHANICS, 2016, 49 (15) :3714-3721
[9]   Liver cancer arterial perfusion modelling and CFD boundary conditions methodology: a case study of the haemodynamics of a patient-specific hepatic artery in literature-based healthy and tumour-bearing liver scenarios [J].
Aramburu, Jorge ;
Anton, Raul ;
Rivas, Alejandro ;
Carlos Ramos, Juan ;
Sangro, Bruno ;
Ignacio Bilbao, Jose .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2016, 32 (11)
[10]   Physiological outflow boundary conditions methodology for small arteries with multiple outlets: A patient-specific hepatic artery haemodynamics case study [J].
Aramburu, Jorge ;
Anton, Raul ;
Bernal, Nebai ;
Rivas, Alejandro ;
Carlos Ramos, Juan ;
Sangro, Bruno ;
Ignacio Bilbao, Jose .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2015, 229 (04) :291-306