Chemiluminescence flow system for the determination of sulfite

被引:17
|
作者
Qin, W
Zhang, ZJ [1 ]
Zhang, CJ
机构
[1] Shaanxi Normal Univ, Dept Chem, Xian 710062, Peoples R China
[2] Nanjing Univ, Dept Chem, Nanjing 210008, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
D O I
10.1007/s002160051023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel chemiluminescence(CL) flow system for sulfite is described based on electrostatically immobilized luminol on an anion exchange column. Sulfite is detected by the CL reaction with luminol bleeding from the column by hydrolysis. The calibration graph is linear in the range 3 x 10(-7) to 1 x 10(-5) mol/L, and the detection limit is 1 x 10(-7) mol/L. Interfering metal ions co-existing ill sample solutions could be effectively eliminated on-line by an upstream cation exchanger. A complete analysis could be performed in 1 min with a relative standard deviation of less than 5%. The system could be reused for over 50 h and has been applied successfully to the determination of sulfur dioxide in air.
引用
收藏
页码:824 / 826
页数:3
相关论文
共 50 条
  • [1] Chemiluminescence flow system for the determination of sulfite
    Wei Qin
    Z.-J. Zhang
    Cheng-Jie Zhang
    Fresenius' Journal of Analytical Chemistry, 1998, 361 : 824 - 826
  • [2] A sensitive chemiluminescence flow system for the determination of sulfite
    Huang, YM
    Zhang, C
    Zhang, XR
    Zhang, ZJ
    ANALYTICAL LETTERS, 1999, 32 (06) : 1211 - 1224
  • [3] FLOW-INJECTION CHEMILUMINESCENCE DETERMINATION OF SULFITE
    ALTAMRAH, SA
    TOWNSHEND, A
    WHEATLEY, AR
    ANALYST, 1987, 112 (06) : 883 - 886
  • [4] Flow-injection chemiluminescence determination of papaverine using cerium(IV)-sulfite system
    Zhang, S
    Zhuang, YF
    Ju, HX
    ANALYTICAL LETTERS, 2004, 37 (01) : 143 - 155
  • [5] Flow injection chemiluminescence determination of loxoprofen and naproxen with the acidic permanganate-sulfite system
    Li-Juan Wang1
    2 Institute of Analytical Sciences
    JournalofPharmaceuticalAnalysis, 2011, 1 (01) : 51 - 56
  • [6] Flow injection chemiluminescence determination of loxoprofen and naproxen with the acidic permanganate-sulfite system
    Wang, Li-Juan
    Thng, Yu-Hai
    Liu, Yang-Hao
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2011, 1 (01) : 51 - 56
  • [7] Reversed Flow Injection Chemiluminescence Determination of Pyridoxine Hydrochloride Based on the Cerium(IV)-Sodium Sulfite System
    Sun, Shuwen
    Zhou, Fulin
    Wang, Gaofeng
    Li, Yawei
    Zhou, Juxiang
    Zhang, Chenwei
    ANALYTICAL LETTERS, 2011, 44 (1-3) : 48 - 57
  • [8] Reagentless chemiluminescence flow sensor for sulfite
    Qin, W
    Zhang, ZJ
    Zhang, CJ
    ANALYTICA CHIMICA ACTA, 1998, 361 (03) : 201 - 203
  • [9] Chemiluminescence microllow injection analysis system on a chip for the determination of sulfite in food
    He, DY
    Zhang, ZJ
    Huang, Y
    ANALYTICAL LETTERS, 2005, 38 (04) : 563 - 571
  • [10] Energy Transfer Electrogenerated Chemiluminescence for the Determination of Sulfite
    Meining Zhang
    Chengxiao Zhang
    Honglan Qi
    Microchimica Acta, 2004, 144 : 155 - 160