Comparative Study of Tritium Analysis Method with High-Volume Counting Vial

被引:1
|
作者
Yoon, Yoon Yeol [1 ,2 ]
Kim, Yongcheol [1 ]
机构
[1] Korea Inst Geosci & Mineral Resources, Geol Environm Div, Daejeon, South Korea
[2] Korea Inst Geosci & Mineral Resources, Div Geol Environm, 124 Gwahak Ro, Daejeon 34132, South Korea
来源
关键词
LSC-LB7; High Volume Vial; Tritium; UNDERGROUND WATERS;
D O I
10.14407/jrpr.2020.45.3.142
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Background: Tritium (3H) analysis in groundwater was difficult because of its low activity. Therefore, the electrolytic enrichment method was used. To improve the detection limit and for performing simple analysis, a high-volume counting vial with the available liquid scintillation counter (LSC) was investigated. Further, it was compared with a conventional 20-mL counting vial.Materials and Methods: The LSC with the electrolytic enrichment method was used 3H analy-sis in groundwater. A high-volume 145-mL counting vial was compared with a conventional 20-mL counting vial to determine the counting characteristics of different LSCs.Results and Discussion: When a Quantulus LSC was used, the counting window between channels 35 and 250 was used. The background count was approximately 1.86 cpm, and the counting efficiency increased from 8% to 40% depending on the mixing ratio of the volume of sample and cocktail solution. For LSC-LB7, the optimum counting window was between 1 and 4.9 keV, which was selected by the factory (Hitachi Aloka Medical Ltd., Japan) by considering quenching using a standard external gamma source. The background count of LSC-LB7 was ap-proximately 3.60 +/- 0.29 cpm when the 145-mL vial was used and 2.22 +/- 0.17 cpm when the 20-mL vial was used. The minimum detectable activity (MDA) of the 20-mL vial was greater for LSC-LB7 than for Quantulus. The MDA with the 145-mL vial was improved to 0.3 Bq/L when compared with the value of 1.6 Bq/L for the 20-mL vial.Conclusion: The counting efficiency when using the 145-mL vial was 27%, whereas it was 18% when using the 20-mL vial. This difference can be attributed to the vial volume. The figure of merit (FOM) of the 145-mL vial was four times greater than that of the 20-mL vial because the volume of the former vial is approximately seven times greater than that of the latter. Further, the MDA for 3H decreased from 1.6 to 0.3 Bq/L. The counting efficiency and FOM of LSC-LB7 was slightly less than those of Quantulus when the 20-mL vial was used. The background counting rate of the Quantulus was lower than that of the LSC-LB7.
引用
收藏
页码:142 / 146
页数:5
相关论文
共 50 条
  • [1] A comparative study of self-consolidating concretes incorporating high-volume natural pozzolan or high-volume fly ash
    Monteiro, Paulo J.M. (monteiro@ce.berkeley.edu), 1600, Elsevier Ltd (67):
  • [2] A comparative study of self-consolidating concretes incorporating high-volume natural pozzolan or high-volume fly ash
    Celik, Kemal
    Meral, Cagla
    Mancio, Mauricio
    Mehta, P. Kumar
    Monteiro, Paulo J. M.
    CONSTRUCTION AND BUILDING MATERIALS, 2014, 67 : 14 - 19
  • [3] A comparative study of self-consolidating concretes incorporating high-volume natural pozzolan or high-volume fly ash
    Celik, Kemal
    Meral, Cagla
    Mancio, Mauricio
    Mehta, P. Kumar
    Monteiro, Paulo J.M.
    Construction and Building Materials, 2014, 67 (PART A) : 14 - 19
  • [4] Robotic versus laparoscopic adrenalectomy: a comparative study in a high-volume center
    Karen Pineda-Solís
    Heriberto Medina-Franco
    Martin J. Heslin
    Surgical Endoscopy, 2013, 27 : 599 - 602
  • [5] Robotic versus laparoscopic adrenalectomy: a comparative study in a high-volume center
    Pineda-Solis, Karen
    Medina-Franco, Heriberto
    Heslin, Martin J.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2013, 27 (02): : 599 - 602
  • [7] Analytical study of high-volume crystallization equations
    Moshinskii, AI
    RUSSIAN JOURNAL OF APPLIED CHEMISTRY, 1995, 68 (06) : 858 - 863
  • [8] ZERO AIR - SELECTION OF A HIGH-VOLUME PREPARATION METHOD
    BARSOCCHI, AT
    KNOBEL, R
    AMERICAN LABORATORY, 1980, 12 (02) : 81 - &
  • [9] Comparative Utilization of Reverse and Anatomic Total Shoulder Arthroplasty: A Comprehensive Analysis of a High-volume Center
    Chalmers, Peter N.
    Salazar, Dane H.
    Romeo, Anthony A.
    Keener, Jay D.
    Yamaguchi, Ken
    Chamberlain, Aaron M.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2018, 26 (24) : E504 - E510
  • [10] Comparative study of the outcome between alcohol and gallstone pancreatitis in a high-volume tertiary care center
    Samanta, Jayanta
    Dhaka, Narendra
    Gupta, Pankaj
    Singh, Anupam K.
    Yadav, Thakur D.
    Gupta, Vikas
    Sinha, Saroj K.
    Kochhar, Rakesh
    JGH OPEN, 2019, 3 (04): : 338 - 343