Numerical and Experimental Study of the Ventilation in an Operating Hydrogenerator

被引:4
作者
Torriano, F. [1 ]
Stella, S. [2 ]
Jayet, Y. [2 ]
Ardaillon, T. [2 ]
Charest-Fournier, J-P [1 ]
Hudon, C. [1 ]
Merkhouf, A. [2 ]
Guillot, E. [3 ]
机构
[1] Inst Rech Hydro Quebec, Varennes, PQ, Canada
[2] EDF DTG Diagnost Mat Elect, Grenoble, France
[3] EDF Dept THEMIS, Palaiseau, France
来源
INTERNATIONAL CONFERENCE ON NUMERICAL ANALYSIS AND APPLIED MATHEMATICS (ICNAAM-2018) | 2019年 / 2116卷
关键词
HEAT-TRANSFER; COOLING AIR; FLOW; MODEL;
D O I
10.1063/1.5114470
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
In this paper, a three-dimensional CFD simulation of the air flow in a 14.4 MVA hydrogenerator in service at EDF is performed. This machine was selected because it presents a large axial temperature gradient in the stator core that imposes some load limitations. The computational domain includes all the main components of the hydrogenerator (rotor, stator, frame and housing) except for the coolers since they would require a much higher meshing and computational effort. The numerical results show a significant axial flow maldistribution across the stator ducts with a flow blockage in the bottom duct that is most probably responsible for the overheating observed in the bottom region of the stator core. This finding has been validated through air flow measurements that were performed at the outlet of several stator ducts using a custom sensor developed at Hydro-Quebec's Research Institute. Furthermore, the computed windage losses in the hydrogenerator were compared with the measured ones and a discrepancy lower than 1% was found. Consequently, this numerical investigation has successfully proven the capability of a CFD model to reproduce the ventilation anomalies present in an operating hydrogenerator, as long as the input parameters of the model are carefully fixed. Moreover, this approach can provide engineers with useful information that could help them solve cooling issues.
引用
收藏
页数:7
相关论文
共 23 条
  • [1] Bach E, 2016, PROCEEDINGS OF THE ASME POWER CONFERENCE, 2015
  • [2] Evolution and Modern Approaches for Thermal Analysis of Electrical Machines
    Boglietti, Aldo
    Cavagnino, Andrea
    Staton, David
    Shanel, Martin
    Mueller, Markus
    Mejuto, Carlos
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (03) : 871 - 882
  • [3] CFD analysis of turbulent convective heat transfer in a hydro-generator rotor-stator system
    Dang, D. -D.
    Pham, X. -T.
    Labbe, P.
    Torriano, F.
    Morissette, J. -F.
    Hudon, C.
    [J]. APPLIED THERMAL ENGINEERING, 2018, 130 : 17 - 28
  • [4] Fan Z.N., 2008, P 11 INT C EL MACH S
  • [5] Filipan V., 1993, International Water Power & Dam Construction, V45, P44
  • [6] Gunabushanam N., 2006, Experimental and CFD Analysis of Hydrogenerator Ventilation Components
  • [7] Calculation and analysis of complex fluid flow and thermal fields in a fully air-cooled hydrogenerator
    Han Jichao
    Ge Baojun
    Tao Dajun
    Zhao Hongsen
    Xiao Fang
    Li Weili
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2017, 116 : 278 - 286
  • [8] Hartono E., 2012, TECHNICAL REPORT
  • [9] Hudon C., 2010, EUROPEAN J ELECT ENG, V13/5-6, P563
  • [10] Jordan B., 2011, HYDRO 2011 C PRAG