Direct determination of aluminium in foods and pharmaceutical preparations by potentiometry using an AlMCM-41 modified polymeric membrane sensor

被引:24
作者
Arvand, Majid [1 ]
Kermanian, Maryam [1 ]
Zanjanchi, Mohammad A. [1 ]
机构
[1] Univ Guilan, Dept Chem, Fac Sci, Rasht, Iran
关键词
Aluminium; Zeolite modified electrodes; AlMCM-41; Food products; Potentiometry; ZEOLITE-MODIFIED ELECTRODES; CARBON-PASTE ELECTRODE; POLY(VINYL CHLORIDE) MATRIX; ION-SELECTIVE ELECTRODE; SYNTHETIC ZEOLITE; NEUTRAL-CARRIER; SCHIFF-BASE; ALZHEIMERS-DISEASE; METAL-IONS; WATER;
D O I
10.1016/j.electacta.2010.06.083
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A potentiometric aluminium sensor, based on the use AlMCM-41 as a neutral carrier, in poly(vinyl chloride) (PVC) matrix, is reported. The sensor exhibits significantly enhanced selectivity toward Al3+ ions over the concentration range 1.0 x 10(-7) to 1.0 x 10(-1) M with a detection limit of 8.6 x 10(-8) M and a Nernstian slope of 19.5 +/- 0.4 mV/decade of activity. The best performance was obtained with membrane composition 30% poly(vinyl chloride), 67% acetophenone, 3% ionophore and 2 mL tetrahydrofuran. Fast and stable response, good reproducibility and long-term stability are demonstrated. The response time of the sensor is similar to 10s and membrane could be used over a period of 3 months without any considerable divergence in potentials. Selectivity coefficients were determined by matched potential method (MPM). The AIMCM-41-based sensor is suitable for use in aqueous solution of pH 3-6. The standard electrode potentials were determined at different temperatures and used to calculate the isothermal coefficient of the electrode. It was used to determine Al3+ in drugs and food products. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:6946 / 6952
页数:7
相关论文
共 62 条
  • [1] ABBASI S, 2009, FOOD CHEM, V117, P3
  • [2] Aluminium(III)-selective electrode based on a newly synthesized tetradentate Schiff base
    Abbaspour, A
    Esmaeilbeig, AR
    Jarrahpour, AA
    Khajeh, B
    Kia, R
    [J]. TALANTA, 2002, 58 (02) : 397 - 403
  • [3] Abel-Ghany M., 1976, J BIOL CHEM, V268, P976
  • [4] Tin(II)-selective membrane potentiometric sensor using a crown ether as neutral carrier
    Aghaie, H
    Giahi, A
    Monajjemi, M
    Arvand, A
    Nafissi, GH
    Aghaie, M
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2005, 107 (02) : 756 - 761
  • [5] Reverse flow-injection manifold for spectrofluorimetric determination of aluminum in drinking water
    Albendín, G
    Mánuel-Vez, MP
    Moreno, C
    García-Vargas, M
    [J]. TALANTA, 2003, 60 (2-3) : 425 - 431
  • [6] Antropov L.I., 1972, THEORETICAL ELECTROC
  • [7] Ion-selective electrode for aluminum determination in pharmaceutical substances, tea leaves and water samples
    Arvand, M.
    Asadollahzadeh, S. A.
    [J]. TALANTA, 2008, 75 (04) : 1046 - 1054
  • [8] Novel thiocyanate-selective membrane sensor based on crown ether-cetyltrimethyl ammonium thiocyanate ion-pair as a suitable ionophore
    Arvand, M.
    Zanjanchi, M. A.
    Heydari, L.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2007, 122 (01): : 301 - 308
  • [9] A PTEV-based zeolite membrane potentiometric sensor for cesium ion
    Arvand-Barmchi, M
    Mousavi, MF
    Zanjanchi, MA
    Shamsipur, M
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2003, 96 (03) : 560 - 564
  • [10] Babenikov V, 2005, J ANAL CHEM+, V60, P866