Wavefront aberrometry repeatability and agreement-A comparison between Pentacam AXL Wave, iTrace and OPD-Scan III

被引:8
作者
Wan, Kelvin H. [1 ,2 ,3 ]
Liao, Xu Lin [1 ]
Yu, Marco [4 ]
Tsui, Rachel W. Y. [1 ,2 ]
Chow, Vanissa W. S. [1 ,2 ]
Chong, Kelvin K. L. [1 ]
Chan, Tommy C. Y. [1 ,5 ]
机构
[1] Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Shatin, Hong Kong, Peoples R China
[2] Hong Kong Eye Hosp, Kowloon, Hong Kong, Peoples R China
[3] C MER Dennis Lam & Partners Eye Ctr, C MER Int Eye Care Grp, Hong Kong, Peoples R China
[4] Singapore Natl Eye Ctr, Singapore Eye Res Inst, Singapore, Singapore
[5] Hong Kong Sanat & Hosp, Dept Ophthalmol, Happy Valley, Hong Kong, Peoples R China
关键词
aberration; aberrometry; wavefront; Zernike polynomials; HIGHER-ORDER ABERRATIONS; REPRODUCIBILITY; TRACEY; EYE;
D O I
10.1111/opo.13047
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction To compare intrasession agreement and repeatability of wavefront aberration measurements from three different aberrometers obtained using Hartmann-Shack, ray tracing and automated retinoscopy methods, as well as their interdevice agreement. Methods Three consecutive measurements were obtained using the Pentacam AXL Wave, the iTrace and the OPD-Scan III in 47 eyes of 47 patients. Wavefront refractions, root mean square of total aberrations (RMS total), RMS of higher-order aberrations (HOA) and second-, third- and fourth-order HOAs were exported for 4-mm pupils. Wavefront refractions were converted into vector components: M, J(0) and J(45). Intrasession agreement and repeatability were evaluated using intraclass correlation coefficients (ICCs) and repeatability coefficients (RCs); interdevice agreement was assessed using the Bland-Altman method. Results The intrasession agreement and repeatability of RMS HOA were comparable between the three devices; both the Pentacam AXL Wave and the OPD-Scan III had better intrasession agreement and repeatability for the RMS total than the iTrace (p <= 0.02). Intrasession repeatability for the majority of second- and third-order aberrations was better on the Pentacam AXL Wave than on the iTrace (p <= 0.01) and OPD-Scan III (p <= 0.04), although their agreement and repeatability in spherical aberration were comparable (p >= 0.24). Significant systematic differences and proportional bias were detected for almost all refraction power vectors and Zernike coefficients among the three devices. Conclusions In this study, all three devices provided good-to-excellent agreement for aberration measurements. Most of the individual Zernike's components were not exchangeable between different aberrometers. Their relative intrasession performance in agreement and repeatability varied significantly across different ocular aberration parameters.
引用
收藏
页码:1326 / 1337
页数:12
相关论文
共 28 条
[1]   CONTROLLING THE FALSE DISCOVERY RATE - A PRACTICAL AND POWERFUL APPROACH TO MULTIPLE TESTING [J].
BENJAMINI, Y ;
HOCHBERG, Y .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-STATISTICAL METHODOLOGY, 1995, 57 (01) :289-300
[2]   Higher order aberrations in normal eyes measured with three different aberrometers [J].
Burakgazi, Ahmet Z. ;
Tinio, Bernard ;
Bababyan, Alejandro ;
Niksarli, Kevin Kevork ;
Asbell, Penny .
JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (09) :898-903
[3]   Analysis of Four Aberrometers for Evaluating Lower and Higher Order Aberrations [J].
Cade, Fabiano ;
Cruzat, Andrea ;
Paschalis, Eleftherios I. ;
Santo, Lilian Espirito ;
Pineda, Roberto .
PLOS ONE, 2013, 8 (01)
[4]   Test-retest reliability of clinical Shack-Hartmann measurements [J].
Cheng, X ;
Himebaugh, NL ;
Kollbaum, PS ;
Thibos, LN ;
Bradley, A .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (01) :351-360
[5]   Prospective, Randomized Contralateral Eye Comparison of Wavefront-Guided Laser In Situ Keratomileusis and Small Incision Lenticule Extraction Refractive Surgeries [J].
Chiang, Bryce ;
Valerio, Gabriel S. ;
Manche, Edward E. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2022, 237 :211-220
[6]  
Chow S-C., 2017, SAMPLE SIZE CALCULAT
[7]   Serial measurements of higher-order aberrations after blinking in normal subjects [J].
Koh, Shizuka ;
Maeda, Naoyuki ;
Hirohara, Yoko ;
Mihashi, Toshifumi ;
Ninomiya, Sayuri ;
Bessho, Kenichiro ;
Watanabe, Hitoshi ;
Fujikado, Takashi ;
Tano, Yasuo .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (08) :3318-3324
[8]   Comparison of higher-order wavefront aberrations with 3 aberrometers [J].
Liang, CL ;
Juo, SHH ;
Chang, CJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (11) :2153-2156
[9]   OBJECTIVE MEASUREMENT OF WAVE ABERRATIONS OF THE HUMAN EYE WITH THE USE OF A HARTMANN-SHACK WAVE-FRONT SENSOR [J].
LIANG, JZ ;
GRIMM, B ;
GOELZ, S ;
BILLE, JF .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1994, 11 (07) :1949-1957
[10]   Recent advances in wavefront-guided LASIK [J].
Manche, Edward ;
Roe, Joshua .
CURRENT OPINION IN OPHTHALMOLOGY, 2018, 29 (04) :287-292