Development of an automatic sequential injection analysis-lab on valve system exploiting molecularly imprinted polymers coupled with high performance liquid chromatography for the determination of estrogens in wastewater samples

被引:22
作者
Gonzalez, Alba [1 ]
Cerda, Victor [1 ,2 ]
机构
[1] Univ Balearic Isl, Sciware Syst SL Spin Off, C Pi 37, Illes Balears 07193, Spain
[2] Univ Balearic Isl, Fac Sci, Dept Chem, Carretera Valldemossa Km 7-5, E-07122 Palma de Mallorca, Illes Balears, Spain
关键词
Estrogens; Automation; Lab-on-valve; Microsolid phase extraction; Liquid chromatography; SOLID-PHASE EXTRACTION;
D O I
10.1016/j.talanta.2019.120564
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In recent years, the discharge of estrogens into the environmental water bodies through the effluents of sewage treatment plants is an issue of increasing concern, since they can act as endocrine-disrupting compounds. For this reason, there is a need of developing selective, sensitive and environmentally friendly methodologies for their determination. In this work, we present an automatic procedure for the clean-up, preconcentration and quantification of the estrogens most used in contraceptives (estrone, E1; 17 beta-estradiol, E2; estriol, E3; and 17 alpha-ethynylestradiol, EE2), which are also catalogued as Contaminants of Emergent Concern by the Environmental Protection Agency of the United States (US EPA). A sequential injection analysis-lab on valve system (SIA-LOV) using a molecularly imprinted polymer (MT) as a sorbent has been developed to perform the selective microsolid phase extraction (mu SPE) of the analytes in a fully automated way. Several parameters affecting the extraction have been optimized following multivariate approaches. Besides, the preconcentration system has been coupled to an HPLC for the estrogens quantification. Low limits of detection (LODs) and limits of quantification (LOQs) have been achieved; hence the studied estrogens can be quantified in a wide range of concentrations, i.e. 9.2-100 mu g L-1 of E3, 8.7-100 mu g L-1 of E2, 6.5-100 mu g L-1 of EE2 and 7.9-100 mu g L(-1 )of E1. Besides, satisfactory precision has been obtained, with relative standard deviations (RSDs) lower than 4.9% and 12.1% for intra and inter-day precision, respectively. Finally, the method has been successfully applied to real wastewater samples.
引用
收藏
页数:6
相关论文
共 22 条
  • [1] [Anonymous], 1996, EUR WORKSH IMP END D
  • [2] Lab on valve-multisyringe flow injection system (LOV-MSFIA) for fully automated uranium determination in environmental samples
    Avivar, Jessica
    Ferrer, Laura
    Casas, Montserrat
    Cercia, Victor
    [J]. TALANTA, 2011, 84 (05) : 1221 - 1227
  • [3] Determination of the steroid hormone levels in water samples by dispersive liquid-liquid microextraction with solidification of a floating organic drop followed by high-performance liquid chromatography
    Chang, Chu-Chi
    Huang, Shang-Da
    [J]. ANALYTICA CHIMICA ACTA, 2010, 662 (01) : 39 - 43
  • [4] Fully-automated on-line solid phase extraction coupled to high-performance liquid chromatography-tandem mass spectrometric analysis at sub-ng/L levels of selected estrogens in surface water and wastewater
    Ciofi, L.
    Fibbi, D.
    Chiuminatto, U.
    Coppini, E.
    Checchini, L.
    Del Bubba, M.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2013, 1283 : 53 - 61
  • [5] Fate of natural estrogen conjugates in municipal sewage transport and treatment facilities
    D'Ascenzo, G
    Di Corcia, A
    Gentili, A
    Mancini, R
    Mastropasqua, R
    Nazzari, M
    Samperi, R
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2003, 302 (1-3) : 199 - 209
  • [6] DERRINGER G, 1980, J QUAL TECHNOL, V12, P214, DOI 10.1080/00224065.1980.11980968
  • [7] Environmental Protection Agency (EPA), AN METH CONT EM PHAR
  • [8] Molecularly imprinted solid-phase extraction combined with high performance liquid chromatography for analysis of phenolic compounds from environmental water samples
    Feng, Qin-Zhong
    Zhao, Li-Xia
    Yan, Wei
    Lin, Jin-Ming
    Zheng, Zhi-Xia
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2009, 167 (1-3) : 282 - 288
  • [9] The 12 principles of green analytical chemistry and the SIGNIFICANCE mnemonic of green analytical practices
    Galuszka, Agnieszka
    Migaszewski, Zdzislaw
    Namiesnik, Jacek
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2013, 50 : 78 - 84
  • [10] Molecularly imprinted SPE coupled with HPLC for the selective separation and enrichment of alkyl imidazolium ionic liquids in environmental water samples
    Gao Xia
    Fan Jing
    Zhu Guifen
    Wang Xiaolong
    Wang Jianji
    [J]. JOURNAL OF SEPARATION SCIENCE, 2013, 36 (19) : 3277 - 3284