Paramedian access to the epidural space: The optimum window for ultrasound imaging

被引:114
作者
Grau, T [1 ]
Leipold, RW [1 ]
Horter, J [1 ]
Conradi, R [1 ]
Martin, EO [1 ]
Motsch, J [1 ]
机构
[1] Heidelberg Univ, Dept Anaesthesiol, D-69120 Heidelberg, Germany
关键词
epidural space; ultrasound imaging; paramedian access;
D O I
10.1016/S0952-8180(01)00245-8
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Study Objective: To establish a useful ultrasonic approach to the epidural space so as to optimize pre-puncture diagnostics. Design: Prospective study. Setting: University clinic. Patients: 60 participants (19 to 34 years of age), 40 healthy volunteers (20 male, 20 female) and 20 parturients. Interventions: Ultrasound scanning of the lumbar spine was performed at the L-3-L-4 vertebral interspace. Three ultrasound planes were employed: the transverse, median, and paramedian longitudinal approaches. Measurements: We compared the width of the ultrasound-permeable area in the median and paramedian planes and assessed the visibility of the epidural space and its surrounding structures. Main Results: In the paramedian plane, the permeable window was larger (p < 0.001) than in the median approach. The visibility of the ligamentum flavum (p < 0.0001), dura mater (p < 0.0001), and cauda equina (p < 0.0001) was significantly higher Pulsation of epidural vessels could be observed more frequently (p < 0.0001) in the paramedian plane. Conclusions: The longitudinal paramedian plane provided information about the epidural space depth in excellent imaging quality. The additional information might be beneficial in epidural anesthesia and in other clinical specialties (e.g, neurosurgery, trauma care). (C) 2001 by Elsevier Science Inc.
引用
收藏
页码:213 / 217
页数:5
相关论文
共 16 条
  • [1] BLOMBERG RG, 1988, ANAESTHESIA, V43, P837
  • [2] Bonazzi M, 1995, Minerva Anestesiol, V61, P201
  • [3] Cittadini G, 1995, Radiol Med, V89, P12
  • [4] Combined spinal-epidural techniques
    Cook, TM
    [J]. ANAESTHESIA, 2000, 55 (01) : 42 - 64
  • [5] CORK RC, 1980, ANESTHESIOLOGY, V52, P513
  • [6] MEASUREMENT OF THE DEPTH TO THE EXTRADURAL SPACE USING ULTRASOUND
    CURRIE, JM
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1984, 56 (04) : 345 - 347
  • [7] DELORME S, 1998, ULTRASOUND DIAGNOSTI
  • [8] GRAU T, IN PRESS ANAESTHESIS
  • [9] THE DEPTH OF THE LUMBAR EPIDURAL SPACE FROM THE SKIN
    HARRISON, GR
    CLOWES, NWB
    [J]. ANAESTHESIA, 1985, 40 (07) : 685 - 687
  • [10] A new combined spinal-epidural apparatus: Measurement of the distance to the epidural and subarachnoid spaces
    Hoffmann, VLH
    Vercauteren, MP
    Buczkowski, W
    Vanspringel, GLJ
    [J]. ANAESTHESIA, 1997, 52 (04) : 350 - 355