Compressed-sensing-based three-dimensional image reconstruction algorithm for C-arm vascular imaging

被引:0
|
作者
Selim, Mona [1 ,4 ]
al-Shatouri, Mohammad [2 ]
Kudo, Hiroyuki [3 ]
Rashed, Essam A. [4 ]
机构
[1] Suez Univ, Fac Sci, Math & Comp Sci Dept, Suez, Egypt
[2] Suez Canal Univ, Dept Radiol, Fac Med, Ismailia, Egypt
[3] Univ Tsukuba, Dept Comp Sci, Tsukuba, Ibaraki, Japan
[4] Suez Canal Univ, Dept Math, Image Sci Lab, Fac Sci, Ismailia, Egypt
来源
2014 CAIRO INTERNATIONAL BIOMEDICAL ENGINEERING CONFERENCE (CIBEC) | 2014年
关键词
Image reconstruction; computed tomography; 3D C-arm CT; ADMM; PROJECTIONS; DETECTOR;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
X-ray C-arm is an important imaging tool in interventional surgery, road-mapping and radiation therapy. It provides accurate description of vascular anatomy and therapy end point. The C-arm scanner produces two-dimensional (2D) x-ray projection data obtained with flat-panel detector by rotating the source around the patient. The number of 2D projections acquired is several hundreds, which results in significant amount of radiation dose. Unlike the conventional fluoroscopic imaging, three-dimensional (3D) C-arm computed tomography (CT) provides more accurate cross-sectional images which are valuable for therapy planning, guidance and evaluation in interventional radiology. However, 3D vascular imaging using the conventional C-arm fluoroscopy is a challenging task. First, the rotation orbit of the C-arm gantry is usually limited to a range less than those of CT scanners. Second, in several commercial models (including the one of consideration in this study), the x-ray source and detector are shifted from the gantry isocenter to enlarge the scanner field-of-view (FOV), which is so-called the offset scan. Finally, it is difficult to acquire sufficient projection views required for stable 3D reconstruction using manually controlled gantry motion. Inspired by the theory of compressed sensing, we developed an image reconstruction algorithm for the conventional angiography C-arm scanners. The main challenge in this image reconstruction problem is the projection data limitations. We consider a small number of views (less than 10 views) acquired from a short orbit with the offset scan geometry. The proposed method is developed using the alternating direction method of multipliers (ADMM) and results obtained from simulated data and real data are encouraging. The proposed method can significantly contribute to the reduction of patient dose and provides a framework to generate 3D vascular images using the conventional C-arm scanners.
引用
收藏
页码:111 / 114
页数:4
相关论文
共 50 条
  • [31] Towards Clinical Application of a Laplace Operator-Based Region of Interest Reconstruction Algorithm in C-Arm CT
    Xia, Yan
    Hofmann, Hannes
    Dennerlein, Frank
    Mueller, Kerstin
    Schwemmer, Chris
    Bauer, Sebastian
    Chintalapani, Gouthami
    Chinnadurai, Ponraj
    Hornegger, Joachim
    Maier, Andreas
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (03) : 593 - 606
  • [32] Fully three-dimensional OSEM-based image reconstruction for Compton imaging using optimized ordering schemes
    Kim, Soo Mee
    Lee, Jae Sung
    Lee, Chun Sik
    Kim, Chan Hyeong
    Lee, Myung Chul
    Lee, Dong Soo
    Lee, Soo-Jin
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (17) : 5007 - 5027
  • [33] Use of a C-arm system to generate true three-dimensional computed rotational angiograms: Preliminary in vitro and in vivo results
    Fahrig, R
    Fox, AJ
    Lownie, S
    Holdsworth, DW
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1997, 18 (08) : 1507 - 1514
  • [34] Low-dose Cone-Beam Computed Tomography Reconstruction through a fast Three-Dimensional Compressed Sensing Method Based on the Three-Dimensional Pseudo-polar Fourier Transform
    Teyfouri, N.
    Rabbani, Hossein
    Jabbari, I
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2022, 12 (01): : 8 - 24
  • [35] Three-Dimensional Characterization of Iron Oxide (α-Fe2O3) Nanoparticles: Application of a Compressed Sensing Inspired Reconstruction Algorithm to Electron Tomography
    Monsegue, Niven
    Jin, Xin
    Echigo, Takuya
    Wang, Ge
    Murayama, Mitsuhiro
    MICROSCOPY AND MICROANALYSIS, 2012, 18 (06) : 1362 - 1367
  • [36] Accurate Model-Based Reconstruction Algorithm for Three-Dimensional Optoacoustic Tomography
    Dean-Ben, X. Luis
    Buehler, Andreas
    Ntziachristos, Vasilis
    Razansky, Daniel
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (10) : 1922 - 1928
  • [37] A three-dimensional image reconstruction algorithm for electrical impedance tomography using planar electrode arrays
    Perez, Husein
    Pidcock, Michael
    Sebu, Cristiana
    INVERSE PROBLEMS IN SCIENCE AND ENGINEERING, 2017, 25 (04) : 471 - 491
  • [38] Compressive Sensing-Based Three-Dimensional Laser Imaging With Dual Illumination
    An, Yulong
    Zhang, Yanmei
    Guo, Haichao
    Wang, Jing
    IEEE ACCESS, 2019, 7 : 25708 - 25717
  • [39] Development of a new three-dimensional image reconstruction algorithm to reduce cone-beam artifacts
    Gomi, T
    Koshida, K
    Miyati, T
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 1046 - 1056
  • [40] A WEIGHTED FILTERED BACK PROJECTION ALGORITHM FOR LOG CT TWO-DIMENSIONAL AND THREE-DIMENSIONAL IMAGE RECONSTRUCTION
    Xu Jiahe
    Zhou Yucheng
    Qi Yuhan
    Hou Xiaopeng
    WOOD RESEARCH, 2016, 61 (06) : 971 - 982