Patient-reported outcomes for the immediate loading of mandibular overdentures supported by two implants soon after implant surgery

被引:4
作者
Komagamine, Yuriko [1 ]
Kanazawa, Manabu [1 ]
Sato, Daisuke [2 ,3 ]
Iwaki, Maiko [4 ]
Miyayasu, A. [1 ]
Minakuchi, Shunsuke [1 ]
机构
[1] Tokyo Med & Dent Univ, Grad Sch Med & Dent Sci, Gerodontol & Oral Rehabil, Tokyo, Japan
[2] Showa Univ, Sch Dent, Dept Implant Dent, Tokyo, Japan
[3] Tokyo Med & Dent Univ, Grad Sch Med & Dent Sci, Oral Implantol & Regenerat Dent Med, Tokyo, Japan
[4] Tokyo Med & Dent Univ, Univ Hosp Dent, Oral Diag & Gen Dent, Tokyo, Japan
关键词
Implant overdenture; Immediate loading; Patient reported outcome; HEALTH IMPACT PROFILE; QUALITY-OF-LIFE; COMPLETE DENTURES; VERSION; SATISFACTION; VALIDATION; RELIABILITY;
D O I
10.1016/j.jds.2021.06.021
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background/purpose: No studies have comprehensively assessed short-term pa-tient-reported outcomes after the provision of overdentures supported by two immediate im -plants. The purpose of this study was to evaluate short-term patient-reported outcomes for mandibular overdentures retained by ball attachments on two immediately loaded implants. Materials and methods: Nineteen participants with mandibular edentulism were provided with overdentures retained by ball attachments on two immediately loaded, unsplinted implants. The participants' self-assessment of their dentures and oral health-related quality of life were evaluated with the 22-item Patient's Denture Assessment (PDA), and the 19-item Japanese version of the Oral Health Impact Profile (OHIP-EDENT), respectively. Patient satisfaction was measured on a 100 mm visual analogue scale. Assessments were conducted at baseline, and at 1 and 6 months after implant surgery. Results: There were significant increases in the PDA "Lower denture" (P = 0.009) at 1 month, as well as "Function" (P = 0.002) and "Lower denture" (P = 0.009) scores at 6 months. Patient satisfaction was also significantly increased at 1 month (P = 0.007) and 6 months (P < 0.000). Significant decreases were observed in the OHIP-EDENT "Physical pain" (P = 0.046) score at 1 month, as well as the summary score (P = 0.033), "Functional limitation" (P = 0.020) and "Psychological discomfort" (P = 0.019) scores at 6 months. Conclusion: The use of two immediately loaded implants for lower mandibular complete over-dentures is associated with improvements in patient's self-assessment of dentures, satisfac-tion, and oral health-related quality of life, up to 6 months after implant surgery. (c) 2021 Association for Dental Sciences of the Republic of China. Publishing services by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons. org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:560 / 567
页数:8
相关论文
共 32 条
  • [1] Measuring patient satisfaction with mandibular prostheses
    Awad, MA
    Feine, JS
    [J]. COMMUNITY DENTISTRY AND ORAL EPIDEMIOLOGY, 1998, 26 (06) : 400 - 405
  • [2] A comparison of oral health related quality of life between complete and partial removable denture-wearing older adults in Korea
    Bae, K. H.
    Kim, C.
    Paik, D. I.
    Kim, J. B.
    [J]. JOURNAL OF ORAL REHABILITATION, 2006, 33 (05) : 317 - 322
  • [3] Validation of the Korean version of the oral health impact profile among the Korean elderly
    Bae, Kwang-Hak
    Kim, Hyun-Duck
    Jung, Se-Hwan
    Park, Deok-Young
    Kim, Jin-Bom
    Paik, Dai-Il
    Chung, Sung-Chang
    [J]. COMMUNITY DENTISTRY AND ORAL EPIDEMIOLOGY, 2007, 35 (01) : 73 - 79
  • [4] Impact of mandibular conventional denture and overdenture on quality of life and masticatory efficiency
    Cardoso, Rachel Gomes
    de Melo, Laercio Almeida
    Seabra Barbosa, Gustavo Augusto
    Calderon, Patrcia dos Santos
    Germano, Adriano Rocha
    Mestriner Junior, Wilson
    Porto Carreiro, Adriana da Fonte
    [J]. BRAZILIAN ORAL RESEARCH, 2016, 30 (01):
  • [5] Patient satisfaction and masticatory efficiency of single implant-retained mandibular overdentures using the stud and magnetic attachments
    Cheng, Tao
    Sun, Guifeng
    Huo, Jingyu
    He, Xiaoji
    Wang, Yining
    Ren, Yan-Fang
    [J]. JOURNAL OF DENTISTRY, 2012, 40 (11) : 1018 - 1023
  • [6] Clinical feasibility of mandibular implant overdenture retainers submitted to immediate load
    da Silva, Ronaldo Jose
    Mardegan Issa, Joao Paulo
    Semprini, Marisa
    Lovato da Silva, Claudia Helena
    de Vasconcelos, Paulo Batista
    Celino, Clelia Aparecida
    Siessere, Selma
    Hallak Regalo, Simone Cecilio
    [J]. GERODONTOLOGY, 2011, 28 (03) : 227 - 232
  • [7] Locators versus magnetic attachment effect on peri-implant tissue health of immediate loaded two implants retaining a mandibular overdenture: a 1-year randomised trial
    Elsyad, M. A.
    Mahanna, F. F.
    Elshahat, M. A.
    Elshoukouki, A. H.
    [J]. JOURNAL OF ORAL REHABILITATION, 2016, 43 (04) : 297 - 305
  • [8] Marginal bone resorption around immediate and delayed loaded implants supporting a locator-retained mandibular overdenture. A 1-year randomised controlled trial
    Elsyad, M. A.
    Elsaih, E. A.
    Khairallah, A. S.
    [J]. JOURNAL OF ORAL REHABILITATION, 2014, 41 (08) : 608 - 618
  • [9] Marginal bone loss adjacent to conventional and immediate loaded two implants supporting a ball-retained mandibular overdenture: a 3-year randomized clinical trial
    Elsyad, Moustafa Abdou
    Al-Mahdy, Yasmeen Fathy
    Fouad, Mohammed Mohammed
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (04) : 496 - 503
  • [10] Does immediate loading affect clinical and patient-centered outcomes of mandibular 2-unsplinted-implant overdenture? A 2-year within-case analysis
    Emami, Elham
    Cerutti-Kopplin, Daiane
    Menassa, Melanie
    Audy, Nicholas
    Kodama, Naoki
    Durand, Robert
    Rompre, Pierre
    de Grandmont, Pierre
    [J]. JOURNAL OF DENTISTRY, 2016, 50 : 30 - 36