Study of the backside signal of micro-strip gas counters on electronic conducting glass

被引:0
|
作者
Cicognani, G [1 ]
Feltin, D [1 ]
Guerard, B [1 ]
Oed, A [1 ]
机构
[1] Inst Max Von Laue Paul Langevin, F-38042 Grenoble, France
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Microstrip gas counters (MSGC) on electronic conducting glass such as Schott S8900 have a very stable long time behaviour. However, this glass is available in only relatively thick plates. A thick substrate limits the performances of two-dimensional detectors by attenuating the signal of the backside electrode which carries the second position coordinate. In this paper we demonstrate that by using a structure with "open cathodes", where the central area of each cathode is non metallized it is possible to reduce the screening effect by decreasing the backside voltage potential with respect to the cathode voltage potential. This configuration results in a significant increase of the backside signal, whose amplitude becomes even equal to that of the anode signal when the cathodes are not connected to an external potential. As the cathode strips do not contribute to the amplification process in this mode, this leads naturally to a structure where the cathodes are removed entirely. Besides the improvement of the backside signal, another advantage of this new detector design is the very high gas amplification factor that one can achieve. However, as the ions are discharged by a current through the substrate, the voltage drop caused by this current leads to a counting rate dependance of the gas amplification factor.
引用
收藏
页码:296 / 298
页数:3
相关论文
共 50 条
  • [31] Performance of a micro-strip gas chamber in solution X-ray scattering
    Toyokawa, H
    Fujisawa, T
    Inoko, Y
    Nagayoshi, T
    Nishi, Y
    Nishikawa, Y
    Ochi, A
    Suzuki, M
    Tanimori, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 1144 - 1147
  • [32] Large scale test of wedge shaped micro strip gas counters
    Ackermann, M
    Atz, S
    Aulchenko, V
    Bachmann, S
    Baiboussinov, B
    Barthe, S
    Beaumont, W
    Beckers, T
    Beissel, F
    Benhammou, Y
    Bergdolt, AM
    Bernier, K
    Blüm, P
    Bondar, A
    Bouhali, O
    Boulogne, I
    Bozzo, M
    Brom, JM
    Camps, C
    Chorowicz, V
    Coffin, J
    Commichau, V
    Contardo, D
    Croix, J
    De Troy, J
    Drouhin, F
    Eberlé, H
    Flügge, G
    Fontaine, JC
    Geist, W
    Goerlach, U
    Gundlfinger, K
    Hangarter, K
    Haroutunian, R
    Helleboid, JM
    Henkes, T
    Hoffer, M
    Hoffman, C
    Huss, D
    Ischebeck, R
    Jeanneau, F
    Juillot, P
    Junghans, S
    Kapp, MR
    Kärcher, K
    Knoblauch, D
    Kräber, M
    Krauth, M
    Kremp, J
    Lounis, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (03): : 313 - 325
  • [33] ON SOME FACTORS AFFECTING DISCHARGE CONDITIONS IN MICRO-STRIP GAS-CHAMBERS
    BOUCLIER, R
    CAPEANS, M
    GARABATOS, C
    MANZIN, G
    MILLION, G
    ROPELEWSKI, L
    SAULI, F
    TEMMEL, T
    SHEKHTMAN, L
    NAGASLAEV, V
    PESTOV, Y
    KULESHOV, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 365 (01): : 65 - 69
  • [34] STUDY OF SOME FACTORS INFLUENCING PERFORMANCE OF GASEOUS MICRO-STRIP DETECTORS
    MCMAHON, T
    WILSON, J
    JONES, T
    DUERDOTH, I
    LUMB, N
    BAINES, J
    BOTTERILL, D
    EDGECOCK, R
    ENGLISH, R
    PAYNE, B
    BIGNALL, PB
    CRONE, GJ
    ESTEN, MJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3): : 293 - 296
  • [35] HIGH-RATE OPERATION AND LIFETIME STUDIES WITH MICRO-STRIP GAS-CHAMBERS
    BOHM, J
    BOUCLIER, R
    CAPEANS, M
    GARABATOS, C
    MANZIN, G
    MILLION, G
    SAULI, F
    TEMMEL, T
    SHEKHTMAN, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 360 (1-2): : 34 - 41
  • [36] Development of micro-strip gas detector system with individual readouts for neutron scattering experiments
    Tanaka, H.
    Nakamura, T.
    Yamagishi, H.
    Soyama, K.
    Aizawa, K.
    Ochi, A.
    Tanimori, T.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 612 - 615
  • [37] A MICRO-STRIP GAS COUNTER TEST WITH THE RD20 FRONT-END
    CLERGEAU, JF
    CONTARDO, D
    HAROUTUNIAN, R
    SMADJA, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 355 (2-3): : 359 - 365
  • [38] Tests and characterization of a mixed-signal read out ASIC for silicon micro-strip detectors
    Barbanera, Mattia
    Silvestre, Gianluigi
    Ambrosi, Giovanni
    Cossio, Fabio
    Rolo, Manuel Dionisio Da Rocha
    Duranti, Matteo
    Giampaolo, Raffaele Aaron
    Movileanu-Ionica, Maria
    Placidi, Pisana
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1069
  • [39] Development of the specialized integrated circuit for signal readout from micro-strip structures of a coordinate detectors
    Aulchenko, V.
    Shekhtman, L.
    Zhulanov, V.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [40] Properties of a Moscow glass micro strip gas chamber
    Gerndt, EKE
    Knapp, BA
    Shipsey, IPJ
    Geltenbort, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 388 (1-2): : 42 - 54