Comprehensive Comparison of Virtual Monoenergetic and Linearly Blended Reconstruction Techniques in Third-Generation Dual-Source Dual-Energy Computed Tomography Angiography of the Thorax and Abdomen

被引:123
作者
Albrecht, Moritz H. [1 ]
Trommer, Jesko [1 ]
Wichmann, Julian L. [1 ]
Scholtz, Jan-Erik [1 ]
Martin, Simon S. [1 ]
Lehnert, Thomas [1 ]
Vogl, Thomas J. [1 ]
Bodelle, Boris [1 ]
机构
[1] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Frankfurt, Germany
关键词
dual-energy computed tomography; virtual monoenergetic imaging; computed tomography angiography; image contrast and quality; contrast-enhanced computed tomography; CT PULMONARY ANGIOGRAPHY; REDUCED IODINE LOAD; PROSPECTIVE RANDOMIZED-TRIAL; KILOELECTRON-VOLT-SETTINGS; AORTIC-ANEURYSM REPAIR; TO-NOISE RATIO; IMAGE-QUALITY; CONTRAST ENHANCEMENT; CORONARY-ANGIOGRAPHY; NECK-CANCER;
D O I
10.1097/RLI.0000000000000272
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The aim of this study was to perform an objective and subjective image analysis of traditional and advanced noise-optimized virtual monoenergetic imaging (VMI) algorithms and standard linearly blended images in third-generation dual-source dual-energy computed tomography angiography (DE-CTA) of the thorax and abdomen. Materials and Methods: Thoracoabdominal DE-CTA examinations of 55 patients (36 male; mean age, 64.2 +/- 12.7 years) were included in this retrospective institutional review board-approved study. Dual-energy computed tomography angiography data were reconstructed using standard linearly blended M_0.6 (merging 60% low kiloelectron volt [90 kV] with 40% high kiloelectron volt [150 kV] spectrum), traditional (VMI), and advanced VMI (VMI+) algorithms. Monoenergetic series were calculated ranging from 40 to 120 keV with 10 keV increments. Attenuation and standard deviation of 8 arteries and various anatomical landmarks of the thorax and abdomen were measured to calculate contrast-to-noise ratio values. Two radiologists subjectively assessed image quality, contrast conditions, noise, and visualization of small arterial branches using 5-point Likert scales. Results: Vascular attenuation of VMI and VMI+ series showed a gradual increase from high to low kiloelectron volt levels without significant differences between both algorithms (P < 0.894). VMI+ 40-keV series showed the highest contrast-to-noise ratio for both thoracic and abdominal DE-CTA (P < 0.001), albeit revealing higher noise than M_0.6 images (objectively and subjectively, P < 0.001) and were rated best for visualization of small arterial branches in the subjective analysis (P < 0.109). Substantially increased noise was found for VMI 40 and 50 keV series compared with all other reconstructions (objectively and subjectively, P < 0.001). VMI+ images at 100 keV+ were rated best regarding image noise (P < 0.843), whereas VMI+ reconstructions at 70 keV were found to have superior subjective image quality (P < 0.031) compared with other series except for 60 and 80 keV VMI+ series (P < 0.587). Contrast conditions at 50 keV VMI+ were rated superior compared with 60 to 100 keV VMI and VMI+ reconstructions (P < 0.012). Conclusions: General image quality of DE-CTA examinations can be substantially improved using the VMI+ algorithm with observer preference of 70 keV, while 40 to 50 keV series provide superior contrast and improved visualization of small arterial branches compared with traditional VMI and standard linearly blended series.
引用
收藏
页码:582 / 590
页数:9
相关论文
共 37 条
  • [1] Albrecht M. H., 2015, EUR RADIOL
  • [2] Assessment of an Advanced Monoenergetic Reconstruction Technique in Dual-Energy Computed Tomography of Head and Neck Cancer
    Albrecht, Moritz H.
    Scholtz, Jan-Erik
    Kraft, Johannes
    Bauer, Ralf W.
    Kaup, Moritz
    Dewes, Patricia
    Bucher, Andreas M.
    Burck, Iris
    Wagenblast, Jens
    Lehnert, Thomas
    Kerl, J. Matthias
    Vogl, Thomas J.
    Wichmann, Julian L.
    [J]. EUROPEAN RADIOLOGY, 2015, 25 (08) : 2493 - 2501
  • [3] Value of monoenergetic low-kV dual energy CT datasets for improved image quality of CT pulmonary angiography
    Apfaltrer, Paul
    Sudarski, Sonja
    Schneider, David
    Nance, John W., Jr.
    Haubenreisser, Holger
    Fink, Christian
    Schoenberg, Stefan O.
    Henzler, Thomas
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (02) : 322 - 328
  • [4] Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation
    Bamberg, Fabian
    Dierks, Alexander
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Becker, Christoph R.
    Johnson, Thorsten R. C.
    [J]. EUROPEAN RADIOLOGY, 2011, 21 (07) : 1424 - 1429
  • [5] Evaluation of different keV-settings in dual-energy CT angiography of the aorta using advanced image-based virtual monoenergetic imaging
    Beeres, Martin
    Trommer, Jesko
    Frellesen, Claudia
    Nour-Eldin, Nour-Eldin A.
    Scholtz, Jan E.
    Herrmann, Eva
    Vogl, Thomas J.
    Wichmann, Julian L.
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 (01) : 137 - 144
  • [6] Image Fusion in Dual Energy Computed Tomography Effect on Contrast Enhancement, Signal-to-Noise Ratio and Image Quality in Computed Tomography Angiography
    Behrendt, Florian F.
    Schmidt, Bernhard
    Plumhans, Cedric
    Keil, Sebastian
    Woodruff, Seth G.
    Ackermann, Diana
    Muehlenbruch, Georg
    Flohr, Thomas
    Guenther, Rolf W.
    Mahnken, Andreas H.
    [J]. INVESTIGATIVE RADIOLOGY, 2009, 44 (01) : 1 - 6
  • [7] Noise-optimized virtual monoenergetic images and iodine maps for the detection of venous thrombosis in second-generation dual-energy CT (DECT): an ex vivo phantom study
    Bongers, Malte N.
    Schabel, Christoph
    Krauss, Bernhard
    Tsiflikas, Ilias
    Ketelsen, Dominik
    Mangold, Stefanie
    Claussen, Claus D.
    Nikolaou, Konstantin
    Thomas, Christoph
    [J]. EUROPEAN RADIOLOGY, 2015, 25 (06) : 1655 - 1664
  • [8] Monochromatic image reconstruction by dual energy imaging allows half iodine load computed tomography coronary angiography
    Carrascosa, Patricia
    Leipsic, Jonathon A.
    Capunay, Carlos
    Deviggiano, Alejandro
    Vallejos, Javier
    Goldsmit, Alejandro
    Rodriguez-Granillo, Gaston A.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (10) : 1915 - 1920
  • [9] Substantial iodine volume load reduction in CT angiography with dual-energy imaging: insights from a pilot randomized study
    Carrascosa, Patricia
    Capunay, Carlos
    Rodriguez-Granillo, Gaston A.
    Deviggiano, Alejandro
    Vallejos, Javier
    Leipsic, Jonathon A.
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (08) : 1613 - 1620
  • [10] A COEFFICIENT OF AGREEMENT FOR NOMINAL SCALES
    COHEN, J
    [J]. EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1960, 20 (01) : 37 - 46