15 μm Quantum Well Infrared Photodetector for thermometric imagery in cryogenic windtunnel

被引:5
作者
Lhuillier, Emmanuel [1 ,2 ]
Ribet-Mohamed, Isabelle [1 ]
Pere-Laperne, Nicolas [1 ]
Tauvy, Michel [1 ]
Deschamps, Joel [1 ]
Nedelcu, Alexandu [3 ]
Rosencher, Emmanuel [1 ]
机构
[1] Off Natl Etud & Rech Aerosp, Ctr Palaiseau, F-91761 Palaiseau, France
[2] Univ Paris Diderot, CNRS, Lab Mat & Phenomenes Quant, UMR 7162, F-75205 Paris 13, France
[3] Alcatel Thales III V Lab, F-91761 Palaiseau, France
关键词
Infrared; Quantum well infrared photodetectors; Low flux scenario; Detector linearity; LOW-BACKGROUND APPLICATIONS; NONLINEARITY; DETECTORS; ARRAY; POWER;
D O I
10.1016/j.infrared.2010.07.010
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Quantum Well Infrared Photodetector (QWIP) usually suffer from a too moderate quantum efficiency and too large dark current which is often announced as crippling for low flux applications. Despite this reputation we demonstrate the ability of QWIP for the low infrared photon flux detection. We present the characterization of a state of the art 14.5 mu m QWIP from Alcatel-Thales III-V Lab. We developed a predictive model of the performance of an infrared instrument for a given application. The considered scene is a cryogenic wind tunnel (ETW), where a specific Si:Ga camera is currently used. Using this simulation tool we demonstrate the QWIP ability to image a low temperature scene in this scenario. QWIP detector is able to operate at 30 K with a NETD as low as 130 mK. In comparison to the current detector, the operating temperature is 20 K higher. The use of a QWIP based camera would allow a huge simplification of the optical part. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:425 / 429
页数:5
相关论文
共 16 条
[11]   Far-IR linear detector array for DARWIN [J].
Martijn, H ;
Gromov, A ;
Smuk, S ;
Malm, H ;
Asplund, C ;
Borglind, J ;
Becanovic, S ;
Alverbro, J ;
Halldin, U ;
Hirschauer, B .
INFRARED PHYSICS & TECHNOLOGY, 2005, 47 (1-2) :106-114
[12]   Low-power photocurrent nonlinearity in quantum well infrared detectors [J].
Mermelstein, C ;
Schneider, H ;
Saar, A ;
Schonbein, C ;
Walther, M ;
Bihlmann, G .
APPLIED PHYSICS LETTERS, 1997, 71 (14) :2011-2013
[13]  
NEDELCU A, 2009, INF PHYS TECHNOL, V52, P421
[14]   Third-generation infrared photodetector arrays [J].
Rogalski, A. ;
Antoszewski, J. ;
Faraone, L. .
JOURNAL OF APPLIED PHYSICS, 2009, 105 (09)
[15]   Double diffusive convection during growth of lead bromide crystals [J].
Singh, NB ;
Coriell, SR ;
Duval, WMB ;
Su, CH ;
Rajalakshmi, MEG ;
Stewart, AM .
MATERIALS RESEARCH IN LOW GRAVITY, 1997, 3123 :46-57
[16]   Characterisation of 128x192 Si:Ga focal plane array:: Study of nonuniformity, stability of its correction, and application for CRYSTAL camera [J].
Suffis, S ;
Caes, M ;
Deliot, P ;
Deschamps, J ;
Tauvy, M .
INFRARED DETECTORS AND FOCAL PLANE ARRAYS V, 1998, 3379 :235-248