Thermodynamic Performance Evaluation of a Solar Parabolic Dish Assisted Multigeneration System

被引:16
作者
Abid, Muhammad [1 ]
Khan, Muhammad Sajid [2 ]
Ratlamwala, Tahir Abdul Hussain [3 ]
机构
[1] Cyprus Int Univ, Dept Energy Syst Engn, Fac Engn, North Cyprus Via Mersin 10, TR-10000 Nicosia, Turkey
[2] MUST, Dept Mech Engn, Mirpur 10250, Ajk, Pakistan
[3] Natl Univ Sci & Technol, Dept Mech Engn, Islamabad 24090, Pakistan
来源
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME | 2019年 / 141卷 / 06期
关键词
absorption system; parabolic dish system; COP; exergy; combined cycle; THERMAL POWER-PLANT; LITHIUM BROMIDE; EXERGY ANALYSIS; 2ND LAW; REFRIGERATION; ENERGY; WATER; SIMULATION; COLLECTOR; DESIGN;
D O I
10.1115/1.4044022
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The concentration ratio of the parabolic dish solar collector (PDSC) is considered to be one of the highest among the concentrated solar power technologies (CSPs); therefore, such system is capable of generating more heat rate. The present paper focuses on the integration of the PDSC with the combined cycle (gas cycle as the toping cycle and steam cycle as the bottoming cycle) along with the utilization of waste heat from the power cycle to drive the single effect lithium bromide/water absorption cycle. Molten salt is used as a heat transfer fluid in the solar collector. The engineering equation solver (EES) is employed for the mathematical modeling and simulation of the solar integrated system. The various operating parameters (beam radiation, inlet and ambient temperatures of heat transfer fluid, mass flow rate of heat transfer fluid, evaporator temperature, and generator temperature) are varied to analyze their influence on the performance parameters (power output, overall energetic and exergetic efficiencies, outlet temperature of the receiver, and as coefficient of performance (COP) and exergy efficiencies) of the integrated system. The results show that the overall energy and exergy efficiencies are observed to be 39.9% and 42.95% at ambient temperature of 27 degrees C and solar irradiance of 1000 W/m(2). The outlet temperature of the receiver is noticed to decrease from 1008 K to 528 K for an increase in the mass flow rate from 0.01 to 0.05 kg/s. The efficiency rate of the power plant is 38%, whereas COP of single effect absorption system is 0.84, and it will decrease from 0.87 to 0.79. However, the evaporator load is decreased to approximately 9.7% by increasing the generator temperature from 47 degrees C to 107 degrees C.
引用
收藏
页数:10
相关论文
共 39 条
[1]   Performance assessment of parabolic dish and parabolic trough solar thermal power plant using nanofluids and molten salts [J].
Abid, M. ;
Ratlamwala, T. A. H. ;
Atikol, U. .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2016, 40 (04) :550-563
[2]   Solar assisted multi-generation system using nanofluids: A comparative analysis [J].
Abid, Muhammad ;
Ratlamwala, Tahir A. H. ;
Atikol, Ugur .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2017, 42 (33) :21429-21442
[3]   Energy, exergy, economic and environmental (4E) analyses of a conceptual solar aided coal fired 500 MWe thermal power plant with thermal energy storage option [J].
Adibhatla, Sairam ;
Kaushik, S. C. .
SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2017, 21 :89-99
[4]   Evaluation of the energy efficiency of combined cycle gas turbine. Case study of Tashkent thermal power plant, Uzbekistan [J].
Aminov, Zarif ;
Nakagoshi, Nobukazu ;
Xuan, Tran Dang ;
Higashi, Osamu ;
Alikulov, Khusniddin .
APPLIED THERMAL ENGINEERING, 2016, 103 :501-509
[5]  
[Anonymous], 2012, REN POW GEN COSTS 20
[6]  
APHORNRATANA S, 1995, INT J REFRIG, V18, P244
[7]  
ATAER OE, 1991, INT J REFRIG, V14, P86
[8]   Innovation in concentrated solar power [J].
Barlev, David ;
Vidu, Ruxandra ;
Stroeve, Pieter .
SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2011, 95 (10) :2703-2725
[9]   Design, simulation and optimization of a compound parabolic collector [J].
Bellos, E. ;
Korres, D. ;
Tzivanidis, C. ;
Antonopoulos, K. A. .
SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2016, 16 :53-63
[10]  
Bellos J., 2014, RENEW ENERG, V94, P213