Intraocular pressure in American Bullfrogs (Rana catesbeiana) measured with rebound and applanation tonometry

被引:8
|
作者
Cannizzo, Sarah A. [1 ]
Lewbart, Gregory A. [1 ]
Westermeyer, Hans D. [1 ]
机构
[1] North Carolina State Univ, Coll Vet Med, Dept Clin Sci, 1060 William Moore Dr, Raleigh, NC 27607 USA
关键词
American Bullfrog; intraocular pressure; Rana catesbeiana; tonometry; Tono-Pen AVIA Vet (R); TonoVet (R); CORNEAL EPITHELIAL DEFECTS; DIAMOND BURR DEBRIDEMENT; SURGICAL-INSTRUMENTS; CONTACT-LENS; DOGS; EROSIONS; ULCERS; DISINFECTION; INFECTIONS; MANAGEMENT;
D O I
10.1111/vop.12463
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective To measure the intraocular pressure (IOP) in normal American Bullfrogs (Rana catesbeiana) with rebound and applanation tonometry and to create calibration curves for both tonometers to determine the actual IOP of bullfrogs. Procedures Twenty bullfrogs were evaluated with slip-lamp biomicroscopy, indirect ophthalmoscopy, rebound tonometry, and applanation tonometry. Axial globe length and corneal thickness were measured in the three largest and the three smallest frogs with ultrasonography and optical coherence tomography, respectively. Two frogs were euthanized for direct manometry. Results The median IOP was 4 mmHg with the rebound tonometer and 16 mmHg with the applanation tonometer. The correlation coefficient (r(2)) between the manometry measurements and the tonometers was 0.95 and 0.91 for the rebound and applanation tonometers, respectively. The corresponding equations were y = 0.331x + 0.558 for the rebound tonometer and y = 0.675x + 1.907 for the applanation tonometer. The median axial globe length was 0.94 cm. The median corneal thickness was 0.093 mm. Conclusions The rebound tonometer is the preferable tonometer for American Bullfrogs. Neither tonometer produced IOP readings that matched the manometer. The rebound tonometer was more precise and it was faster and easier to use.
引用
收藏
页码:526 / 532
页数:7
相关论文
共 50 条
  • [31] Differential impact of prostaglandin analogues on agreement of intraocular pressure measurements obtained by Goldmann applanation, rebound, and noncontact tonometry
    Jung, Younhea
    Suh, Hyun
    Moon, Jung Il
    BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [32] Effect of Repeated Applanation Tonometry on the Accuracy of Intraocular Pressure Measurements
    Gaton, Dan D.
    Ehrenberg, Miriam
    Lusky, Moshe
    Wussuki-Lior, Orly
    Dotan, Gad
    Weinberger, Dov
    Snir, Moshe
    CURRENT EYE RESEARCH, 2010, 35 (06) : 475 - 479
  • [33] EFFECTS OF ACCOMMODATION AND REPEATED APPLANATION TONOMETRY ON INTRAOCULAR-PRESSURE
    MAUGER, RR
    LIKENS, CP
    APPLEBAUM, M
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1984, 61 (01): : 28 - 30
  • [34] Effect of Repeated Applanation Tonometry on the Accuracy of Intraocular Pressure Measurements
    Ehrenberg, M.
    Gaton, D.
    Lusky, M.
    Dotan, G.
    Weinberger, D.
    Snir, M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [36] Assessment of intraocular pressure measured by Reichert Ocular Response Analyzer, Goldmann Applanation Tonometry, and Dynamic Contour Tonometry in healthy individuals
    Ouyang, Ping-Bo
    Li, Cong-Yi
    Zhu, Xiao-Hua
    Duan, Xuan-Chu
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2012, 5 (01) : 102 - 107
  • [37] Properties associated with intraocular pressure dissonance as measured by Goldman Applanation Tonometry compared to the Ocular Response Analyzer
    Johnson, Matthew C.
    Kang, Joyce
    Zhao, Yan
    Lin, Michael M.
    Friedman, David S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [38] Validation of rebound tonometry for intraocular pressure measurement in the rabbit
    Zhang, Hong
    Yang, Dong
    Ross, Craig M.
    Wigg, Jonathan P.
    Pandav, Surinder
    Crowston, Jonathan G.
    EXPERIMENTAL EYE RESEARCH, 2014, 121 : 86 - 93
  • [39] Identification and Characterization of Klebsiella pneumoniae from Farmed American Bullfrogs (Rana catesbeiana)
    Lin, Han
    Ma, Jie
    Sun, Jingyang
    Qin, Zhendong
    Jiang, Biao
    Li, Wei
    Wang, Qing
    Su, Youlu
    Lin, Li
    Liu, Chun
    MICROBIOLOGY SPECTRUM, 2023, 11 (01):
  • [40] Dynamic contour tonometry and Goldmann applanation tonometry: correlation with intracameral assessment of intraocular pressure
    Riva, Ivano
    Quaranta, Luciano
    Russo, Andrea
    Katsanos, Andreas
    Rulli, Eliana
    Floriani, Irene
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2012, 22 (01) : 55 - 62