The Use of Piezoceramics As Electrical Energy Harvesters Within Instrumented Knee Implant During Walking

被引:46
作者
Almouahed, Shaban [1 ,2 ]
Gouriou, Manuel [1 ,2 ]
Hamitouche, Chafiaa [1 ,2 ]
Stindel, Eric [2 ,3 ]
Roux, Christian [1 ,2 ]
机构
[1] TELECOM Bretagne, Inst TELECOM, Dept Image & Informat Proc, F-29238 Brest, France
[2] French Natl Inst Hlth & Med Res, Lab Med Informat Proc, F-29609 Brest, France
[3] Univ Western Brittany, F-29200 Brest, France
关键词
Piezoelectric energy harvesters; postoperative instability; self-powered sensors; total knee replacement; POWER GENERATION;
D O I
10.1109/TMECH.2011.2159512
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The goal of our paper is to quantify the electrical energy that can be harvested within a new generation of instrumented knee implant during normal walking. This generation of knee implant is proposed to assess the in vivo anteroposterior and mediolateral distributions of tibiofemoral force on the tibial baseplate without the need to be powered from an external source of energy. The proposed self-powered diagnostic knee implant can provide the clinicians with useful information on the sagittal and coronal instabilities of the prosthetic knee throughout its lifespan. Four piezoelectric elements were embedded within the anteromedial, posteromedial, anterolateral, and posterolateral compartments of the tibial baseplate. These elements can simultaneously be used to sense the force distribution and generate the electric power needed to supply the acquisition, processing, and transmission system located in the stem of the implant. In order to study the power generation issue, OrCAD/PSpice and MATLAB/Simulink models of the piezoelectric element have been developed to quantify the electrical energy harvested under operating conditions close to those encountered in vivo during normal walking. Furthermore, an experimental prototype of the self-powered diagnostic knee implant has been designed, developed, and tested in our laboratory (LaTIM, INSERM U650, Brest, France) in order to validate the modeling results.
引用
收藏
页码:799 / 807
页数:9
相关论文
共 22 条
[1]  
Almouahed S., 2008, P 3 INT C INF COMM T, P1
[2]   Design and Evaluation of Instrumented Smart Knee Implant [J].
Almouahed, Shaban ;
Gouriou, Manuel ;
Hamitouche, Chafiaa ;
Stindel, Eric ;
Roux, Christian .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (04) :971-982
[3]  
[Anonymous], 2002, 142431 ISO
[4]  
[Anonymous], 2004, 142433 ISO
[5]  
Cady W.G., 1946, PIEZOELECTRICITY INT
[6]   Towards a piezoelectric vibration-powered microgenerator [J].
Glynne-Jones, P ;
Beeby, SP ;
White, NM .
IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 2001, 148 (02) :68-72
[7]  
HVID I, 1988, CLIN ORTHOP RELAT R, P210
[8]   A Self-Powered Telemetry System to Estimate the Postoperative Instability of a Knee Implant [J].
Lahuec, Cyril ;
Almouahed, Shaban ;
Arzel, Matthieu ;
Gupta, Deepak ;
Hamitouche, Chafiaa ;
Jezequel, Michel ;
Stindel, Eric ;
Roux, Christian .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (03) :822-825
[9]   Biomedical applications of batteries [J].
Latham, R ;
Linford, R ;
Schlindwein, W .
SOLID STATE IONICS, 2004, 172 (1-4) :7-11
[10]  
Mallela Venkateswara Sarma, 2004, Indian Pacing Electrophysiol J, V4, P201