摘要
The microscopic size and the closed characteristics of zigzag line defects at the root of friction stir welded joints frequently result in a detection inability by off-the-shelf ultrasonic weld inspection techniques. To overcome this problem, we take advantage of a non-linear ultrasonic approach by employing a slanted contact pitch-catch mode scanning using chirp-coded excitation with subsequent pulse-inversion analysis. We validated that the observed nonlinearity correlates well with the micro-crack density along the weld path. Doing so, hot spots in the pulse-inversion chirp-coded weld harmonic images can be interpreted as zones with high concentrations of micro-flaws.
引用
收藏
页数:10
相关论文
共 3 条
  • [1] Pulse-Inversion Chirp-Coded Weld Harmonic Imaging (PI-CWHI) of Friction Stir Welded Butt-Joint
    M. Tabatabaeipour
    J. Hettler
    N. T. Sewell
    J. R. Wright
    J. C. S. Wright
    S. Delrue
    K. Van Den Abeele
    Journal of Nondestructive Evaluation, 2017, 36
  • [2] Pulse Inversion Chirp Coded Tissue Harmonic Imaging (PI-CTHI) of Zebrafish Heart Using High Frame Rate Ultrasound Biomicroscopy
    Jinhyoung Park
    Ying Huang
    Ruimin Chen
    Jungwoo Lee
    Thomas M. Cummins
    Qifa Zhou
    Ching-Ling Lien
    K. K. Shung
    Annals of Biomedical Engineering, 2013, 41 : 41 - 52
  • [3] Pulse Inversion Chirp Coded Tissue Harmonic Imaging (PI-CTHI) of Zebrafish Heart Using High Frame Rate Ultrasound Biomicroscopy
    Park, Jinhyoung
    Huang, Ying
    Chen, Ruimin
    Lee, Jungwoo
    Cummins, Thomas M.
    Zhou, Qifa
    Lien, Ching-Ling
    Shung, K. K.
    ANNALS OF BIOMEDICAL ENGINEERING, 2013, 41 (01) : 41 - 52