The axial compressive behavior of stone-lightweight aggregate concrete-filled steel tubular stub columns

被引:19
作者
Zhang, Xianggang [1 ,2 ]
Zhang, Songpeng [2 ]
Fan, Yuhui [2 ]
Ding, Yahong [2 ]
Wang, Xingguo [2 ]
Meng, Ercong [3 ]
机构
[1] Wuchang Univ Technol, Sch Intelligent Construct, Wuhan 430223, Peoples R China
[2] Henan Polytech Univ, Sch Civil Engn, Jiaozuo 454003, Henan, Peoples R China
[3] Southwest Univ, CET Coll Engn & Technol, Chongqing 400715, Peoples R China
基金
中国国家自然科学基金;
关键词
Stone-lightweight aggregate concrete-filled; steel tubular; Energy dissipation; Stiffness; Finite element; The whole process analysis; Grey correlation analysis; STRESS-STRAIN MODEL; TUBE COLUMNS; DUNE SAND; CAPACITY; STRENGTH; CEMENT;
D O I
10.1016/j.conbuildmat.2021.123815
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To study the axial compressive mechanical properties of stone-lightweight aggregate concrete-filled steel tubular (SLACFST) stub columns, five circular stone-lightweight aggregate concrete-filled steel tubular (CSLACFST) and square stone-lightweight aggregate concrete-filled steel tubular (S-SLACFST) stub columns were made by taking the volume replacement ratio of natural gravel aggregate and ceramsite in lightweight aggregate concrete as a variation parameter. After observing their mechanical process and failure modes, the axial load-displacement curves of the specimens were obtained. The influence of gravel replacement ratio on the energy dissipation and stiffness of the specimens was analyzed, and a simplified model for predicting their stiffness degradation was proposed. The plastic damage model was then used to verify those specimens with a finite element, and this model was subsequently adopted in the whole process analysis of these specimens and in finding out the loading relationship between the steel tube and core stone-lightweight aggregate concrete (SLAC). The effects of varying parameters on the compressive behavior of the specimens were investigated, and the extent to which these varying parameters are related to the ultimate bearing capacity of SLACFST was assessed via a grey correlation analysis. Results show that the rigidity of the calculated load-displacement curves in the elastic and elastic-plastic stages is greater than that of the test curves, but the ultimate bearing capacity and peak displacements agree with the test values within an acceptable error. Moreover, the simulated failure modes of the control specimens are the same as the test failure modes. Before reaching the ultimate bearing capacity, the core SLAC made a significant contribution to the bearing capacity of the specimen due to the constraint of steel tube. The negligible influence of gravel replacement ratio on the ultimate bearing capacity of SLACFST specimen. In addition, the nature gravel can inhibit the floating of LAC to a certain extent, so as to achieve the purpose of using SLAC to make SLACFST, reducing the self-weight of the structure while having higher bearing capacity. (c) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:19
相关论文
共 39 条
[1]   Finite element study to address the axial capacity of the circular concrete-filled steel tubular stub columns [J].
Al-Ani, Yahia Raad .
THIN-WALLED STRUCTURES, 2018, 126 :2-15
[2]   Behavior of Reinforced Lightweight Aggregate Concrete-filled Circular Steel Tube Columns Under Axial Loading [J].
Al-Eliwi, Baraa J. M. ;
Ekmekyapar, Talha ;
Al-Samaraie, Mohanad I. A. ;
Dogru, M. Hanifi .
STRUCTURES, 2018, 16 :101-111
[3]   Structural behavior of concrete-filled steel tube short columns stiffened by external and internal continuous spirals [J].
Alrebeh, Salih K. ;
Ekmekyapar, Talha .
STRUCTURES, 2019, 22 :98-108
[4]  
[Anonymous], 2018, Code for Design of Concrete Structures
[5]   Ultimate moment capacity of foamed and lightweight aggregate concrete-filled steel tubes [J].
Assi, IM ;
Qudeimat, EM ;
Hunaiti, YM .
STEEL AND COMPOSITE STRUCTURES, 2003, 3 (03) :199-212
[6]   An analytical model for stress-strain behavior of confined concrete [J].
Binici, B .
ENGINEERING STRUCTURES, 2005, 27 (07) :1040-1051
[7]   Experimental and numerical investigation of concrete-filled hot-finished and cold-formed steel elliptical tubular stub columns [J].
Cai, Yancheng ;
Quach, Wai-Meng ;
Young, Ben .
THIN-WALLED STRUCTURES, 2019, 145
[8]   Axial capacity of rectangular concrete-filled steel tube columns - DOE approach [J].
Chitawadagi, Manojkumar V. ;
Narasimhan, Mattur C. ;
Kulkarni, S. M. .
CONSTRUCTION AND BUILDING MATERIALS, 2010, 24 (04) :585-595
[9]   Numerical and Experimental Investigations of Different Cross-Sectional Configuration of Plain Concrete and CFST Short Columns Under Axial Compression [J].
Dey, Palash ;
Gupta, R. K. ;
Laskar, A. I. .
INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2019, 17 (10A) :1585-1601
[10]   INTERFACE BOND BEHAVIOUR BETWEEN CIRCULAR STEEL TUBE AND LIGHTWEIGHT AGGREGATE CONCRETE [J].
Fu, Z. Q. ;
Ge, H. B. ;
Ji, B. H. ;
Chen, J. J. .
ADVANCED STEEL CONSTRUCTION, 2018, 14 (03) :424-437