Continuous noninvasive hemoglobin monitoring: ready for prime time?

被引:8
作者
Suehiro, Koichi [1 ]
Joosten, Alexandre [1 ]
Alexander, Brenton [1 ]
Cannesson, Maxime [1 ]
机构
[1] Univ Calif Irvine, Dept Anesthesiol & Perioperat Care, Orange, CA 92868 USA
关键词
accuracy; bleeding; hemoglobin; noninvasive; transfusion; PULSE CO-OXIMETRY; ACCURACY; TRANSFUSION; COOXIMETER; PRECISION; HEMOCUE; RISK; CELL;
D O I
10.1097/MCC.0000000000000197
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose of review Determination of hemoglobin (Hb) concentration is essential for the detection of anemia and hemorrhage and is widely used to evaluate a patient for a possible blood transfusion. Although commonly accepted as intrinsic to the process, traditional laboratory measurements of Hb are invasive, intermittent, and time-consuming. Noninvasive Hb (NIHb)-monitoring devices have recently become available and promise the potential for detecting sudden changes in a patient's Hb level. In addition to reduced delays in clinical intervention, these devices also allow for a reduction in patient discomfort, infection risk, required personnel, and long-term costs. Unfortunately, it has been shown that many clinical factors can influence their accuracy. Recent findings Many studies have been published on the accuracy and precision of NIHb-monitoring devices in various clinical settings. A recent meta-analysis has shown a small mean difference but wide limits of agreement between NIHb and laboratory measurements, indicating that caution should be used by physicians when making clinical decisions based on this device. Summary NIHb measurements may currently be considered to be a supplemental tool for monitoring trends in Hb concentration, but are not currently developed enough to replace an invasive approach. Moreover, further studies are still required before implementing NIHb in the clinical decision-making process. Specifically, no studies have demonstrated that this technology improves clinical outcomes or patient safety.
引用
收藏
页码:265 / 270
页数:6
相关论文
共 50 条
[31]   Novel noninvasive point-of-care device for real time hemoglobin monitoring [J].
Timm, Ulrich ;
Gewiss, Helge ;
Kraitl, Jens ;
Stuepmann, Kirstin ;
Hinz, Michael ;
Koball, Sebastian ;
Ewald, Hartmut .
OPTICAL DIAGNOSTICS AND SENSING XIV: TOWARD POINT-OF-CARE DIAGNOSTICS, 2014, 8951
[32]   A noninvasive hemoglobin monitor in the pediatric intensive care unit [J].
Phillips, Michael R. ;
Khoury, Amal L. ;
Bortsov, Andrey V. ;
Marzinsky, Amy ;
Short, Kathy A. ;
Cairns, Bruce A. ;
Charles, Anthony G. ;
Joyner, Benny L., Jr. ;
McLean, Sean E. .
JOURNAL OF SURGICAL RESEARCH, 2015, 195 (01) :257-262
[33]   Development and Validation of a Photoplethysmography System for Noninvasive Monitoring of Hemoglobin Concentration [J].
Liu, Hongyun ;
Peng, Fulai ;
Hu, Minlu ;
Shi, Jinlong ;
Wang, Guojing ;
Ai, Haiming ;
Wang, Weidong .
JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING, 2020, 2020
[34]   Rapid diagnosis of invasive candidiasis: ready for prime-time? [J].
Clancy, Cornelius J. ;
Minh-Hong Nguyen .
CURRENT OPINION IN INFECTIOUS DISEASES, 2019, 32 (06) :546-552
[35]   Performance Evaluation of a Noninvasive Hemoglobin Monitoring Device [J].
Gayat, Etienne ;
Bodin, Antoine ;
Sportiello, Caroline ;
Boisson, Mireille ;
Dreyfus, Jean-Francois ;
Mathieu, Emmanuel ;
Fischler, Marc .
ANNALS OF EMERGENCY MEDICINE, 2011, 57 (04) :330-333
[36]   Continuous hemoglobin and plethysmography variability index monitoring can modify blood transfusion practice and is associated with lower mortality [J].
Cros, Jerome ;
Dalmay, Francois ;
Yonnet, Sandra ;
Charpentier, Matthieu ;
Tran-Van-Ho, Jessica ;
Renaudeau, Francois ;
Drouet, Anais ;
Guilbaut, Pierre ;
Marin, Benoit ;
Nathan, Nathalie .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2020, 34 (04) :683-691
[37]   A Comparison of Lidocaine and Bupivacaine Digital Nerve Blocks on Noninvasive Continuous Hemoglobin Monitoring in a Randomized Trial in Volunteers [J].
Miller, Ronald D. ;
Ward, Theresa A. ;
McCulloch, Charles E. ;
Cohen, Neal H. .
ANESTHESIA AND ANALGESIA, 2014, 118 (04) :766-771
[38]   Impact of Increased End-Tidal Carbon Dioxide on Continuous Noninvasive Hemoglobin Monitoring during Laparoscopic Gastrectomy: A Randomized Controlled Study [J].
Kim, Ha-Yeon ;
Choi, Jong-Bum ;
Han, Sang-Uk ;
Lee, Hye-Sun ;
Lee, Kyuhyeok ;
Kim, Ji-Eun .
JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (02)
[39]   Evaluation of noninvasive hemoglobin measurements in trauma patients [J].
Moore, Laura J. ;
Wade, Charles E. ;
Vincent, Laura ;
Podbielski, Jeanette ;
Camp, Elizabeth ;
del Junco, Deborah ;
Radhakrishnan, Hari ;
McCarthy, James ;
Gill, Brijesh ;
Holcomb, John B. .
AMERICAN JOURNAL OF SURGERY, 2013, 206 (06) :1041-1047
[40]   Continuous noninvasive hemoglobin monitoring estimates timing for detecting anemia better than clinicians: a randomized controlled trial [J].
Bo Tang ;
Xuerong Yu ;
Li Xu ;
Afang Zhu ;
Yuelun Zhang ;
Yuguang Huang .
BMC Anesthesiology, 19