Time Synchronization for Smart Grids Applications: Requirements and Uncertainty Issues

被引:8
作者
Macii, David [1 ]
Rinaldi, Stefano [2 ]
机构
[1] Univ Trento, Dept Ind Engn, Trento, Italy
[2] Univ Brescia, Dept Informat Engn, Brescia, Italy
关键词
Time-frequency analysis; Uncertainty; Phase measurement; Voltage measurement; Phasor measurement units; Frequency measurement; Smart grids;
D O I
10.1109/MIM.2022.9847197
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Smart grid implementation requires that multiple distributed systems are synchronized within and between substations. This is needed to coordinate the Intelligent Electronic Devices (IEDs) as well as to align in time the measurement data associated with the same event, but collected in different points of a broad geographical area. The time synchronization accuracy requirements in power systems are application-specific and are classified in the IEC Standard 61850-5:2013. Depending on such requirements, alternative solutions can be used. For instance, sub-microsecond time synchronization is essential for the implementation of Wide Area Monitoring, Protection, and Control (WAMPAC) systems. In fact, time synchronization directly and indirectly affects Phasor Measurement Units (PMUs) accuracy. The PMUs can measure the magnitude, the phase, the fundamental frequency and the Rate of Change of Frequency (ROCOF) of ac voltage and current waveforms at times synchronized to the Universal Coordinated Time (UTC). Among such quantities, the phase data are those most strongly affected by time synchronization. If time synchronization accuracy is within +/- 1 mu s, its impact on synchrophasor phase measurement is in the order of a fraction of mrad, i.e., low enough to have a negligible impact on the state estimation uncertainty of most of transmission and distribution systems. However, the need to interpolate the missing phasor values when data from PMUs with a different reporting rate are collected and aligned in time may unexpectedly boost synchrophasor phase estimation uncertainty.
引用
收藏
页码:11 / 18
页数:8
相关论文
共 10 条
[1]  
[Anonymous], 2013, IEC 61850-5
[2]  
[Anonymous], 2018, Standard IEC/IEEE 60255-118-1, DOI DOI 10.1109/IEEESTD.2018.8577045
[3]  
[Anonymous], 2008, 15882008 IEEE, P1
[4]   Electrical Distribution System State Estimation: Measurement Issues and Challenges [J].
Della Giustina, Davide ;
Pau, Marco ;
Pegoraro, Paolo Attilio ;
Ponci, Ferdinanda ;
Sulis, Sara .
IEEE INSTRUMENTATION & MEASUREMENT MAGAZINE, 2014, 17 (06) :36-42
[5]   The White Rabbit Time Synchronization Protocol for Synchrophasor Networks [J].
Derviskadic, Asja ;
Razzaghi, Reza ;
Walger, Quentin ;
Paolone, Mario .
IEEE TRANSACTIONS ON SMART GRID, 2020, 11 (01) :726-738
[6]  
IEC/IEEE International Standard, 2016, 6185093 IECIEEE, P1
[7]  
Phadke A.G., 2010, SYNCHRONIZED PHASOR
[8]   White Rabbit Clock Synchronization: Ultimate Limits on Close-In Phase Noise and Short-Term Stability Due to FPGA Implementation [J].
Rizzi, Mattia ;
Lipinski, Maciej ;
Ferrari, Paolo ;
Rinaldi, Stefano ;
Flammini, Alessandra .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2018, 65 (09) :1726-1737
[9]   GPS-Disciplined Analog-to-Digital Converter for Phasor Measurement Applications [J].
Zhao, Xiaodong ;
Laverty, David M. ;
McKernan, Adrian ;
Morrow, D. John ;
McLaughlin, Kieran ;
Sezer, Sakir .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2017, 66 (09) :2349-2357
[10]   MATPOWER: Steady-State Operations, Planning, and Analysis Tools for Power Systems Research and Education [J].
Zimmerman, Ray Daniel ;
Edmundo Murillo-Sanchez, Carlos ;
Thomas, Robert John .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2011, 26 (01) :12-19