Atrial Fibrillation Classification with Smart Wearables Using Short-Term Heart Rate Variability and Deep Convolutional Neural Networks

被引:28
作者
Ramesh, Jayroop [1 ]
Solatidehkordi, Zahra [1 ]
Aburukba, Raafat [1 ]
Sagahyroon, Assim [1 ]
机构
[1] Amer Univ Sharjah, Dept Comp Sci & Engn, POB 26666, Sharjah, U Arab Emirates
关键词
biomedical informatics; cardiovascular disease; deep learning; ECG; heart rate variability; machine learning; PPG; smartphones; smart wearables; PHOTOPLETHYSMOGRAPHY; SIGNALS; IMPACT;
D O I
10.3390/s21217233
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Atrial fibrillation (AF) is a type of cardiac arrhythmia affecting millions of people every year. This disease increases the likelihood of strokes, heart failure, and even death. While dedicated medical-grade electrocardiogram (ECG) devices can enable gold-standard analysis, these devices are expensive and require clinical settings. Recent advances in the capabilities of general-purpose smartphones and wearable technology equipped with photoplethysmography (PPG) sensors increase diagnostic accessibility for most populations. This work aims to develop a single model that can generalize AF classification across the modalities of ECG and PPG with a unified knowledge representation. This is enabled by approximating the transformation of signals obtained from low-cost wearable PPG sensors in terms of Pulse Rate Variability (PRV) to temporal Heart Rate Variability (HRV) features extracted from medical-grade ECG. This paper proposes a one-dimensional deep convolutional neural network that uses HRV-derived features for classifying 30-s heart rhythms as normal sinus rhythm or atrial fibrillation from both ECG and PPG-based sensors. The model is trained with three MIT-BIH ECG databases and is assessed on a dataset of unseen PPG signals acquired from wrist-worn wearable devices through transfer learning. The model achieved the aggregate binary classification performance measures of accuracy: 95.50%, sensitivity: 94.50%, and specificity: 96.00% across a five-fold cross-validation strategy on the ECG datasets. It also achieved 95.10% accuracy, 94.60% sensitivity, 95.20% specificity on an unseen PPG dataset. The results show considerable promise towards seamless adaptation of gold-standard ECG trained models for non-ambulatory AF detection with consumer wearable devices through HRV-based knowledge transfer.
引用
收藏
页数:24
相关论文
共 78 条
  • [1] Abadi M, 2016, ACM SIGPLAN NOTICES, V51, P1, DOI [10.1145/2951913.2976746, 10.1145/3022670.2976746]
  • [2] A deep convolutional neural network model to classify heartbeats
    Acharya, U. Rajendra
    Oh, Shu Lih
    Hagiwara, Yuki
    Tan, Jen Hong
    Adam, Muhammad
    Gertych, Arkadiusz
    Tan, Ru San
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2017, 89 : 389 - 396
  • [3] Aliamiri Alireza, 2018, 2018 IEEE EMBS International Conference on Biomedical & Health Informatics (BHI), P442, DOI 10.1109/BHI.2018.8333463
  • [4] Photoplethysmography
    Alian, Aymen A.
    Shelley, Kirk H.
    [J]. BEST PRACTICE & RESEARCH-CLINICAL ANAESTHESIOLOGY, 2014, 28 (04) : 395 - 406
  • [5] American Association of Medical Instrumentation, 2013, EC572012 ANSIAAMI
  • [6] [Anonymous], 2016, NEUROKIT PYTHON TOOL
  • [7] [Anonymous], 2017, IMOTIONS 0321
  • [8] [Anonymous], 2018, P 11 INT JOINT C BIO
  • [9] [Anonymous], CARDIOVASC DIS
  • [10] [Anonymous], 2019, ARXIV180308375V2 CSN