Comparing monolithic and microparticular capillary columns for the separation and analysis of peptide mixtures by liquid chromatography-mass spectrometry

被引:38
作者
Toll, H
Wintringer, R
Schweiger-Hufnagel, U
Huber, CG
机构
[1] Univ Saarland, Dept Chem Instrumental Anal & Bioanal, D-66041 Saarbrucken, Germany
[2] Bruker Daltonik, Bremen, Germany
关键词
capillary liquid chromatography; ESI-MS; HPLC; peptide; proteomic;
D O I
10.1002/jssc.200500155
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A mixture of ten proteins was trypsinized and injected onto poly-(styrene-divinylbenzene) monolithic columns (60 x 0.20 or 0.10 mm ID) and a column packed with C18 silica particles (75 x 0.075 mm ID), respectively. The columns were eluted at 200-2000 nL/min with gradients of ACN in 0.050% TFA. Eluting peptides were detected by ESI-MS/MS and subsequently identified by database searching. The 100 mu m ID monolithic column showed the highest cumulative Mowse scores based on the highest ion scores for the peptides and the largest number of identified peptides. It is shown that the number of identified peptides strongly depends on the dynamic range within the peptide mixture. In consequence, all proteins were identified in a mixture of relatively balanced analyte amounts (12.5-80 fmol) whereas only peptides for six out of ten proteins were found in a sample of high-dynamic range (0.65-270 fmol). The 100 mu m monolithic column showed the highest reproducibility for peptide identifications in three consecutive runs. Depending on sample amount, 57-72% of the identified peptides were detectable in each of the three runs of triplicate analyses. The results demonstrate the high suitability of 100 mu m monolithic columns for high-resolution peptide separations in proteomic research.
引用
收藏
页码:1666 / 1674
页数:9
相关论文
共 35 条
[1]   FLOW-THROUGH PARTICLES FOR THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF BIOMOLECULES - PERFUSION CHROMATOGRAPHY [J].
AFEYAN, NB ;
GORDON, NF ;
MAZSAROFF, I ;
VARADY, L ;
FULTON, SP ;
YANG, YB ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY, 1990, 519 (01) :1-29
[2]   Deactivation of frits for use in capillary high-performance liquid chromatography and capillary electrochromatography with characterization by imaging with laser-induced fluorescence [J].
Behnke, B ;
Johansson, J ;
Zhang, SG ;
Bayer, E ;
Nilsson, S .
JOURNAL OF CHROMATOGRAPHY A, 1998, 818 (02) :257-259
[3]   Applications of silica-based monolithic HPLC columns [J].
Cabrera, K .
JOURNAL OF SEPARATION SCIENCE, 2004, 27 (10-11) :843-852
[4]   Comparison of the efficiency of microparticulate and monolithic capillary columns [J].
Eeltink, S ;
Decrop, WMC ;
Rozing, GP ;
Schoenmakers, PJ ;
Kok, WT .
JOURNAL OF SEPARATION SCIENCE, 2004, 27 (17-18) :1431-1440
[5]   AN APPROACH TO CORRELATE TANDEM MASS-SPECTRAL DATA OF PEPTIDES WITH AMINO-ACID-SEQUENCES IN A PROTEIN DATABASE [J].
ENG, JK ;
MCCORMACK, AL ;
YATES, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (11) :976-989
[6]   Capillary columns with in situ formed porous monolithic packing for micro high-performance liquid chromatography and capillary electrochromatography [J].
Gusev, I ;
Huang, X ;
Horváth, C .
JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (01) :273-290
[7]   A computational study of the porosity effects in silica monolithic columns [J].
Gzil, P ;
Vervoort, N ;
Baron, GV ;
Desmet, G .
JOURNAL OF SEPARATION SCIENCE, 2004, 27 (10-11) :887-896
[8]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON CONTINUOUS POLYMER BEDS [J].
HJERTEN, S ;
LIAO, JL ;
ZHANG, R .
JOURNAL OF CHROMATOGRAPHY, 1989, 473 (01) :273-275
[9]   Monolithic silica columns for high-efficiency separations by high-performance liquid chromatography [J].
Ishizuka, N ;
Kobayashi, H ;
Minakuchi, H ;
Nakanishi, K ;
Hirao, K ;
Hosoya, K ;
Ikegami, T ;
Tanaka, N .
JOURNAL OF CHROMATOGRAPHY A, 2002, 960 (1-2) :85-96
[10]   Low-attomole electrospray ionization MS and MS/MS analysis of protein tryptic digests using 20-μm-i.d. polystyrene-divinylbenzene monolithic capillary columns [J].
Ivanov, AR ;
Zang, L ;
Karger, BL .
ANALYTICAL CHEMISTRY, 2003, 75 (20) :5306-5316