Tests of a full-scale ITER toroidal interferometer and polarimeter (TIP) prototype on the DIII-D tokamak (invited)

被引:22
作者
Van Zeeland, M. A. [1 ]
Carlstrom, T. N. [1 ]
Finkenthal, D. K. [2 ]
Akiyama, T. [3 ]
Boivin, R. L. [1 ]
Colio, A. [2 ]
Du, D. [1 ]
Gattuso, A. [1 ]
Glass, F. [1 ]
Muscatello, C. M. [1 ]
O'Neill, R. [1 ]
Smiley, M. [1 ]
Vasquez, J. [1 ]
Watkins, M. [1 ]
Brower, D. L. [4 ]
Chen, J. [4 ]
Ding, W. X. [4 ]
Johnson, D. [5 ]
Mauzey, P. [1 ]
Perry, M. [6 ]
Watts, C. [7 ]
Wood, R. [5 ]
机构
[1] Gen Atom Co, POB 85608, San Diego, CA 92186 USA
[2] Palomar Sci Instruments, San Marcos, CA 92069 USA
[3] Natl Inst Fus Sci, Gifu 5095292, Japan
[4] Univ Calif Los Angeles, Dept Phys & Astronamy, Los Angeles, CA 90095 USA
[5] Princeton Plasma Phys Lab, POB 451, Princeton, NJ 08543 USA
[6] Calif State Univ, San Marcos, CA 92096 USA
[7] ITER Org, F-13067 St Paul Les Durance, France
关键词
DENSITY-MEASUREMENT; SYSTEM;
D O I
10.1063/1.5037461
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A full-scale ITER toroidal interferometer and polarimeter (TIP) prototype, including an active feedback alignment system, has been installed and tested on the DIII-D tokamak. In the TIP prototype, a two-color interferometry measurement of line-integrated density is carried out at 10.59 mu m and 5.22 mu m using a CO2 and quantum cascade laser, respectively, while a separate polarimetry measurement of the plasma-induced Faraday effect is made at 10.59 mu m. The TIP prototype is equipped with a piezo tip/tilt stage active feedback alignment system that minimizes noise in the measurement and keeps the diagnostic aligned throughout DIII-D discharges. The measured phase resolution for the polarimeter and interferometer is 0.05 degrees (100 Hz bandwidth) and 1.9 degrees (1 kHz bandwidth), respectively. The corresponding line-integrated density resolution for the vibration-compensated interferometer is delta nL = 1.5 x 10(18) m(-2), and the magnetic field-weighted line-integrated density from the polarimeter is delta nBL = 1.5 x 10(19) Tm-2. Both interferometer and polarimeter measurements during DIII-D discharges compare well with the expectations based on calculations using Thomson scattering measured density profiles and magnetic equilibrium reconstructions. Additionally, larger bandwidth interferometer measurements show that the diagnostic is a sensitive monitor of core density fluctuations with demonstrated measurements of Alfven eigenmodes and tearing modes. Published by AIP Publishing.
引用
收藏
页数:9
相关论文
共 13 条
[1]   CO2 laser polarimeter for electron density profile measurement on the Large Helical Device [J].
Akiyama, T ;
Tsuji-Iio, S ;
Shimada, R ;
Nakayama, K ;
Okajima, S ;
Takahashi, M ;
Terai, K ;
Tanaka, K ;
Tokuzawa, T ;
Kawahata, K .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (05) :2695-2703
[2]   Multichannel far-infrared polarimeter-interferometer system on the MST reversed field pinch [J].
Brower, DL ;
Jiang, Y ;
Ding, WX ;
Terry, SD ;
Lanier, NE ;
Anderson, JK ;
Forest, CB ;
Holly, D .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (01) :1077-1080
[3]  
Carlstrom T.N., 1998, DIAGNOSTICS EXPT THE, V2
[4]   REAL-TIME, VIBRATION-COMPENSATED CO2 INTERFEROMETER OPERATION ON THE DIII-D TOKAMAK [J].
CARLSTROM, TN ;
AHLGREN, DR ;
CROSBIE, J .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (07) :1063-1066
[5]   Laser Faraday rotation measurement of current density fluctuations and electromagnetic torque (invited) [J].
Ding, WX ;
Brower, DL ;
Deng, BH ;
Craig, D ;
Prager, SC ;
Svidzinski, V .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10) :3387-3392
[6]   Chapter 7: Diagnostics [J].
FOM-Institute for Plasma Physics Rijnhuizen, Association EURATOM-FOM, Partner in the Trilateral Euregio Cluster, PO Box 1207, 3430 BE Nieuwegein, Netherlands ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 ;
不详 .
Nucl Fusion, 2007, 6 (S337-S384) :S337-S384
[7]   Dual CO2 laser interferometer with a wavelength combination of 10.6 and 9.27 mu m for electron density measurement on large tokamaks [J].
Kawano, Y ;
Nagashima, A ;
Hatae, T ;
Gunji, S .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (04) :1520-1528
[8]   Toroidal interferometer/polarimeter density measurement system on ITER [J].
Kondoh, T ;
Costley, AE ;
Sugie, T ;
Kawano, Y ;
Malaquias, A ;
Walker, CI .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10) :3420-3422
[9]   RECONSTRUCTION OF CURRENT PROFILE PARAMETERS AND PLASMA SHAPES IN TOKAMAKS [J].
LAO, LL ;
STJOHN, H ;
STAMBAUGH, RD ;
KELLMAN, AG ;
PFEIFFER, W .
NUCLEAR FUSION, 1985, 25 (11) :1611-1622
[10]   Tests of a two-color interferometer and polarimeter for ITER density measurements [J].
Van Zeeland, M. A. ;
Carlstrom, T. N. ;
Finkenthal, D. K. ;
Boivin, R. L. ;
Colio, A. ;
Du, D. ;
Gattuso, A. ;
Glass, F. ;
Muscatello, C. M. ;
O'Neill, R. ;
Smiley, M. ;
Vasquez, J. ;
Watkins, M. ;
Brower, D. L. ;
Chen, J. ;
Ding, W. X. ;
Johnson, D. ;
Mauzey, P. ;
Perry, M. ;
Watts, C. ;
Wood, R. .
PLASMA PHYSICS AND CONTROLLED FUSION, 2017, 59 (12)