CRISPR-Cas12a-Powered Dual-Mode Biosensor for Ultrasensitive and Cross-validating Detection of Pathogenic Bacteria

被引:132
|
作者
Ma, Long [1 ]
Peng, Lei [1 ]
Yin, Lijuan [1 ]
Liu, Guozhen [2 ,3 ]
Man, Shuli [1 ]
机构
[1] Tianjin Univ Sci & Technol, Coll Biotechnol,China Int Sci & Technol Cooperat, State Key Lab Food Nutr & Safety,Natl & Local Uni, Minist Educ,Key Lab Ind Microbiol,Tianjin Key Lab, Tianjin 300457, Peoples R China
[2] Univ New South Wales, Grad Sch Biomed Engn, Sydney, NSW 2052, Australia
[3] Chinese Univ Hong Kong, Sch Life & Hlth Sci, Shenzhen 518172, Peoples R China
基金
中国国家自然科学基金;
关键词
CRISPR-Cas12a; trans-cleavage; colorimetric and photothermal detection; pathogenic bacteria detection; dual-mode detection; cross-validating detection; AMPLIFICATION;
D O I
10.1021/acssensors.1c00686
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Pathogenic bacteria infection severely threatens human health and causes substantial medical and financial concern. Rapid, sensitive, specific, and reliable detection of pathogenic bacteria is crucial. In the current study, a CRISPR-Cas12a-powered dual-mode biosensor was developed for ultrasensitive and cross-validating detection of pathogenic bacteria. Simply, the amplicons of Salmonella (used as a model)-specific invA sequence triggered CRISPR-Cas12a-based indiscriminate degradation of single-stranded DNAs that were supposed to link two gold nanoparticle (AuNP) probe pairs, inducing an aggregation-to-dispersion change. This generated observable color changes that became even more apparent after centrifugation. The color changes can be discerned by naked eyes and recorded using a portable colorimeter. Meanwhile, the photothermal effect of CRISPR-Cas12-powered AuNPs was explored for the first time through 808 nm near-infrared irradiation such that quantitative measurement can be carried out by recording temperatures using a thermal camera. For both modes, a limit of detection of 1 CFU/mL and a dynamic range of detection from 10(0) to 10(8) CFU/mL were obtained, which were comparable with or better than previously reported methods. Our proposed biosensor demonstrated satisfactory selectivity for Salmonella against other interfering cells. Furthermore, this biosensor proved to be capable of Salmonella detection in food samples. Regarding the real applications, the result from each mode can be used for cross-validation. Only the case having doubly confirmed positive or negative results can be assured, which rendered a more dependable biosensing conclusion. This technology not only expands the reach of the CRISPR-Cas system in biosensing but also provides a general method for bacteria sensing with desirable sensitivity, specificity, and cross-validating capacity.
引用
收藏
页码:2920 / 2927
页数:8
相关论文
共 50 条
  • [21] A CRISPR/Cas12a-based colorimetric AuNPs biosensor for naked-eye detection of pathogenic bacteria in clinical samples
    Zheng, Laibao
    Zheng, Chaochuan
    Wang, Weiwei
    Huang, Fuyuan
    Jiang, Yelin
    Lu, Jiahai
    Lou, Yongliang
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2025, 250
  • [22] CRISPR/Cas12a and immuno-RCA based electrochemical biosensor for detecting pathogenic bacteria
    Chen, Zhibao
    Ma, Li
    Bu, Shengjun
    Zhang, Wenguang
    Chen, Jinjun
    Li, Zhongyi
    Hao, Zhuo
    Wan, Jiayu
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 901
  • [23] Electrochemical biosensor for detecting pathogenic bacteria based on a hybridization chain reaction and CRISPR-Cas12a
    Xiu Liu
    Shengjun Bu
    Jingqi Feng
    Hongguo Wei
    Ze Wang
    Xue Li
    Hongyu Zhou
    Xiuxia He
    Jiayu Wan
    Analytical and Bioanalytical Chemistry, 2022, 414 : 1073 - 1080
  • [24] Electrochemical biosensor for detecting pathogenic bacteria based on a hybridization chain reaction and CRISPR-Cas12a
    Liu, Xiu
    Bu, Shengjun
    Feng, Jingqi
    Wei, Hongguo
    Wang, Ze
    Li, Xue
    Zhou, Hongyu
    He, Xiuxia
    Wan, Jiayu
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (02) : 1073 - 1080
  • [25] Smartphone-assisted self-powered dual-mode biosensor designed on binary 3D DNA Walkers mediated CRISPR/Cas12a system
    Shi, Jinyue
    Li, Peiyuan
    Huang, Yumei
    Wu, YeYu
    Wu, Jiawen
    Huang, Ke-Jing
    Tan, Xuecai
    Ya, Yu
    CHEMICAL ENGINEERING JOURNAL, 2024, 483
  • [26] CRISPR/Cas12a-drived electrochemiluminescence and fluorescence dual-mode magnetic biosensor for sensitive detection of Pseudomonas aeruginosa based on iridium(III) complex as luminophore
    Xu, Yaoyao
    Ma, Jingjing
    Dai, Chenji
    Mao, Ziwang
    Zhou, Yuyang
    BIOSENSORS & BIOELECTRONICS, 2024, 264
  • [27] A MXene-Au nanosheets-based fluorescent-SERS dual-mode biosensor integrated with CRISPR/Cas12a system for endotoxin detection
    Wu, Honglian
    Zhang, Ruolin
    Lai, Huang
    Lai, Luogen
    Liu, Yi
    Fan, Yadi
    Zhang, Yu
    Shi, Jingyu
    Yang, Mo
    SENSORS AND ACTUATORS B-CHEMICAL, 2025, 427
  • [28] CRISPR-Cas12a Coupled with Universal Dual-mode Fluorescent Nanoparticles Platform for HPV Nucleic Acid Detection
    Li Xu
    Sitong Liu
    Zhaohe Huang
    Xiaojing Pei
    Shujing Li
    Yifan He
    Yigang Tong
    Guoqi Liu
    Journal of Analysis and Testing, 2025, 9 (01) : 153 - 159
  • [29] CRISPR-Cas12a Coupled with Universal Dual-mode Fluorescent Nanoparticles Platform for HPV Nucleic Acid Detection
    Xu, Li
    Liu, Sitong
    Huang, Zhaohe
    Pei, Xiaojing
    Li, Shujing
    He, Yifan
    Tong, Yigang
    Liu, Guoqi
    JOURNAL OF ANALYSIS AND TESTING, 2025, 9 (01) : 153 - 159
  • [30] Dual-mode DNA walker-based optical fiber biosensor for ultrasensitive detection of microRNAs
    Zhao, Siqi
    Jia, Yaxue
    Wang, Anping
    Yang, Jinlan
    Yang, Li
    BIOSENSORS & BIOELECTRONICS, 2023, 239