Direct and quantitative analysis of underivatized acylcarnitines in serum and whole blood using paper spray mass spectrometry

被引:78
作者
Yang, Qian [1 ]
Manicke, Nicholas E. [2 ]
Wang, He [1 ]
Petucci, Christopher [3 ]
Cooks, R. Graham [2 ,4 ]
Ouyang, Zheng [1 ,4 ]
机构
[1] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
[2] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
[3] Sanford Burnham Med Res Inst, Metabol Core, Orlando, FL 32827 USA
[4] Purdue Univ, Ctr Analyt Instrumentat Dev, W Lafayette, IN 47907 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
Paper spray; Ambient ionization; Mass spectrometry; Acylcarnitines; Newborn screening; FAST-ATOM-BOMBARDMENT; INBORN-ERRORS; ELECTROSPRAY-IONIZATION; LIQUID-CHROMATOGRAPHY; ATMOSPHERIC-PRESSURE; THERAPEUTIC DRUGS; IN-VIVO; DIAGNOSIS; METABOLISM; PLASMA;
D O I
10.1007/s00216-012-6211-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple protocol for rapid quantitation of acylcarnitines in serum and whole blood has been developed using paper spray mass spectrometry. Dried serum and whole blood containing a mixture of ten acylcarnitines at various concentrations were analyzed as spots from paper directly without any sample pretreatment, separation, or derivatization. The composition of the spray solvent was found to be a critical factor: for serum samples, spray solvent of methanol/water/formic acid (80:20:0.1) gave the best signal intensity while for blood samples which contain more matrix components, acetonitrile/water (90:10) was a much more suitable spray solvent. For the paper type and size used, 0.5 mu L of sample provided an optimal signal for both serum and whole blood samples. For quantitative profiling, the limits of quantitation obtained from both serum and blood were much lower than the clinically validated cutoff values for diagnosis of fatty acid oxidation disorders in newborn screening. Linearity (R (2) > 0.95) and reproducibility (RSD similar to 10 %) were achieved in the concentration ranges from 100 nM to 5 mu M for the C2 acylcarnitine, and for other acylcarnitines, these values were from 10 to 500 nM. Acylcarnitine profiles offer an effective demonstration of the fact that paper spray mass spectrometry is an appropriate, simple, rapid method with high sensitivity and high reproducibility applicable to newborn screening tests.
引用
收藏
页码:1389 / 1397
页数:9
相关论文
共 53 条
  • [1] ISOLATION AND IDENTIFICATION OF ALIPHATIC SHORT-CHAIN ACYLCARNITINES FROM BEEF-HEART - POSSIBLE ROLE FOR CARNITINE IN BRANCHED-CHAIN AMINO-ACID METABOLISM
    BIEBER, LL
    CHOI, YR
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1977, 74 (07) : 2795 - 2798
  • [2] Direct analysis by electrospray ionization and matrix-assisted laser desorption ionization mass spectrometry of standard and urinary acylcarnitines - Comparison with fast atom bombardment and gas chromatography chemical ionization mass spectrometry
    Briand, G
    Fontaine, M
    Schubert, R
    Ricart, G
    Degand, P
    Vamecq, J
    [J]. JOURNAL OF MASS SPECTROMETRY, 1995, 30 (12): : 1731 - 1741
  • [3] Mass spectrometry in the clinical laboratory
    Chace, DH
    [J]. CHEMICAL REVIEWS, 2001, 101 (02) : 445 - 477
  • [4] Chace DH, 2001, CLIN CHEM, V47, P1166
  • [5] Chace DH, 1997, CLIN CHEM, V43, P436
  • [6] What Can We Learn from Ambient Ionization Techniques?
    Chen, Huanwen
    Gamez, Gerardo
    Zenobi, Renato
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (11) : 1947 - 1963
  • [7] Versatile new ion source for the analysis of materials in open air under ambient conditions
    Cody, RB
    Laramée, JA
    Durst, HD
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (08) : 2297 - 2302
  • [8] New ionization methods and miniature mass spectrometers for biomedicine: DESI imaging for cancer diagnostics and paper spray ionization for therapeutic drug monitoring
    Cooks, R. Graham
    Manicke, Nicholas E.
    Dill, Allison L.
    Ifa, Demian R.
    Eberlin, Livia S.
    Costa, Anthony B.
    Wang, He
    Huang, Guangming
    Zheng Ouyang
    [J]. FARADAY DISCUSSIONS, 2011, 149 : 247 - 267
  • [9] Ambient mass spectrometry
    Cooks, RG
    Ouyang, Z
    Takats, Z
    Wiseman, JM
    [J]. SCIENCE, 2006, 311 (5767) : 1566 - 1570
  • [10] ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES
    FENN, JB
    MANN, M
    MENG, CK
    WONG, SF
    WHITEHOUSE, CM
    [J]. SCIENCE, 1989, 246 (4926) : 64 - 71