Comparison of neointimal feature between bioabsorbable polymer everolimus eluting stent and permanent polymer everolimus eluting stent evaluated by serial angioscopy and optical coherence tomography

被引:0
|
作者
Akutsu, N. [1 ]
Takayama, T. [1 ]
Takei, N. [1 ]
Kougo, T. [1 ]
Iida, K. [1 ]
Murata, N. [1 ]
Nishida, T. [1 ]
Oshima, T. [1 ]
Haruta, H. [1 ]
Fukamachi, D. [1 ]
Hiro, T. [1 ]
Hirayama, A. [1 ]
机构
[1] Nihon Univ, Cardiol, Tokyo, Japan
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
P2821
引用
收藏
页码:577 / 578
页数:2
相关论文
共 50 条
  • [1] Comparison of in-stent responses in 8 month between durable polymer and bioabsorbable polymer everolimus-eluting stent: serial observation with angioscopy and optical coherence tomography
    Kitano, D.
    Takayama, T.
    Fukamachi, D.
    Migita, S.
    Morikawa, T.
    Kogo, T.
    Kojima, K.
    Mineki, T.
    Murata, N.
    Akutsu, N.
    Oshima, T.
    Sudo, M.
    Haruta, H.
    Hiro, T.
    Hirayama, A.
    EUROPEAN HEART JOURNAL, 2018, 39 : 528 - 528
  • [2] Comparison between a novel bioabsorbable polymer everolimus-eluting stent and a durable polymer everolimus-eluting stent
    Tsutsumi, M.
    Ito, Y.
    Hirano, K.
    Yamawaki, M.
    Araki, M.
    Kobayashi, N.
    Mori, S.
    Sakamoto, Y.
    Honda, Y.
    Tokuda, T.
    Makino, K.
    Shirai, S.
    EUROPEAN HEART JOURNAL, 2018, 39 : 135 - 135
  • [3] Comparison of neointimal coverage between biodegradable-polymer everolimus-eluting stent and durable-polymer everolimus-eluting stent using angioscopy for the patients with acute coronary syndrome
    Umemoto, T.
    Matsuda, J.
    Hatano, Y.
    Lee, T.
    Yonetsu, T.
    Sasano, T.
    EUROPEAN HEART JOURNAL, 2020, 41 : 2449 - 2449
  • [4] Comparison of Neointimal Response between Durable-Polymer Everolimus-Eluting Stent and Bioabsorbable-Polymer Everolimus-Eluting Stent for Severely Calcified Lesions Requiring Rotational Atherectomy Serial OCT Analysis
    Matsuda, Yuji
    Ashikaga, Takashi
    Sasaoka, Taro
    Hatano, Yu
    Umemoto, Tomoyuki
    Lee, Tetsumin
    Yonetsu, Taishi
    Maejima, Yasuhiro
    Sasano, Tetsuo
    INTERNATIONAL HEART JOURNAL, 2020, 61 (04) : 665 - 672
  • [5] ComparisOn of neointimal coVerage betwEen zotaRolimus-eluting stent and everolimus-eluting stent using Optical Coherence Tomography (COVER OCT)
    Kim, Jung-Sun
    Kim, Byeong-Kuk
    Jang, Ik-Kyung
    Shin, Dong-Ho
    Ko, Young-Guk
    Choi, Donghoon
    Hong, Myeong-Ki
    Cho, Yun-Kyeong
    Nam, Chang-Wook
    Hur, Seung-Ho
    Choi, Jin-Ho
    Song, Young Bin
    Hahn, Joo Yong
    Choi, Seung Hyuk
    Gwon, Hyeon Cheol
    Jang, Yangsoo
    AMERICAN HEART JOURNAL, 2012, 163 (04) : 601 - 607
  • [6] Comparison of neointimal coverage and extra-stent lumen between sirolimus and everolimus-eluting stent using optical coherence tomography
    Oda, Takamasa
    Okamura, Takayuki
    Yamada, Jutaro
    Miyagi, Naoto
    Uehara, Hiroki
    Nao, Tomoko
    Tateishi, Hiroki
    Maeda, Takao
    Nakamura, Takeshi
    Shiraishi, Kohzoh
    Nakashima, Tadamitsu
    Nishimura, Shigehiko
    Miura, Toshiro
    Matsuzaki, Masunori
    Yano, Masafumi
    HEART AND VESSELS, 2016, 31 (04) : 449 - 456
  • [7] Comparison of neointimal coverage and extra-stent lumen between sirolimus and everolimus-eluting stent using optical coherence tomography
    Takamasa Oda
    Takayuki Okamura
    Jutaro Yamada
    Naoto Miyagi
    Hiroki Uehara
    Tomoko Nao
    Hiroki Tateishi
    Takao Maeda
    Takeshi Nakamura
    Kohzoh Shiraishi
    Tadamitsu Nakashima
    Shigehiko Nishimura
    Toshiro Miura
    Masunori Matsuzaki
    Masafumi Yano
    Heart and Vessels, 2016, 31 : 449 - 456
  • [8] OUTCOMES OF EVEROLIMUS-ELUTING STENT INCOMPLETE STENT APPOSITION: A SERIAL OPTICAL COHERENCE TOMOGRAPHY ANALYSIS
    Shimamura, Kunihiro
    Kubo, Takashi
    Akasaka, Takashi
    Kozuma, Ken
    Kimura, Kazuo
    Sumiyoshi, Tetsuya
    Ino, Yasushi
    Yoshiyama, Minoru
    Sonoda, Shinjo
    Igarashi, Keiichi
    Miyazawa, Akiyoshi
    Uzui, Hiroyasu
    Sakanoue, Yuji
    Shinke, Toshiro
    Morino, Yoshihiro
    Tanabe, Kengo
    Kadota, Kazushige
    Kimura, Takeshi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1794 - A1794
  • [9] Outcomes of everolimus-eluting stent incomplete stent apposition: a serial optical coherence tomography analysis
    Shimamura, Kunihiro
    Kubo, Takashi
    Akasaka, Takashi
    Kozuma, Ken
    Kimura, Kazuo
    Kawamura, Masaki
    Sumiyoshi, Tetsuya
    Ino, Yasushi
    Yoshiyama, Minoru
    Sonoda, Shinjo
    Igarashi, Keiichi
    Miyazawa, Akiyoshi
    Uzui, Hiroyasu
    Sakanoue, Yuji
    Shinke, Toshiro
    Morino, Yoshihiro
    Tanabe, Kengo
    Kadota, Kazushige
    Kimura, Takeshi
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2015, 16 (01) : 23 - 28
  • [10] ANGIOSCOPIC NEOINTIMAL CHANGE OF EVEROLIMUS-ELUTING STENT COMPARED TO PACLITAXEL-ELUTING STENT: A SERIAL OBSERVATION OF CORONARY ANGIOSCOPY IN MULTICENTER
    Kitano, Daisuke
    Takayama, Tadateru
    Saruya, Tadahiro
    Kawano, Taro
    Kanai, Takashi
    Harasawa, Kazuo
    Hiro, Takafumi
    Tochihara, Toshihiko
    Saito, Satoshi
    Hirayama, Atsushi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1846 - E1846