Direct and quantitative analysis of underivatized acylcarnitines in serum and whole blood using paper spray mass spectrometry

被引:78
作者
Yang, Qian [1 ]
Manicke, Nicholas E. [2 ]
Wang, He [1 ]
Petucci, Christopher [3 ]
Cooks, R. Graham [2 ,4 ]
Ouyang, Zheng [1 ,4 ]
机构
[1] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
[2] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
[3] Sanford Burnham Med Res Inst, Metabol Core, Orlando, FL 32827 USA
[4] Purdue Univ, Ctr Analyt Instrumentat Dev, W Lafayette, IN 47907 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
Paper spray; Ambient ionization; Mass spectrometry; Acylcarnitines; Newborn screening; FAST-ATOM-BOMBARDMENT; INBORN-ERRORS; ELECTROSPRAY-IONIZATION; LIQUID-CHROMATOGRAPHY; ATMOSPHERIC-PRESSURE; THERAPEUTIC DRUGS; IN-VIVO; DIAGNOSIS; METABOLISM; PLASMA;
D O I
10.1007/s00216-012-6211-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple protocol for rapid quantitation of acylcarnitines in serum and whole blood has been developed using paper spray mass spectrometry. Dried serum and whole blood containing a mixture of ten acylcarnitines at various concentrations were analyzed as spots from paper directly without any sample pretreatment, separation, or derivatization. The composition of the spray solvent was found to be a critical factor: for serum samples, spray solvent of methanol/water/formic acid (80:20:0.1) gave the best signal intensity while for blood samples which contain more matrix components, acetonitrile/water (90:10) was a much more suitable spray solvent. For the paper type and size used, 0.5 mu L of sample provided an optimal signal for both serum and whole blood samples. For quantitative profiling, the limits of quantitation obtained from both serum and blood were much lower than the clinically validated cutoff values for diagnosis of fatty acid oxidation disorders in newborn screening. Linearity (R (2) > 0.95) and reproducibility (RSD similar to 10 %) were achieved in the concentration ranges from 100 nM to 5 mu M for the C2 acylcarnitine, and for other acylcarnitines, these values were from 10 to 500 nM. Acylcarnitine profiles offer an effective demonstration of the fact that paper spray mass spectrometry is an appropriate, simple, rapid method with high sensitivity and high reproducibility applicable to newborn screening tests.
引用
收藏
页码:1389 / 1397
页数:9
相关论文
共 53 条
  • [21] Assessment of paper spray ionization for quantitation of pharmaceuticals in blood spots
    Manicke, Nicholas E.
    Yang, Qian
    Wang, He
    Oradu, Sheran
    Ouyang, Zheng
    Cooks, R. Graham
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2011, 300 (2-3) : 123 - 129
  • [22] Quantitative Analysis of Therapeutic Drugs in Dried Blood Spot Samples by Paper Spray Mass Spectrometry: An Avenue to Therapeutic Drug Monitoring
    Manicke, Nicholas Edward
    Abu-Rabie, Paul
    Spooner, Neil
    Ouyang, Zheng
    Cooks, R. Graham
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2011, 22 (09) : 1501 - 1507
  • [23] Clinical validation of cutoff target ranges in newborn screening of metabolic disorders by tandem mass spectrometry: A worldwide collaborative project
    McHugh, David M. S.
    Cameron, Cynthia A.
    Abdenur, Jose E.
    Abdulrahman, Mahera
    Adair, Ona
    Al Nuaimi, Shahira Ahmed
    Ahlman, Henrik
    Allen, Jennifer J.
    Antonozzi, Italo
    Archer, Shaina
    Au, Sylvia
    Auray-Blais, Christiane
    Baker, Mei
    Bamforth, Fiona
    Beckmann, Kinga
    Pino, Gessi Bentz
    Berberich, Stanton L.
    Binard, Robert
    Boemer, Francois
    Bonham, Jim
    Breen, Nancy N.
    Bryant, Sandra C.
    Caggana, Michele
    Caldwell, S. Graham
    Camilot, Marta
    Campbell, Carlene
    Carducci, Claudia
    Cariappa, Rohit
    Carlisle, Clover
    Caruso, Ubaldo
    Cassanello, Michela
    Miren Castilla, Ane
    Castineiras Ramos, Daisy E.
    Chakraborty, Pranesh
    Chandrasekar, Ram
    Ramos, Alfredo Chardon
    Cheillan, David
    Chien, Yin-Hsiu
    Childs, Thomas A.
    Chrastina, Petr
    Sica, Yuri Cleverthon
    Cocho de Juan, Jose Angel
    Elena Colandre, Maria
    Cornejo Espinoza, Veronica
    Corso, Gaetano
    Currier, Robert
    Cyr, Denis
    Czuczy, Noemi
    D'Apolito, Oceania
    Davis, Tim
    [J]. GENETICS IN MEDICINE, 2011, 13 (03) : 230 - 254
  • [24] APPLICATION OF HIGH-RESOLUTION FAST ATOM BOMBARDMENT AND CONSTANT B-E RATIO LINKED SCANNING TO THE IDENTIFICATION AND ANALYSIS OF ACYLCARNITINES IN METABOLIC DISEASE
    MILLINGTON, DS
    ROE, CR
    MALTBY, DA
    [J]. BIOMEDICAL MASS SPECTROMETRY, 1984, 11 (05): : 236 - 241
  • [25] THE ANALYSIS OF DIAGNOSTIC MARKERS OF GENETIC-DISORDERS IN HUMAN BLOOD AND URINE USING TANDEM MASS-SPECTROMETRY WITH LIQUID SECONDARY ION MASS-SPECTROMETRY
    MILLINGTON, DS
    KODO, N
    TERADA, N
    ROE, D
    CHACE, DH
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1991, 111 : 211 - 228
  • [26] APPLICATION OF FAST ATOM BOMBARDMENT WITH TANDEM MASS-SPECTROMETRY AND LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY TO THE ANALYSIS OF ACYLCARNITINES IN HUMAN-URINE, BLOOD, AND TISSUE
    MILLINGTON, DS
    NORWOOD, DL
    KODO, N
    ROE, CR
    INOUE, F
    [J]. ANALYTICAL BIOCHEMISTRY, 1989, 180 (02) : 331 - 339
  • [27] Nada MA, 1996, PRENATAL DIAG, V16, P117, DOI 10.1002/(SICI)1097-0223(199602)16:2<117::AID-PD820>3.0.CO
  • [28] 2-Z
  • [29] Laser ablation electrospray ionization for atmospheric pressure, in vivo, and imaging mass spectrometry
    Nemes, Peter
    Vertes, Akos
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (21) : 8098 - 8106
  • [30] Ambient mass spectrometry for in vivo local analysis and in situ molecular tissue imaging
    Nemes, Peter
    Vertes, Akos
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2012, 34 : 22 - 34