Ergonomic port placement in robotic colorectal surgery

被引:5
|
作者
Wong, Shing Wai [1 ,2 ]
Ang, Zhen Hao [1 ,2 ]
Chua, Jia Lin [3 ]
Crowe, Philip [1 ,2 ]
机构
[1] Prince Wales Hosp, Dept Gen Surg, Sydney, NSW, Australia
[2] Univ New South Wales, Prince Wales Clin Sch, Sydney, NSW, Australia
[3] Westmead Hosp, Dept Radiol, Sydney, NSW, Australia
关键词
ergonomics; port placement; robotic colorectal surgery; MANIPULATION ANGLE;
D O I
10.1111/codi.15804
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Aim The aim of the study was to determine how spacing between ports and alignment of ports (oblique or vertical) influences manipulation angles in robotic colorectal surgery. Method Abdominal CT scans of 10 consecutive robotic right hemicolectomy and 10 consecutive robotic high anterior resection patients were analysed. The manipulation angles were calculated using fixed points on the preoperative abdominal coronal CT scan. Port placements were marked on the CT scan. The fixed points used to measure the manipulation angles were from the most lateral part of the caecum, hepatic flexure, splenic flexure, the descending colon/sigmoid colon junction and the sigmoid colon/rectum junction. Results For right hemicolectomy and high anterior resection surgery, a port spacing of 8 cm compared with 6 cm resulted in greater manipulation angles. With 6-cm port spacing, wider manipulation angles were not achieved with vertical port alignment compared with oblique alignment except for dissection at the splenic flexure. Conclusions The greatest manipulation angles were achieved with the oblique 8-cm port spacing, which should be used in most cases.
引用
收藏
页码:2593 / 2603
页数:11
相关论文
共 50 条
  • [31] Robotic Mediastinal Tumor Resections: Position and Port Placement
    Okazaki, Mikio
    Shien, Kazuhiko
    Suzawa, Ken
    Sugimoto, Seiichiro
    Toyooka, Shinichi
    JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (08):
  • [32] Straight-arm positioning and port placement for pediatric robotic-assisted laparoscopic renal surgery
    Chandrasoma S.
    Kokorowski P.
    Peters C.A.
    Koh C.J.
    Journal of Robotic Surgery, 2010, 4 (1) : 29 - 32
  • [33] A PHASE II CLINICAL TRIAL OF SINGLE-PORT ROBOTIC (SPR) COLORECTAL SURGERY.
    Marks, J.
    Yang, J.
    Salem, J.
    Spitz, E.
    Kosinski, L.
    Schoonyoung, H.
    DISEASES OF THE COLON & RECTUM, 2022, 65 (05) : 16 - 17
  • [34] Optimal Port Placement could Improve the Ergonomic Design of Laparoscope Manipulating Robot
    Khampitak, Kovit
    Wattanachai, Suchat
    Kunkitti, Panisara
    Kumpa, Naruepon
    Techajedchadarungsri, Sirivit
    Samsong, Papada
    Khampitak, Tueanjit
    Seejorn, Kanok
    INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS 2010), 2010, : 147 - 150
  • [35] Robotic Colorectal Surgery for Neoplasia
    Pai, Ajit
    Marecik, Slawomir
    Park, John
    Prasad, Leela
    SURGICAL CLINICS OF NORTH AMERICA, 2017, 97 (03) : 561 - +
  • [36] Robotic Surgery for Colorectal Cancer
    Shah, Muhammad Fahd
    Nasir, Irfan ul Islam
    Parvaiz, Amjad
    VISCERAL MEDICINE, 2019, 35 (04) : 247 - 250
  • [37] Introduction: Robotic colorectal surgery
    Fleshman, James
    SEMINARS IN COLON AND RECTAL SURGERY, 2016, 27 (03) : 119 - 120
  • [38] Robotic surgery for colorectal cancer
    Matsuda, Chu
    Adachi, Yosuke
    ANNALS OF GASTROENTEROLOGICAL SURGERY, 2017, 1 (01): : 75 - 75
  • [39] Troubleshooting in Robotic Colorectal Surgery
    Giulianotti, Pier C.
    Bianco, Francesco M.
    Addeo, Pietro
    SEMINARS IN COLON AND RECTAL SURGERY, 2009, 20 (04) : 195 - 200
  • [40] Value of robotic colorectal surgery
    Jensen, C. C.
    Madoff, R. D.
    BRITISH JOURNAL OF SURGERY, 2016, 103 (01) : 12 - 13