13N-ammonia positron emission tomography-derived left-ventricular strain in patients after heart transplantation validated using cardiovascular magnetic resonance feature tracking as reference

被引:5
作者
Kawakubo, Masateru [1 ]
Nagao, Michinobu [2 ]
Kikuchi, Noriko [3 ]
Yamamoto, Atsushi [2 ]
Nakao, Risako [3 ]
Matsuo, Yuka [2 ]
Kaneko, Koichiro [2 ]
Watanabe, Eri [3 ]
Sasaki, Masayuki [1 ]
Nunoda, Shinichi [4 ]
Sakai, Shuji [2 ]
机构
[1] Kyushu Univ, Fac Med Sci, Dept Hlth Sci, Fukuoka, Japan
[2] Tokyo Womens Med Univ, Dept Diagnost Imaging & Nucl Med, Shinjuku Ku, 8-1 Kawada Cho, Tokyo 1628666, Japan
[3] Tokyo Womens Med Univ, Dept Cardiol, Tokyo, Japan
[4] Tokyo Womens Med Univ, Grad Sch Med, Dept Therapeut Strategy Severe Heart Failure, Tokyo, Japan
基金
日本学术振兴会;
关键词
N-13-ammonia PET; Cardiac strain; Feature tracking; Cardiac magnetic resonance imaging; Heart transplantation; CARDIAC ALLOGRAFT VASCULOPATHY; EJECTION FRACTION; PROGNOSTIC VALUE; PET; ECHOCARDIOGRAPHY; ANGIOGRAPHY;
D O I
10.1007/s12149-021-01686-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective Heart transplant rejection leads to cardiac allograft vasculopathy (CAV). N-13-ammonia positron emission tomography (PET) can be useful in detecting CAV, as it can evaluate both epicardial vessels and microvasculature. In this study, we evaluated the regional wall motion in heart transplant patients using our PET-specific feature-tracking (FT) algorithm for myocardial strain calculation and validated it using a cardiovascular magnetic resonance (CMR) FT strain as a reference. Methods A total of 15 heart transplant patients who underwent both N-13-ammonia PET and CMR within 3 months were retrospectively enrolled. The same slice position of short-axis cine images of the middle slice of left ventricle (LV) and the same slice position of horizontal long-axis cine images were selected for the two modalities to measure the circumferential strain (CS) and longitudinal strain (LS), respectively. Based on the FT technique, time-strain curves were calculated by semi-automatic tracking of the endocardial contour on cine images throughout a cardiac cycle. The peak value in the time-strain curve was defined as the representative value. Correlations of CS and LS between PET and CMR were analyzed using Pearson correlation coefficients. The inter-modality error of strain measurements was evaluated using intraclass correlation coefficients (ICCs) with two-way random single measures. Results Excellent correlations of CS and LS between PET and CMR were observed (CS: r = 0.80; p < 0.01; LS: r = 0.87; p < 0.01). Excellent ICCs were observed (0.89 and 0.85) in CS and LS derived from PET. Conclusions We propose the first PET strain showing an excellent agreement with the CMR strain and high reproducibility in measurement.
引用
收藏
页码:70 / 81
页数:12
相关论文
共 27 条
[1]   Cardiac transplant vasculopathy [J].
Aranda, JM ;
Hill, J .
CHEST, 2000, 118 (06) :1792-1800
[2]   Diagnostic and prognostic value of myocardial blood flow quantification as non-invasive indicator of cardiac allograft vasculopathy [J].
Bravo, Paco E. ;
Bergmark, Brian A. ;
Vita, Tomas ;
Taqueti, Viviany R. ;
Gupta, Ankur ;
Seidelmann, Sara ;
Christensen, Thomas E. ;
Osborne, Michael T. ;
Shah, Nishant R. ;
Ghosh, Nina ;
Hainer, Jon ;
Bibbo, Courtney F. ;
Harrington, Meagan ;
Costantino, Fred ;
Mehra, Mandeep R. ;
Dorbala, Sharmila ;
Blankstein, Ron ;
Desai, Akshay ;
Stevenson, Lynne ;
Givertz, Michael M. ;
Di Carli, Marcelo F. .
EUROPEAN HEART JOURNAL, 2018, 39 (04) :316-323
[3]  
Carvajal-Juarez I., 2019, ANN NUCL CARDIOL, V5, P63, DOI [10.17996/anc.19-00100, DOI 10.17996/ANC.19-00100]
[4]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[5]  
Costanzo MR, 1998, J HEART LUNG TRANSPL, V17, P744
[6]   ASNC imaging guidelines/SNMMI procedure standard for positron emission tomography (PET) nuclear cardiology procedures [J].
Dilsizian, Vasken ;
Bacharach, Stephen L. ;
Beanlands, Rob S. ;
Bergmann, Steven R. ;
Delbeke, Dominique ;
Dorbala, Sharmila ;
Gropler, Robert J. ;
Knuuti, Juhani ;
Schelbert, Heinrich R. ;
Travin, Mark I. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2016, 23 (05) :1187-1226
[7]   Echocardiography and cardiovascular magnetic resonance based evaluation of myocardial strain and relationship with late gadolinium enhancement [J].
Erley, Jennifer ;
Genovese, Davide ;
Tapaskar, Natalie ;
Alvi, Nazia ;
Rashedi, Nina ;
Besser, Stephanie A. ;
Kawaji, Keigo ;
Goyal, Neha ;
Kelle, Sebastian ;
Lang, Roberto M. ;
Mor-Avi, Victor ;
Patel, Amit R. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2019, 21 (01)
[8]   Diagnostic accuracy of 13N-ammonia myocardial perfusion imaging with PET-CT in the detection of coronary artery disease [J].
Fathala, Ahmed ;
Aboulkheir, Mervat ;
Shoukri, Mohamamed M. ;
Alsergani, Hani .
CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2019, 9 (01) :35-42
[9]   Diagnostic Value of 13N-Ammonia Myocardial Perfusion PET: Added Value of Myocardial Flow Reserve [J].
Fiechter, Michael ;
Ghadri, Jelena R. ;
Gebhard, Catherine ;
Fuchs, Tobias A. ;
Pazhenkottil, Aju P. ;
Nkoulou, Rene N. ;
Herzog, Bernhard A. ;
Wyss, Christophe A. ;
Gaemperli, Oliver ;
Kaufmann, Philipp A. .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (08) :1230-1234
[10]  
Germano G, 1997, J NUCL MED, V38, P749