Quality of Image of Grating Target Placed in Model of Human Eye With Corneal Aberrations as Observed Through Multifocal Intraocular Lenses

被引:25
作者
Inoue, Makoto [1 ]
Noda, Toru [2 ]
Mihashi, Toshifumi [3 ]
Ohnuma, Kazuhiko [4 ]
Bissen-Miyajima, Hiroko [5 ]
Hirakata, Akito [1 ]
机构
[1] Kyorin Univ, Kyorin Eye Ctr, Sch Med, Tokyo 1818611, Japan
[2] Natl Hosp Org, Tokyo Med Ctr, Dept Ophthalmol, Meguro Ku, Tokyo, Japan
[3] Topcon Corp, Res Inst, Opt Lab, Itabashi Ku, Osaka, Japan
[4] Chiba Univ, Fac Engn, Dept Med Syst Engn, Chiba 260, Japan
[5] Suidobashi Hosp, Dept Ophthalmol, Tokyo Dent Coll, Chiyoda Ku, Tokyo, Japan
关键词
VITREOUS SURGERY; BILATERAL IMPLANTATION; VITREORETINAL SURGERY; VISUAL FUNCTION; VISUALIZATION; OUTCOMES; ACUITY;
D O I
10.1016/j.ajo.2010.09.029
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the quality of the image of a grating target placed in a model eye viewed through multifocal intraocular lenses (IOLs). DESIGN: Laboratory investigation. METHODS: Refractive (NXG1 or PY60MV) or diffractive (ZM900 or SA60D3) multifocal IOLs were placed in a fluid-filled model eye with human corneal aberrations. A United States Air Force resolution target was placed on the posterior surface of the model eye. A flat contact lens or a wide-field contact lens was placed on the cornea. The contrasts of the gratings were evaluated under endoillumination and compared to those obtained through a monofocal IOL. RESULTS: The grating images were clear when viewed through the flat contact lens and through the central far-vision zone of the NXG1 and PY60MV, although those through the near-vision zone were blurred and doubled. The images observed through the central area of the ZM900 with flat contact lens were slightly defocused but the images in the periphery were very blurred. The contrast decreased significantly in low frequencies (P < .001). The images observed through the central diffractive zone of the SA60D3 were slightly blurred, although the images in the periphery were clearer than that of the ZM900. The images were less blurred in all of the refractive and diffractive IOLs with the wide-field contact lens. CONCLUSION: Refractive and diffractive multifocal IOLs blur the grating target but less with the wide-angle viewing system. The peripheral multifocal optical zone may be more influential on the quality of the images with contact lens system. (Am J Ophthalmol 2011;151:644-652. (C) 2011 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:644 / 652
页数:9
相关论文
共 23 条
[1]   Prospective visual evaluation of apodized diffractive intraocular lenses [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Baamonde, M. Begona ;
Mont-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (07) :1235-1243
[2]   Visual acuity comparison of 2 models of bifocal aspheric intraocular lenses [J].
Alfonso, Jose F. ;
Puchades, Cristina ;
Fernandez-Vega, Luis ;
Montes-Mico, Robert ;
Valcarcel, Beatriz ;
Ferrer-Blasco, Teresa .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (04) :672-676
[3]   Age-related changes in corneal and ocular higher-order wavefront aberrations [J].
Amano, S ;
Amano, Y ;
Yamagami, S ;
Miyai, T ;
Miyata, K ;
Samejima, T ;
Oshika, T .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 137 (06) :988-992
[4]   Autorefraction after implantation of diffractive multifocal intraocular lenses [J].
Bissen-Miyajima, Hiroko ;
Minami, Keiichiro ;
Yoshino, Mami ;
Nishimura, Mariko ;
Oki, Shinchi .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (04) :553-556
[5]   Wavefront measurements of diffractive and refractive multifocal intraocular lenses in an artificial eye [J].
Campbell, Charles E. .
JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (03) :308-311
[6]   Optics of wide-angle panoramic viewing system-assisted vitreous surgery [J].
Chalam, KV ;
Shah, VA .
SURVEY OF OPHTHALMOLOGY, 2004, 49 (04) :437-445
[7]  
Charles S, 1991, Multifocal Intraocular Lenses Slack, P209
[8]   Problems in the measurement of wavefront aberration for eyes implanted with diffractive bifocal and multifocal intralocular lenses [J].
Charman, W. Neil ;
Montes-Mico, Robert ;
Radhakrishnan, Hema .
JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (03) :280-286
[9]   One-year outcomes with new-generation multifocal intraocular lenses [J].
Cillino, Salvatore ;
Casuccio, Alessandra ;
Di Pace, Francesco ;
Morreale, Raffaella ;
Pillitteri, Francesco ;
Cillino, Giovanni ;
Lodato, Gaetano .
OPHTHALMOLOGY, 2008, 115 (09) :1508-1516
[10]   Clear lens extraction with multifocal apodized diffractive intraocular lens implantation [J].
Fernandez-Vega, Luis ;
Alfonso, Jose F. ;
Rodriguez, Pedro P. ;
Montes-Mico, Robert .
OPHTHALMOLOGY, 2007, 114 (08) :1491-1498