Design criteria of a control strategy for hybrid power filters based on current and voltage detection

被引:2
|
作者
Litran, Salvador P. [1 ]
Salmeron, Patricio [1 ]
机构
[1] Univ Huelva, Dept Elect Engn, Huelva, Spain
关键词
active filters; harmonic; hybrid power filters; power factor; power quality; HARMONIC COMPENSATION; ACTIVE-FILTERS; SYSTEM;
D O I
10.1002/etep.1850
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A configuration consisting of a combination of a series active filter (APF) with a parallel passive filter has proven to be an efficient system for harmonic elimination of nonlinear loads. The most effective strategy for this configuration determines the APF reference voltage as the addition of two terms, the first proportional to the source current harmonics and the second opposite to the load voltage harmonics, current and voltage detection (CVD). To obtain the first term, an adequate adjustment of the proportionality constant k' is necessary for the implementation of the control algorithm. In this paper, design criteria to obtain the k values have been established, based on the system state model. Analysis of the resulting model provides the information needed to establish design criteria for the control strategy, both in terms of harmonic filtering and system stability. Finally, an experimental prototype was developed. The usefulness of the compensation equipment is experimentally confirmed in two contrasting situations: sinusoidal supply voltages and distorted supply voltages. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:419 / 432
页数:14
相关论文
共 50 条
  • [21] The new control strategy of shunt active power filter based on load current detection
    Jian, Y.-Z., 1600, Editorial Department of Electric Machines and Control (17):
  • [22] Current reference control for shunt active power filters under nonsinusoidal voltage conditions
    Petit, Johann F.
    Robles, Guillermo
    Amaris, Hortensia
    IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (04) : 2254 - 2261
  • [23] Coordinated Control Strategy of AC/DC Hybrid Power Router Based on Voltage Stabilization by Energy Storage
    Li Z.
    Sheng W.
    Duan Q.
    Li P.
    Wang J.
    Du S.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2019, 43 (02): : 121 - 129
  • [24] Control of series active power filters compensating for source voltage unbalance and current harmonics
    Lee, GM
    Lee, DC
    Seok, JK
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2004, 51 (01) : 132 - 139
  • [25] Control of series active power filters compensating for source voltage unbalance and current harmonics
    Lee, GM
    Lee, DC
    IECON'01: 27TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-3, 2001, : 1144 - 1149
  • [26] A new control design strategy for automatic voltage regulator in power system
    Sikander, Afzal
    Thakur, Padmanabh
    ISA TRANSACTIONS, 2020, 100 : 235 - 243
  • [27] Simplified control strategy for hybrid active filters
    Libano, FB
    Cobos, JA
    Uceda, J
    PESC'97: 28TH ANNUAL IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE - RECORD, VOLS I AND II, 1997, : 1102 - 1108
  • [28] Current control strategy of active power filter based on the indefinite frequency hysteresis space voltage vector
    College of Electric Power and Automation, Shanghai University of Electric Power, Shanghai 200090, China
    不详
    Dianji yu Kongzhi Xuebao, 1 (77-85):
  • [29] Control Strategy of High Voltage Ride Through for Adjusting Reactive Current Based on Transient Power Characteristics
    Li M.
    Wang B.
    Qu L.
    Tang Z.
    Yan S.
    Xu Q.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2020, 44 (06): : 59 - 66
  • [30] Current control strategy of injection type hybrid active power filter
    Qi, Ming-Jun
    Luo, An
    Liu, Ding-Guo
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2008, 28 (36): : 47 - 54