Optimization of the readout electronics for microchannel plate delay line anodes

被引:13
|
作者
Vallerga, J [1 ]
McPhate, J [1 ]
机构
[1] Univ Calif Berkeley, Space Sci Lab, Berkeley, CA 94720 USA
关键词
microchannel plates; UV detectors; constant fraction discriminators; delay line anodes;
D O I
10.1117/12.410543
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Many current and future space missions use microchannel plate (MCP) detectors with delay line anode readouts (e.g. FUSE, GALEX and the FUV detector on the upcoming Cosmic Origins Spectrograph (COS) on the Hubble Space Telescope). Delay line anodes are used to measure the position of the centroid of the charge clouds that exit MCP detectors. This is accomplished by measuring the time difference between the arrival of the pulse at both ends of the delay line. The spatial resolution of this position determination is dependent on the accuracy of the temporal measurement. These high frequency pulses (similar to 100MHz) are usually amplified and directed to constant fraction discriminators (CFDs) whose output pulses start and stop a time to amplitude converter (TAC). This paper reviews the optimization of these circuit elements. It includes the characteristics of various delay line types (serpentine and helical) and their effect on pulse shape. The choice of amplifier filter bandpass and optimum fraction and delay for the CFDs is also presented. Examples are taken from the MCP detectors on the missions mentioned above.
引用
收藏
页码:34 / 42
页数:9
相关论文
共 50 条
  • [1] DELAY-LINE ANODES FOR MICROCHANNEL-PLATE SPECTROMETERS
    LAMPTON, M
    SIEGMUND, O
    RAFFANTI, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1987, 58 (12): : 2298 - 2305
  • [2] Low-power readout electronics for microchannel plate detectors with cross strip anodes
    Pfeifer, M.
    Barnstedt, J.
    Bauer, C.
    Diebold, S.
    Hermanutz, S.
    Kalkuhl, C.
    Kappelmann, N.
    Loechner, S.
    Schanz, T.
    Schmelling, M.
    Werner, K.
    SPACE TELESCOPES AND INSTRUMENTATION 2012: ULTRAVIOLET TO GAMMA RAY, 2012, 8443
  • [3] A Neutron Sensitive Microchannel Plate Detector with Cross Delay Line Readout
    Berry, Kevin D.
    Bilheux, Hassina Z.
    Crow, Lowell
    Diawara, Yacouba
    Feller, W. Bruce
    Iverson, Erik B.
    Martin, Adrian
    Robertson, J. Lee
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 192 - 198
  • [4] PLANAR DOUBLE DELAY-LINE READOUT TECHNIQUE FOR MICROCHANNEL PLATE DETECTORS
    LAMPTON, M
    SIEGMUND, OHW
    RAFFANTI, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (04) : 1548 - 1549
  • [5] Statistical analysis and optimization of delay line chains for pixel readout electronics
    Cantatore, E
    Campbell, M
    Chesi, E
    Corsi, F
    DeVenuto, D
    Gramegna, G
    Heijne, EHM
    Marzocca, C
    Middlekamp, P
    Scharfetter, L
    Simone, S
    Snoeys, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 395 (03): : 318 - 323
  • [6] HIGH-RESOLUTION Y-AXIS READOUT FOR DELAY-LINE MICROCHANNEL ANODES
    RAFFANTI, R
    LAMPTON, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (06): : 1506 - 1509
  • [7] DELAY-LINE READOUT OF MICROCHANNEL PLATES
    SOBOTTKA, SE
    WILLIAMS, MB
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) : 348 - 351
  • [8] FIRE - A fast image readout and electronics for microchannel plate detectors
    Lapington, JS
    Rees, K
    INSTRUMENTATION FOR UV/EUV ASTRONOMY AND SOLAR MISSIONS, 2000, 4139 : 51 - 58
  • [9] PET detector using waveshifting optical fibers and microchannel plate PMT with delay line readout
    Williams, MB
    Sealock, RM
    Majewski, S
    Weisenberger, AG
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (02) : 195 - 205
  • [10] Multiple hit readout of a microchannel plate detector with a three-layer delay-line anode
    Jagutzki, O
    Cerezo, A
    Czasch, A
    Dörner, R
    Hattass, M
    Huang, M
    Mergel, V
    Spillmann, U
    Ullmann-Pfleger, K
    Weber, T
    Schmidt-Böcking, H
    Smith, GDW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2477 - 2483