Hydrophilic polymer emboli: an under-recognized iatrogenic cause of ischemia and infarct

被引:108
作者
Mehta, Rupal I. [1 ]
Mehta, Rashi I. [1 ]
Solis, Orestes E. [1 ]
Jahan, Reza [2 ]
Salamon, Noriko [3 ]
Tobis, Jonathan M. [4 ]
Yong, William H. [1 ]
Vinters, Harry V. [1 ,5 ]
Fishbein, Michael C. [6 ]
机构
[1] Univ Calif Los Angeles, Dept Pathol & Lab Med, Sect Neuropathol, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Dept Intervent Neuroradiol, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, Dept Radiol Sci, Los Angeles, CA 90095 USA
[4] Univ Calif Los Angeles, Dept Med, Div Cardiol, Los Angeles, CA 90095 USA
[5] Univ Calif Los Angeles, Brain Res Inst, Mental Retardat Res Ctr, Dept Neurol, Los Angeles, CA 90024 USA
[6] Univ Calif Los Angeles, Dept Pathol & Lab Med Autopsy & Cardiopulm Pathol, Los Angeles, CA 90095 USA
关键词
hydrophilic polymer; interventional procedure; catheter; guidewire; pulmonary infarct; cerebral infarct; HYDROGEL-COATED COILS; TRANSRADIAL CATHETERIZATION; INTRACRANIAL ANEURYSMS; STERILE INFLAMMATION; COMPLICATIONS; MENINGITIS;
D O I
10.1038/modpathol.2010.74
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
With the increased use of percutaneous intravascular diagnostic and therapeutic devices, there is potential for embolization of materials introduced into the vasculature. We report nine cases of foreign body emboli in patients who underwent vascular procedures using hydrophilic-coated medical devices. The procedures performed included cardiac catheterization (four cases), diagnostic cerebral angiography (two cases), therapeutic cerebral angiography with coil embolization of intracerebral aneurysm (one case), lower extremity angiography (one case), and/or orthotopic cadaveric organ transplantation (three cases). Other procedures in these patients included hemodialysis and peripheral arterial or central venous catheterization. Clinical sequelae ranged from undetectable (no symptoms) to pulmonary infarction, stroke, ongoing gangrene, and/or death occurring within days to weeks of suspected embolization of foreign material. Microscopic findings in biopsy or autopsy tissue revealed aggregates of amorphous or lamellated, non-refractile, non-polarizable, predominantly basophilic foreign substances occluding intrapulmonary, intracerebral, or peripheral arteries. This is the largest series documenting embolization of polymer gel materials. Polymer gel is now widely used on several devices for interventional procedures worldwide, and we suspect that complications associated with iatrogenic embolization of this substance are under-recognized. Modern Pathology (2010) 23, 921-930; doi:10.1038/modpathol.2010.74; published online 19 March 2010
引用
收藏
页码:921 / 930
页数:10
相关论文
共 21 条
[1]   Embolization of Hydrophilic Catheter Coating to the Lungs Report of a Case Mimicking Granulomatous Vasculitis [J].
Allan, Robert W. ;
Alnuaimat, Hassan ;
Edwards, William D. ;
Tazelaar, Henry D. .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2009, 132 (05) :794-797
[2]  
[Anonymous], INT J CARDIOL
[3]  
Barnwell SL, 1997, AM J NEURORADIOL, V18, P1886
[4]   A comparison of two antimicrobial-impregnated central venous catheters [J].
Darouiche, RO ;
Raad, II ;
Heard, SO ;
Thornby, JI ;
Wenker, OC ;
Gabrielli, A ;
Berg, J ;
Khardori, N ;
Hanna, H ;
Hachem, R ;
Harris, RL ;
Mayhall, G .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 340 (01) :1-8
[5]   Complications of endovascular polymers associated with vascular introducer sheaths and metallic coils in 3 patients, with literature review [J].
Fealey, Michael E. ;
Edwards, William D. ;
Giannini, Caterina ;
Piepgras, David G. ;
Cloft, Harry ;
Rihal, Charanjit S. .
AMERICAN JOURNAL OF SURGICAL PATHOLOGY, 2008, 32 (09) :1310-1316
[6]   Embolization of intracranial aneurysms with hydrogel-coated coils versus inert platinum coils - Effects on packing density, coil length and quantity, procedure performance, cost, length of hospital stay, and durability of therapy [J].
Gaba, RC ;
Ansari, SA ;
Roy, SS ;
Marden, FA ;
Viana, MAG ;
Malisch, TW .
STROKE, 2006, 37 (06) :1443-1450
[7]  
Im SH, 2007, AM J NEURORADIOL, V28, P511
[8]   Sterile inflammation associated with transradial catheterization and hydrophilic sheaths [J].
Kozak, M ;
Adams, DR ;
Ioffreda, MD ;
Nickolaus, MJ ;
Seery, TJ ;
Chambers, CE ;
Ettinger, SM ;
McNulty, PH ;
Gilchrist, IC .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 59 (02) :207-213
[9]  
Lechpammer M, 2009, J NEUROPATH EXP NEUR, V68, P578
[10]   Stenting in acute coronary syndromes: A comparison of radial versus femoral access sites [J].
Mann, T ;
Cubeddu, G ;
Bowen, J ;
Schneider, JE ;
Arrowood, M ;
Newman, WN ;
Zellinger, MJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (03) :572-576