Comparative analysis of optimal operation strategies for district heating and cooling system based on design and actual load

被引:24
|
作者
Deng, Na [1 ]
He, Guansong [1 ]
Gao, Yuan [1 ]
Yang, Bin [2 ]
Zhao, Jun [1 ]
He, Shunming [3 ]
Tian, Xue [1 ,3 ]
机构
[1] Tianjin Univ, MOE, Sch Environm Sci & Engn, Key Lab Efficient Utilizat Low & Medium Grade Ene, Tianjin 300350, Peoples R China
[2] Umea Univ, Dept Appl Phys & Elect, SE-90187 Umea, Sweden
[3] Tianjin Ecocity Construct & Investment Co Ltd, Tianjin 300467, Peoples R China
关键词
District heating and cooling; Design load; Actual load; Optimal operation strategy; THERMAL-ENERGY STORAGE; CCHP SYSTEMS; OPTIMIZATION; DEMAND; UNCERTAINTY; TECHNOLOGY; SIMULATION; IMPACTS; COST; PUMP;
D O I
10.1016/j.apenergy.2017.07.104
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Computational load significantly influences energy and cost savings when developing an operation strategy for a district heating and cooling system. In this study, a model was identified to study the effects of the difference between design load and actual load on an optimal operation strategy. The established model is strongly dependent on the economy principle, and the proposed optimal strategy could achieve a dynamic balance between the users' load and the system energy supply. This model was validated at 30% load rate, which demonstrated an obvious cost saving of 63.6% under the actual load and 42.2% under the design load. Based on the current strategy, the optimal strategy at different load rates was analyzed with respect to two characteristics of each subsystem: energy outputs and operation costs. Furthermore, in the optimal strategy, changes in total operation costs and cost savings rates under different load rates are also discussed. The results showed that, when the load rate was changed from 30 to 75%, the savings rates based on the design load were 42.2, 17.9, 2.5, and 12.6%, and the savings rates based on the actual load were 63.6, 49.8, 34.3, and 25.7%, respectively. Based on the actual load, the energy savings advantage of the optimal operation strategy could be maximized, in particular, during the initial stage of project construction. Furthermore, the commercial software MATLAB was used for programming and calculations. The simulation results indicated that the application of the combined cooling, heating, and power system could significantly improve the cost-effectiveness.
引用
收藏
页码:577 / 588
页数:12
相关论文
共 50 条
  • [1] Optimal design and operation of district heating and cooling networks with CCHP systems in a residential complex
    Ameri, Mohammad
    Besharati, Zahed
    ENERGY AND BUILDINGS, 2016, 110 : 135 - 148
  • [2] Modelling and optimal operation of a small-scale integrated energy based district heating and cooling system
    Jing, Z. X.
    Jiang, X. S.
    Wu, Q. H.
    Tang, W. H.
    Hua, B.
    ENERGY, 2014, 73 : 399 - 415
  • [3] Multi-criteria analysis of district heating system operation strategy
    Balic, Drazen
    Maljkovic, Danica
    Loncar, Drazen
    ENERGY CONVERSION AND MANAGEMENT, 2017, 144 : 414 - 428
  • [4] Verification of energy efficiency of district heating and cooling system by simulation considering design and operation parameters
    Shimoda, Yoshlyuki
    Nagota, Tomoji
    Isayama, Naoaki
    Mizuno, Minoru
    BUILDING AND ENVIRONMENT, 2008, 43 (04) : 569 - 577
  • [5] Real operation data analysis on district heating load patterns
    Noussan, Michel
    Jarre, Matteo
    Poggio, Alberto
    ENERGY, 2017, 129 : 70 - 78
  • [6] Optimal design of a district cooling grid: structure, technology integration, and operation
    Al-Noaimi, Fadi
    Khir, Reem
    Haouari, Mohamed
    ENGINEERING OPTIMIZATION, 2019, 51 (01) : 160 - 183
  • [7] Optimization and Analysis of Operation Strategies for Combined Cooling, Heating and Power System
    Li, Zhengyi
    Huo, Zhaoyi
    Yin, Hongchao
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [8] Multi-objective optimal operation and energy coupling analysis of combined cooling and heating system
    Wei, Dajun
    Chen, Alian
    Sun, Bo
    Zhang, Chenghui
    ENERGY, 2016, 98 : 296 - 307
  • [9] Diameter optimization of district heating and cooling piping network based on hourly load
    Zeng, Jing
    Han, Jie
    Zhang, Guoqiang
    APPLIED THERMAL ENGINEERING, 2016, 107 : 750 - 757
  • [10] Comparative thermodynamic performance analysis of a cascade system for cooling and heating applications
    Yilmaz, Fatih
    Selbas, Resat
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2019, 16 (09) : 674 - 686