Composite cure and shrinkage associated with high intensity curing light

被引:0
作者
Yap, AUJ
Wong, NY
Siow, KS
机构
[1] Natl Univ Singapore, Fac Dent, Dept Restorat Dent, Singapore, Singapore
[2] Natl Univ Singapore, Fac Dent, Dept Chem, Singapore, Singapore
[3] Natl Univ Singapore, Fac Sci, Dept Chem, Singapore, Singapore
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study investigated the effectiveness of cure and post-gel shrinkage of three visible light-cured composite resins (In Ten-S [IT], Ivoclar Vivadent; Z100 [ZO], 3M-ESPE; Tetric Ceram [TC], Ivoclar Vivadent) when polymerized with a very high intensity (1296 +/- 2 mW/cm(2)) halogen light (Astralis 10, Ivoclar Vivadent) for 10 seconds. Irradiation with a conventional (494 3 mW/cm(2)) halogen light (Spectrum, Dentsply) for 40 seconds was used for comparison. The effectiveness of cure was assessed by computing the hardness gradient between the top and bottom surfaces of 2-mm composite specimens after curing. A strain-monitoring device was used to measure the linear polymerization shrinkage associated with the various composites and curing lights. A sample size of five was used for both experiments. Data was analyzed using ANOVA/Scheffe's post-hoc and Independent Samples t-tests at significance level 0.05. Results showed that the effect of the curing method on the effectiveness of cure and shrinkage was material-dependent. Polymerization of IT and TC with Spectrum for 40 seconds resulted in significantly more effective cure than polymerization with Astralis for 10 seconds. Polymerization of ZO with Spectrum for 40 seconds resulted in significantly more shrinkage than polymerization with Astralis for 10 seconds. In view of the substantial time saving, using high intensity lights may be a viable method to polymerize composites.
引用
收藏
页码:357 / 364
页数:8
相关论文
共 38 条
  • [1] COMPOSITE RESTORATIVE RESINS - COMPOSITION VERSUS WALL-TO-WALL POLYMERIZATION CONTRACTION
    ASMUSSEN, E
    [J]. ACTA ODONTOLOGICA SCANDINAVICA, 1975, 33 (06) : 337 - 344
  • [2] ASMUSSEN E, 1982, SCANDINAVIAN J DENT, V90, P90
  • [3] UPDATE ON DENTAL COMPOSITE RESTORATIONS
    BAYNE, SC
    HEYMANN, HO
    SWIFT, EJ
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1994, 125 (06) : 687 - 701
  • [4] Bertolotti R L, 1991, Pract Periodontics Aesthet Dent, V3, P53
  • [5] Burgess J O, 1999, Pract Periodontics Aesthet Dent, V11, P125
  • [6] CORRELATION OF CYTOTOXICITY, FILLER LOADING AND CURING TIME OF DENTAL COMPOSITES
    CAUGHMAN, WF
    CAUGHMAN, GB
    SHIFLETT, RA
    RUEGGEBERG, F
    SCHUSTER, GS
    [J]. BIOMATERIALS, 1991, 12 (08) : 737 - 740
  • [7] Christensen R P, 1999, Compend Contin Educ Dent Suppl, pS42
  • [8] RELAXATION OF POLYMERIZATION CONTRACTION STRESSES BY FLOW IN DENTAL COMPOSITES
    DAVIDSON, CL
    DEGEE, AJ
    [J]. JOURNAL OF DENTAL RESEARCH, 1984, 63 (02) : 146 - 148
  • [9] Polymerization shrinkage and polymerization shrinkage stress in polymer-based restoratives
    Davidson, CL
    Feilzer, AJ
    [J]. JOURNAL OF DENTISTRY, 1997, 25 (06) : 435 - 440
  • [10] DENEHY GE, 1993, QUINTESSENCE INT, V24, P517