Inverted Internal Limiting Membrane Flap Technique versus Internal Limiting Membrane Peeling for Large Macular Holes: A Meta-Analysis of Randomized Controlled Trials

被引:13
作者
Yu, Ji-Guo [1 ]
Wang, Jing [1 ]
Xiang, Yi [1 ]
机构
[1] Huazhong Univ Sci & Technol, Cent Hosp Wuhan, Dept Ophthalmol, Tongji Med Coll, Wuhan, Peoples R China
关键词
Inverted internal limiting membrane flap technique; Internal limiting membrane peeling; Large macular hole; Meta-analysis; SURGERY; OUTCOMES; EFFICACY; CLOSURE;
D O I
10.1159/000515283
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Vitrectomy with internal limiting membrane (ILM) peeling is an effective surgical procedure for the treatment of macular holes (MHs). However, there is a possibility of poor postoperative anatomical closure with conventional ILM peeling for MHs larger than 400 mu m. Therefore, a novel inverted ILM flap technique was developed for such cases. Objectives: This meta-analysis study was performed to evaluate and compare the anatomical and visual outcomes of the inverted ILM flap technique and ILM peeling in large MHs. Methods: The Cochrane Library, PubMed, and Embase databases were searched to identify randomized controlled trials (RCTs). The trial eligibility and risk of bias were assessed according to Cochrane review methods. The primary outcome measures included MH closure rate and postoperative visual acuity (VA). Subgroup analysis of postoperative VA based on follow-up time was also conducted. Pooled odds ratios (ORs), weighted mean difference (WMD), and 95% confidence intervals (CIs) were calculated. Statistical analysis was performed using RevMan 5.3 software. Results: Five RCTs with a total of 155 eyes in the inverted ILM flap group and 161 eyes in the ILM peeling group were included in this meta-analysis. Statistical meta-analysis revealed that the overall MH closure rate in the inverted ILM flap group was significantly higher than that in the ILM peeling group (OR = 3.10; 95% CI: 1.25-7.66; p = 0.01). The postoperative VA was significantly better in the inverted ILM flap group than the ILM peeling group (WMD = -0.14; 95% CI: -0.21 to -0.07; p = 0.0002). The subgroup meta-analysis indicated that the postoperative VA was significantly better in the inverted ILM flap group than the ILM peeling group (WMD = -0.17; 95% CI: -0.26 to -0.08; p = 0.0004) at the 3-month follow-up. However, no significant difference was observed between the 2 groups at the 6-month follow-up (WMD = -0.09; 95% CI: -0.20 to 0.02; p = 0.10). Conclusions: Vitrectomy with the inverted ILM flap technique showed a higher anatomical closure rate as well as visual gain - although only in the short term as no difference in visual recovery was found at the 6-month follow-up - than did ILM peeling in large MHs. The inverted ILM flap technique should be considered as a preferred and routine procedure for the treatment of patients with MHs larger than 400 mu m. (C) 2021 The Author(s). Published by S. Karger AG, Basel
引用
收藏
页码:713 / 722
页数:10
相关论文
共 50 条
[41]   Vitrectomy with internal limiting membrane peeling versus its flap insertion for macular hole in high myopia: a Meta-analysis [J].
Wu, Ya-Jun ;
Rao, Jie ;
Wu, Kang-Rui ;
Wu, Na ;
Cheng, Yi ;
Xu, Xiao-Xuan ;
Yan, Li ;
Shao, Yi ;
Tian, Yu ;
Wu, Xiao-Rong .
INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (01) :141-148
[42]   Comparative study of inverted internal limiting membrane (ILM) flap and ILM peeling technique in large macular holes: a randomized-control trial [J].
Naresh Babu Kannan ;
Piyush Kohli ;
Haemoglobin Parida ;
O. O. Adenuga ;
Kim Ramasamy .
BMC Ophthalmology, 18
[43]   Inverted ILM flap technique versus conventional ILM peeling for idiopathic large macular holes: A meta-analysis of randomized controlled trials [J].
Chen, Guohai ;
Tzekov, Radouil ;
Jiang, Fangzheng ;
Mao, Sihong ;
Tong, Yuhua ;
Li, Wensheng .
PLOS ONE, 2020, 15 (07)
[44]   Inverted internal limiting membrane flap technique for very large macular hole [J].
Mitali Khodani ;
Pooja Bansal ;
Raja Narayanan ;
Jay Chhablani .
International Journal of Ophthalmology, 2016, (08) :1230-1232
[45]   Surgical outcomes of inverted internal limiting membrane flap technique for large macular hole [J].
Mahalingam, Prabhushanker ;
Sambhav, Kumar .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2013, 61 (10) :601-U110
[46]   Internal Limiting Membrane Flap Technique for Macular Holes: Is it Ready for Prime Time? [J].
Koo, Eubee B. ;
Smiddy, William E. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2018, 38 (05) :865-869
[47]   Pars plana vitrectomy with internal limiting membrane flap versus pars plana vitrectomy with conventional internal limiting membrane peeling for large macular hole [J].
Ghoraba, Hashem ;
Rittiphairoj, Thanitsara ;
Akhavanrezayat, Amir ;
Karaca, Irmak ;
Matsumiya, Wataru ;
Pham, Brandon ;
Mishra, Kapil ;
Yasar, Cigdem ;
Mobasserian, Azadeh ;
Abdelkarem, Amira Ahmed ;
Nguyen, Quan Dong .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2023, (08)
[48]   Comparative analysis of large macular hole surgery using an internal limiting membrane insertion versus inverted flap technique [J].
Park, Jong Ho ;
Lee, Seung Min ;
Park, Sung Who ;
Lee, Ji Eun ;
Byon, Ik Soo .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2019, 103 (02) :245-250
[49]   Inverted internal limiting membrane flap technique in the surgical treatment of macular holes: 8-year experience [J].
Silva, Nisa ;
Ferreira, Natalia ;
Pessoa, Bernardete ;
Correia, Nuno ;
Beirao, Joao Melo ;
Meireles, Angelina .
INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (02) :499-507
[50]   Modified inverted internal limiting membrane flap technique for macular hole closure [J].
Kakehi, Sayaka ;
Mizuguchi, Tadashi ;
Tanikawa, Atsuhiro ;
Horiguchi, Masayuki .
JAPANESE JOURNAL OF OPHTHALMOLOGY, 2022, 66 (06) :543-548