Analysis of Pulse Arrival Time as an Indicator of Blood Pressure in a Large Surgical Biosignal Database: Recommendations for Developing Ubiquitous Blood Pressure Monitoring Methods

被引:35
作者
Lee, Joonnyong [1 ]
Yang, Seungman [2 ]
Lee, Saram [1 ]
Kim, Hee Chan [3 ,4 ]
机构
[1] Seoul Natl Univ Hosp, Biomed Res Inst, Seoul 03080, South Korea
[2] Seoul Natl Univ, Interdisciplinary Program Bioengn, Grad Sch, Seoul 03080, South Korea
[3] Seoul Natl Univ, Coll Med, Dept Biomed Engn, Seoul 03080, South Korea
[4] Seoul Natl Univ, Med Res Ctr, Inst Med & Biol Engn, Seoul 03080, South Korea
基金
新加坡国家研究基金会;
关键词
blood pressure monitoring; pulse arrival time; pulse transit time; pulse wave velocity; biosignal database; ubiquitous healthcare; hypertension; cardiovascular monitoring; TRANSIT-TIME; WAVE VELOCITY; ARTERIAL STIFFNESS; RISK-FACTORS; CUFF-LESS; POPULATION; EPIDEMIOLOGY; VARIABILITY; ALGORITHMS; DISEASE;
D O I
10.3390/jcm8111773
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
As non-invasive continuous blood pressure monitoring (NCBPM) has gained wide attraction in the recent decades, many pulse arrival time (PAT) or pulse transit time (PTT) based blood pressure (BP) estimation studies have been conducted. However, most of the studies have used small homogeneous subject pools to generate models of BP based on particular interventions for induced hemodynamic change. In this study, a large open biosignal database from a diverse group of 2309 surgical patients was analyzed to assess the efficacy of PAT, PTT, and confounding factors on the estimation of BP. After pre-processing the dataset, a total of 6,777,308 data pairs of BP and temporal features between electrocardiogram (ECG) and photoplethysmogram (PPG) were extracted and analyzed. Correlation analysis revealed that PAT or PTT extracted from the intersecting-tangent (IT) point of PPG showed the highest mean correlation to BP. The mean correlation between PAT and systolic blood pressure (SBP) was -0.37 and the mean correlation between PAT and diastolic blood pressure (DBP) was -0.30, outperforming the correlation between BP and PTT at -0.12 for SBP and -0.11 for DBP. A linear model of BP with a simple calibration method using PAT as a predictor was developed which satisfied international standards for automatic oscillometric BP monitors in the case of DBP, however, SBP could not be predicted to a satisfactory level due to higher errors. Furthermore, multivariate regression analyses showed that many confounding factors considered in previous studies had inconsistent effects on the degree of correlation between PAT and BP.
引用
收藏
页数:19
相关论文
共 68 条
[1]   Arterial stiffness and cardiovascular risk factors in a population-based study [J].
Amar, J ;
Ruidavets, JB ;
Chamontin, B ;
Drouet, L ;
Ferrières, J .
JOURNAL OF HYPERTENSION, 2001, 19 (03) :381-387
[2]  
[Anonymous], COMM TREATM DRUG
[3]  
[Anonymous], SP101992A1 ANSIAAMI
[4]  
[Anonymous], 2014, IEEE Std 1708-2014, P1, DOI [10.1109/IEEESTD.2014.6882122, DOI 10.1109/IEEESTD.2014.6882122]
[5]  
ARMITAGE P, 1966, CLIN SCI, V30, P325
[6]   Validity of transit time-based blood pressure measurements in patients with and without heart failure or pulmonary arterial hypertension across different breathing maneuvers [J].
Becker, Sara ;
Spiesshoefer, Jens ;
Brix, Tobias ;
Tuleta, Izabela ;
Mohr, Michael ;
Emdin, Michele ;
Boentert, Matthias ;
Giannoni, Alberto .
SLEEP AND BREATHING, 2020, 24 (01) :221-230
[8]   PREVALENCE OF HYPERTENSION IN THE US ADULT-POPULATION - RESULTS FROM THE 3RD NATIONAL-HEALTH AND NUTRITION EXAMINATION SURVEY, 1988-1991 [J].
BURT, VL ;
WHELTON, P ;
ROCCELLA, EJ ;
BROWN, C ;
CUTLER, JA ;
HIGGINS, M ;
HORAN, MJ ;
LABARTHE, D .
HYPERTENSION, 1995, 25 (03) :305-313
[9]   Cuffless Differential Blood Pressure Estimation Using Smart Phones [J].
Chandrasekaran, Vikram ;
Dantu, Ram ;
Jonnada, Srikanth ;
Thiyagaraja, Shanti ;
Subbu, Kalyan Pathapati .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (04) :1080-1089
[10]   Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration [J].
Chen, W ;
Kobayashi, T ;
Ichikawa, S ;
Takeuchi, Y ;
Togawa, T .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (05) :569-574