Clinical Assessment of Dental Implant Stability During Follow-Up: What Is Actually Measured, and Perspectives

被引:41
作者
Zanetti, Elisabetta M. [1 ]
Pascoletti, Giulia [1 ]
Cali, Michele [2 ]
Bignardi, Cristina [3 ]
Franceschini, Giordano [1 ]
机构
[1] Univ Perugia, Dipartimento Ingn, I-06125 Perugia, Italy
[2] Univ Catania, DIEEI, I-95125 Catania, Italy
[3] Politecn Torino, DIMEAS, I-10129 Turin, Italy
来源
BIOSENSORS-BASEL | 2018年 / 8卷 / 03期
关键词
implant stability; osseointegration; modal analysis; resonance frequency; ultrasound; reverse torque; functional loading; early loading; damping; RESONANCE FREQUENCY-ANALYSIS; IN-VITRO; BIOMECHANICAL STABILITY; ULTRASONIC EVALUATION; EDENTULOUS PATIENTS; OSSEOINTEGRATION; IMMEDIATE; PERIOTEST; OVERDENTURES; PARAMETERS;
D O I
10.3390/bios8030068
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The optimization of loading protocols following dental implant insertion requires setting up patient-specific protocols, customized according to the actual implant osseointegration, measured through quantitative, objective methods. Various devices for the assessment of implant stability as an indirect measure of implant osseointegration have been developed. They are analyzed here, introducing the respective physical models, outlining major advantages and critical aspects, and reporting their clinical performance. A careful discussion of underlying hypotheses is finally reported, as is a suggestion for further development of instrumentation and signal analysis.
引用
收藏
页数:18
相关论文
共 89 条
  • [1] Implant design and intraosseous stability of immediately placed implants: a human cadaver study
    Akkocaoglu, M
    Uysal, S
    Tekdemir, I
    Akca, K
    Cehreli, MC
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (02) : 202 - 209
  • [2] Effects of different loading protocols on the secondary stability and peri-implant bone density of the single implants in the posterior maxilla
    Akoglan, Mucahide
    Tatli, Ufuk
    Kurtoglu, Cem
    Salimov, Fariz
    Kurkcu, Mehmet
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (04) : 624 - 631
  • [3] Assessment of Osstell (TM) and Periotest((R)) systems in measuring dental implant stability (in vitro study)
    Al-Jetaily, Samer
    Al-Dosari, Abdullah AlFarraj
    [J]. SAUDI DENTAL JOURNAL, 2011, 23 (01) : 17 - 21
  • [4] Primary and Secondary Stability of Single Short Implants
    Alonso, Fernando R.
    Triches, Diego F.
    Mezzomo, Luis A. M.
    Teixeira, Eduardo R.
    Shinkai, Rosemary S. A.
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (06) : E548 - E551
  • [5] TOOTH ANKYLOSIS - CLINICAL, RADIOGRAPHIC AND HISTOLOGICAL ASSESSMENTS
    ANDERSSON, L
    BLOMLOF, L
    LINDSKOG, S
    FEIGLIN, B
    HAMMARSTROM, L
    [J]. INTERNATIONAL JOURNAL OF ORAL SURGERY, 1984, 13 (05): : 423 - 431
  • [6] [Anonymous], 2014, DENT IMPLANT PROSTHE
  • [7] [Anonymous], WORLD J PHARM LIFE S
  • [8] [Anonymous], DENT IMPLANT PROSTHE
  • [9] [Anonymous], IMPLANT STABILITY ME
  • [10] Aoki H, 1987, Kanagawa Shigaku, V22, P13