Impact of the Learning Curve for Endoscopic Vein Harvest on Conduit Quality and Early Graft Patency

被引:62
作者
Desai, Pranjal
Kiani, Soroosh
Thiruvanthan, Nannan
Henkin, Stanislav
Kurian, Dinesh
Ziu, Pluen
Brown, Alex
Patel, Nisarg
Poston, Robert [1 ]
机构
[1] Univ Arizona, Dept Surg, Sch Med, Div Cardiothorac Surg, Tucson, AZ 85724 USA
关键词
ARTERY-BYPASS SURGERY; OPTICAL COHERENCE TOMOGRAPHY; INTERNAL MAMMARY ARTERY; CORONARY-ARTERY; SAPHENOUS-VEIN; RANDOMIZED-TRIAL; RADIAL ARTERY; INJURY; PREVENTION; OUTCOMES;
D O I
10.1016/j.athoracsur.2011.01.079
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Recent studies have suggested that endoscopic vein harvest (EVH) compromises graft patency. To test whether the learning curve for EVH alters conduit integrity owing to increased trauma compared with an open harvest, we analyzed the quality and early patency of conduits procured by technicians with varying EVH experience. Methods. During coronary artery bypass grafting, veins were harvested open (n = 10) or by EVH (n = 85) performed by experienced (>900 cases, >30/month) versus novice <100 cases, <3/month) technicians. Harvested conduits were imaged intraoperatively using optical coherence tomography and on day 5 to assess graft patency using computed tomographic angiography. Results. Conduits from experienced (n = 55) versus novice (n = 30) harvesters had similar lengths (33 versus 34 cm) and harvest times (32.4 versus 31.8 minutes). Conduit injury was noted in both EVH groups with similar distribution among disruption of the adventitia (62%), intimal tears at branch points (23%), and intimal or medial dissections (15%), but the incidence of these injuries was less with experienced harvesters and rare in veins procured with an open technique. Overall, the rate of graft attrition was similar between the two EVH groups (6.45% versus 4.34% of grafts; p = 0.552). However, vein grafts with at least 4 intimal or medial dissections showed significantly worse patency (67% versus 96% patency; p = 0.05). Conclusions. High-resolution imaging confirmed that technicians inexperienced with EVH are more likely to cause intimal and deep vessel injury to the saphenous vein graft, which increases graft failure risk. Endoscopic vein harvest remains the most common technique for conduit harvest, making efforts to better monitor the learning curve an important public health issue. (Ann Thorac Surg 2011; 91: 1385-92) (C) 2011 by The Society of Thoracic Surgeons
引用
收藏
页码:1385 / 1391
页数:7
相关论文
共 33 条
[21]   In vitro comparison of glyceryl trinitrate-verapamil with other dilators of human saphenous vein [J].
Jesuthasan, LSB ;
Angus, JA ;
Rosenfeldt, FL .
ANZ JOURNAL OF SURGERY, 2003, 73 (05) :313-320
[22]   Endoscopic versus Open Vein-Graft Harvesting in Coronary-Artery Bypass Surgery [J].
Lopes, Renato D. ;
Hafley, Gail E. ;
Allen, Keith B. ;
Ferguson, T. Bruce ;
Peterson, Eric D. ;
Harrington, Robert A. ;
Mehta, Rajendra H. ;
Gibson, C. Michael ;
Mack, Michael J. ;
Kouchoukos, Nicholas T. ;
Califf, Robert M. ;
Alexander, John H. .
NEW ENGLAND JOURNAL OF MEDICINE, 2009, 361 (03) :235-244
[23]   Disruption of graft endothelium correlates with early failure after off-pump coronary artery bypass surgery [J].
Manchio, JV ;
Gu, JY ;
Romar, L ;
Brown, J ;
Gammie, J ;
Pierson, RN ;
Griffith, B ;
Poston, RS .
ANNALS OF THORACIC SURGERY, 2005, 79 (06) :1991-1998
[24]   Aortocoronary saphenous vein graft disease - Pathogenesis, predisposition, and prevention [J].
Motwani, JG ;
Topol, EJ .
CIRCULATION, 1998, 97 (09) :916-931
[25]   Impact of Endoscopic Versus Open Saphenous Vein Harvest Techniques on Outcomes After Coronary Artery Bypass Grafting [J].
Ouzounian, Maral ;
Hassan, Ansar ;
Buth, Karen J. ;
MacPherson, Celeste ;
Ali, Idris M. ;
Hirsch, Gregory M. ;
Ali, Imtiaz S. .
ANNALS OF THORACIC SURGERY, 2010, 89 (02) :403-409
[26]   Evaluation of the PAS-Port Proximal Anastomosis System in coronary artery bypass surgery (the EPIC trial) [J].
Puskas, John D. ;
Halkos, Michael E. ;
Balkhy, Husam ;
Caskey, Michael ;
Connolly, Mark ;
Crouch, John ;
Diegeler, Anno ;
Gummert, Jan ;
Harringer, Wolfgang ;
Subramanian, Valavanur ;
Sutter, Francis ;
Matschke, Klaus .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 138 (01) :125-132
[27]  
*STS, 2008, STS AD CARD SURG DAT
[28]   The coronary artery bypass conduit: I. Intraoperative endothelial injury and its implication on graft patency [J].
Thatte, HS ;
Khuri, SF .
ANNALS OF THORACIC SURGERY, 2001, 72 (06) :S2245-S2252
[29]  
TYRAS DH, 1980, J THORAC CARDIOV SUR, V80, P327
[30]   Frequency, manifestations, and correlates of impaired healing of saphenous vein harvest incisions [J].
WipkeTevis, DD ;
Stotts, NA ;
Skov, P ;
CarrieriKohlman, V .
HEART & LUNG, 1996, 25 (02) :108-116