Continuous noninvasive hemoglobin monitoring: ready for prime time?

被引:8
作者
Suehiro, Koichi [1 ]
Joosten, Alexandre [1 ]
Alexander, Brenton [1 ]
Cannesson, Maxime [1 ]
机构
[1] Univ Calif Irvine, Dept Anesthesiol & Perioperat Care, Orange, CA 92868 USA
关键词
accuracy; bleeding; hemoglobin; noninvasive; transfusion; PULSE CO-OXIMETRY; ACCURACY; TRANSFUSION; COOXIMETER; PRECISION; HEMOCUE; RISK; CELL;
D O I
10.1097/MCC.0000000000000197
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose of review Determination of hemoglobin (Hb) concentration is essential for the detection of anemia and hemorrhage and is widely used to evaluate a patient for a possible blood transfusion. Although commonly accepted as intrinsic to the process, traditional laboratory measurements of Hb are invasive, intermittent, and time-consuming. Noninvasive Hb (NIHb)-monitoring devices have recently become available and promise the potential for detecting sudden changes in a patient's Hb level. In addition to reduced delays in clinical intervention, these devices also allow for a reduction in patient discomfort, infection risk, required personnel, and long-term costs. Unfortunately, it has been shown that many clinical factors can influence their accuracy. Recent findings Many studies have been published on the accuracy and precision of NIHb-monitoring devices in various clinical settings. A recent meta-analysis has shown a small mean difference but wide limits of agreement between NIHb and laboratory measurements, indicating that caution should be used by physicians when making clinical decisions based on this device. Summary NIHb measurements may currently be considered to be a supplemental tool for monitoring trends in Hb concentration, but are not currently developed enough to replace an invasive approach. Moreover, further studies are still required before implementing NIHb in the clinical decision-making process. Specifically, no studies have demonstrated that this technology improves clinical outcomes or patient safety.
引用
收藏
页码:265 / 270
页数:6
相关论文
共 50 条
[41]   Feasibility and accuracy of noninvasive continuous hemoglobin monitoring using transesophageal photoplethysmography in porcine model [J].
Ling Peng ;
Long Zhao ;
Xue Zhang ;
Yi Zhang ;
Meng Ding ;
Zhibin Lin ;
Hao Jiang ;
Yuchen Huang ;
Bo Gao ;
Wei Wei .
BMC Anesthesiology, 24
[42]   CT Colonography: Ready for Prime Time? [J].
Cash, Brooks D. .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2010, 105 (10) :2128-2132
[43]   Vital exhaustion: ready for prime time? [J].
Luepker, Russell V. ;
Schulz, S. Charles .
EUROPEAN HEART JOURNAL, 2015, 36 (22) :1361-1363
[44]   Gamma Prime Fibrinogen and Childhood Obesity: Ready for Prime Time? [J].
Tarango, Cristina ;
Ware, Russell E. .
JOURNAL OF PEDIATRICS, 2013, 163 (02) :315-316
[45]   Evaluation of noninvasive hemoglobin monitoring in children with congenital heart diseases [J].
Kamel, Mohamed Maher ;
Hasanin, Ahmed ;
Nawar, Beshoy ;
Mostafa, Maha ;
Jacob, Victor F. ;
Elhadi, Hany ;
Alsadek, Wafaa ;
Elmetwally, Sarah A. .
PEDIATRIC ANESTHESIA, 2020, 30 (05) :571-576
[46]   TRENDING, ACCURACY AND PRECISION OF NONINVASIVE HEMOGLOBIN MONITORING DURING HEMODILUTION [J].
Marques, N. R. ;
Kramer, G. ;
Salter, M. ;
Voigt, R. B. ;
Kinsky, M. .
ANESTHESIA AND ANALGESIA, 2013, 116 :311-312
[47]   Comparison of the gold standard of hemoglobin measurement with the clinical standard (BGA) and noninvasive hemoglobin measurement (SpHb) in small children: a prospective diagnostic observational study [J].
Wittenmeier, Eva ;
Bellosevich, Sophia ;
Mauff, Susanne ;
Schmidtmann, Irene ;
Eli, Michael ;
Pestel, Gunther ;
Noppens, Ruediger R. .
PEDIATRIC ANESTHESIA, 2015, 25 (10) :1046-1053
[48]   Precision of noninvasive hemoglobin-level measurement by pulse co-oximetry in patients admitted to intensive care units for severe gastrointestinal bleeds [J].
Coquin, Julien ;
Dewitte, Antoine ;
Le Manach, Yannick ;
Caujolle, Marie ;
Joannes-Boyau, Olivier ;
Fleureau, Catherine ;
Janvier, Gerard ;
Ouattara, Alexandre .
CRITICAL CARE MEDICINE, 2012, 40 (09) :2576-2582
[49]   The Comparison of Hemoglobin Values Measured by Blood and Continuous Non-Invasive Monitoring (SpHb) in Newborn Infants [J].
Kazanasmaz, Halil ;
Demir, Mahmut .
JOURNAL OF TROPICAL PEDIATRICS, 2021, 67 (03)
[50]   The relative trending accuracy of noninvasive continuous hemoglobin monitoring during hemodialysis in critically ill patients [J].
Hiroshi Yamada ;
Minako Saeki ;
Junko Ito ;
Kazuhiro Kawada ;
Aya Higurashi ;
Hiromi Funakoshi ;
Kohji Takeda .
Journal of Clinical Monitoring and Computing, 2015, 29 :107-112