Two-year follow-up of noncontact holmium laser thermokeratoplasty for the correction of low hyperopia

被引:6
作者
Rocha, G
Castillo, JM
Sánchez-Thorin, JC
Johnston, J
Cartagena, RG
机构
[1] Univ Manitoba, Brandon Reg Hlth Ctr, Brandon, MB, Canada
[2] Univ Ottawa, Inst Eye, Ottawa, ON, Canada
[3] Hosp San Jose Monterrey ITESM, Dept Ophthalmol, Monterrey, Mexico
[4] Fdn Santa Fe Bogota, Dept Ophthalmol, Bogota, Colombia
[5] Brandon Univ, Dept Sci, Brandon, MB, Canada
来源
CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE | 2003年 / 38卷 / 05期
关键词
hyperopia; holmium : YAG laser; holmium laser thermokeratoplasty; keratomileusis;
D O I
10.1016/S0008-4182(03)80050-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To summarize the 2-year results of laser thermal keratoplasty with a holmium:yttrium-aluminum-garnet (Ho:YAG) laser and the Sunrise Corneal Shaping System and assess the procedure's safety, efficacy and predictability in correcting hyperopia in a phase III clinical intervention case series. Methods: The Ho:YAG laser was used to correct low hyperopia (manifest spherical equivalent of +0.75 to +2.50 dioptres [D], with manifest cylinder of 1.00 D or less) in 38 eyes of 28 patients 40 years of age or older. Laser pulses were delivered to the cornea in 2 radially placed, concentric, 8-spot rings 6.0 and 7.0 mm in diameter. The last follow-up was at 2 years. Results: The preoperative uncorrected visual acuity (UCVA) at distance was less than 20/40 in 82% of the eyes and at near was less than 20/32 in 42%. At 2 years the distance UCVA was 20/40 or better in 100% of the eyes and 20/20 or better in 84%, and the near UCVA was 20/32 or better in 97% of the eyes and 20/20 or better in 8%. The difference between the preoperative and postoperative UCVA was statistically significant (p < 0.01). The correction at 2 years was within 0.50 D of that intended in 92% of the eyes and within 1.00 D in 100%. The reduction in mean spherical equivalent at 2 years was statistically significant (p < 0.0001). No loss of 2 lines or more in best-corrected visual acuity occurred after the 1 st month of follow-up. Interpretation: The Ho:YAG Sunrise Corneal Shaping System is safe and effective for the treatment of low hyperopia and astigmatism. It provides a predictable refractive outcome at 2 years of follow-up. However, our results show a tendency towards regression by 2 years.
引用
收藏
页码:385 / 392
页数:8
相关论文
共 12 条
  • [1] Alio JL, 1997, J REFRACT SURG, V13, P17
  • [2] Histologic analysis of thermal effects of laser thermokeratoplasty and corneal ablation using Sirius-red polarization microscopy
    AsiyoVogel, MN
    Brinkmann, R
    Notbohm, H
    Eggers, R
    Lubatschowski, H
    Laqua, H
    Vogel, A
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (04) : 515 - 526
  • [3] AYALA MJ, 2000, ARCH SOC ESP OFTALMO, V75, P619
  • [4] Gezer A, 1997, Eur J Ophthalmol, V7, P139
  • [5] Hyperopia correction by noncontact holmium: YAG laser thermal keratoplasty - US phase IIA clinical study with 2-year follow-up
    Koch, DD
    Kohnen, T
    McDonnell, PJ
    Menefee, R
    Berry, M
    [J]. OPHTHALMOLOGY, 1997, 104 (11) : 1938 - 1947
  • [6] Koch DD, 1996, J REFRACT SURG, V12, P623
  • [7] Koch DD, 1996, OPHTHALMOLOGY, V103, P731
  • [8] Corneal topographic changes after noncontact holmium:YAG laser thermal keratoplasty to correct hyperopia
    Kohnen, T
    Husain, SE
    Koch, DD
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (04) : 427 - 435
  • [9] MOREIRA H, 1993, OPHTHALMOLOGY, V100, P752
  • [10] Noncontact holmium:YAG laser thermal keratoplasty for hyperopia
    Nano, HD
    Muzzin, S
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (06) : 751 - 757