Design strategies of viscous dampers for seismic protection of building structures: A review

被引:259
作者
De Domenico, D. [1 ]
Ricciardi, G. [1 ]
Takewaki, I. [2 ]
机构
[1] Univ Messina, Dept Engn, I-98166 Messina, Italy
[2] Kyoto Univ, Dept Architecture & Architectural Engn, Nishikyo Ku, Kyoto 6158540, Japan
关键词
Fluid viscous dampers; Optimal damper design; Energy dissipation devices; Earthquake protection; Stochastic earthquake excitation; Numerical optimization; MOMENT-RESISTING FRAMES; BASE-ISOLATED BUILDINGS; SHEAR-TYPE STRUCTURES; ENERGY-DISSIPATION; OPTIMAL PLACEMENT; VISCOELASTIC DAMPERS; OPTIMUM DESIGN; VIBRATION CONTROL; 5-STEP PROCEDURE; GENERAL CONCEPTS;
D O I
10.1016/j.soildyn.2018.12.024
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Fluid viscous dampers (FVDs) are well-established supplemental energy dissipation devices that have been widely used for earthquake protection of structures. Optimal design, placement and sizing of FVDs have been extensively investigated in the last four decades. In this review paper, an overview of the most popular methodologies from the abundant literature in the field is presented. Key aspects and main characteristics of the different strategies to identify the optimal damping coefficients and the optimal placement of FVDs are scrutinized in a comparative manner. The optimal design problem is often solved through a numerical approach to a constrained optimization problem, by minimizing some performance criteria that are representative measures of the system response. With reference to two simple benchmark six-story shear-type structures subject to both a stochastic earthquake excitation and 44 natural ground motions extracted from the FEMA P695 record set, comparison of the seismic performance is carried out considering FVDs designed according to different methods - an overall number of 138 different design scenarios are incorporated in this comparative study. These methods are based either on a desired (target) damping ratio constraint or on a fixed total cost, here roughly related to the sum of the damping coefficients of the added FVDs. Some energy-based perspectives are also given in this review paper in order to interpret the seismic performance in terms of the amount of energy dissipated by the FVDs, out of the total input energy from the earthquake excitation.
引用
收藏
页码:144 / 165
页数:22
相关论文
共 192 条
[81]   Advanced scalar intensity measures for collapse capacity prediction of steel moment resisting frames with fluid viscous dampers [J].
Jamshidiha, H. R. ;
Yakhchalian, M. ;
Mohebi, B. .
SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2018, 109 :102-118
[82]   An optimization study for viscous dampers between adjacent buildings [J].
Kandemir-Mazanoglu, Elif Cagda ;
Mazanoglu, Kemal .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2017, 89 :88-96
[83]   Assessment of capacity design of columns in steel moment resisting frames with viscous dampers [J].
Karavasilis, Theodore L. .
SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2016, 88 :215-222
[84]   Automatic generation of smart earthquake-resistant building system: Hybrid system of base-isolation and building-connection [J].
Kasagi, M. ;
Fujita, K. ;
Tsuji, M. ;
Takewaki, I .
HELIYON, 2016, 2 (02)
[85]   Energy-based seismic design of structures with buckling-restrained braces [J].
Kim, J ;
Choi, H ;
Chung, L .
STEEL AND COMPOSITE STRUCTURES, 2004, 4 (06) :437-452
[86]   RESPONSE SPECTRUM METHOD FOR MULTISUPPORT SEISMIC EXCITATIONS [J].
KIUREGHIAN, AD ;
NEUENHOFER, A .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1992, 21 (08) :713-740
[87]   Building earthquake resilience in sustainable cities in terms of input energy [J].
Kojima, K. ;
Fujita, K. ;
Takewaki, I. .
SUSTAINABLE CITIES AND SOCIETY, 2014, 12 :46-62
[88]   A two-step direct method for estimating the seismic response of nonlinear structures equipped with nonlinear viscous dampers [J].
Landi, Luca ;
Fabbri, Omar ;
Diotallevi, Pier Paolo .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2014, 43 (11) :1641-1659
[89]   Output frequency response function based design of additional nonlinear viscous dampers for vibration control of multi-degree-of-freedom systems [J].
Lang, Z. Q. ;
Guo, P. F. ;
Takewaki, I. .
JOURNAL OF SOUND AND VIBRATION, 2013, 332 (19) :4461-4481
[90]   Noniterative optimization procedure for seismic weakening and damping of inelastic structures [J].
Lavan, O. ;
Cimellaro, G. P. ;
Reinhom, A. M. .
JOURNAL OF STRUCTURAL ENGINEERING, 2008, 134 (10) :1638-1648