Comparative Study of Tritium Analysis Method with High-Volume Counting Vial

被引:1
|
作者
Yoon, Yoon Yeol [1 ,2 ]
Kim, Yongcheol [1 ]
机构
[1] Korea Inst Geosci & Mineral Resources, Geol Environm Div, Daejeon, South Korea
[2] Korea Inst Geosci & Mineral Resources, Div Geol Environm, 124 Gwahak Ro, Daejeon 34132, South Korea
来源
关键词
LSC-LB7; High Volume Vial; Tritium; UNDERGROUND WATERS;
D O I
10.14407/jrpr.2020.45.3.142
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Background: Tritium (3H) analysis in groundwater was difficult because of its low activity. Therefore, the electrolytic enrichment method was used. To improve the detection limit and for performing simple analysis, a high-volume counting vial with the available liquid scintillation counter (LSC) was investigated. Further, it was compared with a conventional 20-mL counting vial.Materials and Methods: The LSC with the electrolytic enrichment method was used 3H analy-sis in groundwater. A high-volume 145-mL counting vial was compared with a conventional 20-mL counting vial to determine the counting characteristics of different LSCs.Results and Discussion: When a Quantulus LSC was used, the counting window between channels 35 and 250 was used. The background count was approximately 1.86 cpm, and the counting efficiency increased from 8% to 40% depending on the mixing ratio of the volume of sample and cocktail solution. For LSC-LB7, the optimum counting window was between 1 and 4.9 keV, which was selected by the factory (Hitachi Aloka Medical Ltd., Japan) by considering quenching using a standard external gamma source. The background count of LSC-LB7 was ap-proximately 3.60 +/- 0.29 cpm when the 145-mL vial was used and 2.22 +/- 0.17 cpm when the 20-mL vial was used. The minimum detectable activity (MDA) of the 20-mL vial was greater for LSC-LB7 than for Quantulus. The MDA with the 145-mL vial was improved to 0.3 Bq/L when compared with the value of 1.6 Bq/L for the 20-mL vial.Conclusion: The counting efficiency when using the 145-mL vial was 27%, whereas it was 18% when using the 20-mL vial. This difference can be attributed to the vial volume. The figure of merit (FOM) of the 145-mL vial was four times greater than that of the 20-mL vial because the volume of the former vial is approximately seven times greater than that of the latter. Further, the MDA for 3H decreased from 1.6 to 0.3 Bq/L. The counting efficiency and FOM of LSC-LB7 was slightly less than those of Quantulus when the 20-mL vial was used. The background counting rate of the Quantulus was lower than that of the LSC-LB7.
引用
收藏
页码:142 / 146
页数:5
相关论文
共 50 条
  • [31] A high-volume sampling method for total coliform and E. coli
    Hargy, Thomas M.
    Rosen, Jeffrey
    LeChevallier, Mark
    Friedman, Melinda
    Clancy, Jennifer L.
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2010, 102 (03): : 79 - +
  • [32] High-volume, high-accuracy, SGML document capture: A case study
    RichterWills, S
    SGML EUROPE '96, 1996, : 115 - 122
  • [33] Robotic and laparoscopic liver resection—comparative experiences at a high-volume German academic center
    E. Lorenz
    J. Arend
    M. Franz
    M. Rahimli
    A. Perrakis
    V. Negrini
    A. A. Gumbs
    R. S. Croner
    Langenbeck's Archives of Surgery, 2021, 406 : 753 - 761
  • [34] Cost Analysis of Pancreaticoduodenectomy at a High-Volume Robotic Hepatopancreaticobiliary Surgery Program
    Beauchamp, R. Daniel
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2021, 232 (04) : 491 - 492
  • [35] Analysis of the Weekend Effect at a High-Volume Center for the Treatment of Intracranial Aneurysms
    Koester, Stefan W.
    Catapano, Joshua S.
    Rumalla, Kavelin
    Srinivasan, Visish M.
    Rhodenhiser, Emmajane G.
    Hartke, Joelle N.
    Benner, Dimitri
    Winkler, Ethan A.
    Cole, Tyler S.
    Baranoski, Jacob F.
    Jadhav, Ashutosh P.
    Ducruet, Andrew F.
    Albuquerque, Felipe C.
    Lawton, Michael T.
    WORLD NEUROSURGERY, 2023, 169 : E83 - E88
  • [36] An analysis of 37 patients with uterine leiomyosarcoma at a high-volume cancer center
    Solmaz, Ulas
    Dereli, Levent
    Demirtas, Gulsah Selvi
    Ekin, Atalay
    Mat, Emre
    Gezer, Cenk
    Hasdemir, Pinar Solmaz
    Sayhan, Sevil
    Sanci, Muzaffer
    Askar, Niyazi
    TURKISH JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2015, 12 (03) : 158 - 163
  • [37] The Impact of Obesity on Total Hip Arthroplasty Outcomes When Performed by High-Volume Surgeons - A Propensity Matched Analysis From a High-Volume Urban Center
    Ashkenazi, Itay
    Thomas, Jeremiah
    Lawrence, Kyle W.
    Meftah, Morteza
    Rozell, Joshua C.
    Schwarzkopf, Ran
    JOURNAL OF ARTHROPLASTY, 2024, 39 (06): : 1412 - 1418
  • [38] Problem-adaptable document analysis and understanding for high-volume applications
    Bertin Klein
    Andreas R. Dengel
    Document Analysis and Recognition, 2003, 6 (3): : 167 - 180
  • [39] Comparative Analysis of Therapeutic Strategies in Post-Cardiotomy Cardiogenic Shock: Insight into a High-Volume Cardiac Surgery Center
    Baldan, B. Ufuk
    Hegeman, Romy R. M. J. J.
    Bos, Nelleke M. J. P.
    Smeenk, Hans G.
    Klautz, Robert J. M.
    Klein, Patrick
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (07)
  • [40] Voltage regulator module noise analysis for high-volume server applications
    Matoglu, E
    Pham, N
    Selli, G
    Lai, M
    Connor, S
    Drewniak, JL
    Archambeault, B
    Wang, D
    Kuhn, D
    Hashemi, R
    de Araujo, DN
    Cases, M
    Wilkie, P
    Herrman, P
    Patel, P
    Electrical Performance of Electronic Packaging, 2004, : 267 - 270