Purpose To assess the short-term effects of caffeine intake on the biomechanical properties of the cornea, as well as its possible association with the intraocular pressure (IOP), as measured by corneal visualization Scheimpflug technology (CorVis ST) in healthy subjects. Methods Twenty-two low caffeine consumers ingested either a caffeine (4 mg/Kg) or placebo capsule in two separate sessions. IOP and corneal biomechanics parameters, including time, velocity, length, and deformation amplitude at the first applanation (A1T, A1V, A1L, and A1D, respectively); time, velocity, length, and deformation amplitude at the second applanation (A2T, A2V, A2L, and A2D, respectively); time at the highest concavity (HCT), radius curvature at the highest concavity (HCR), deformation amplitude at the highest concavity (HCDA), and peak distance (PD), were measured with the Corvis ST before and after 30 min, 60 min, and 90 min of caffeine/placebo intake. Results Caffeine intake reduced the corneal deformability, inducing significant changes in A1T, A2V, A2T, HCDA, HCT, and PD (allpvalues < 0.05). Non-corrected and biomechanically corrected IOP values were higher after caffeine intake (p = 0.001 and 0.033, respectively). Also, the changes in IOP after caffeine intake were positively associated with A1T (r = 0.790 to 0.962), and negatively associated with A2T (r = - 0.230 to - 0.722) and PD (r = - 0.506 to - 0.644). Conclusions Caffeine intake reduces the corneal deformability, with these changes being partially associated with the IOP rise. These findings evidence that exogenous factors such as caffeine intake should be taken into consideration when making clinical decisions that are based on the biomechanical properties of the cornea.
引用
收藏
页码:2449 / 2458
页数:10
相关论文
共 53 条
[1]   Measurement of Choroidal Thickness Following Caffeine Intake in Healthy Subjects [J].
Altinkaynak, Hasan ;
Ceylan, Erdinc ;
Kartal, Baki ;
Keles, Sadullah ;
Ekinci, Metin ;
Olcaysu, Osman Okan .
CURRENT EYE RESEARCH, 2016, 41 (05) :708-714
[2]   Consideration of corneal biomechanics in the diagnosis and management of keratoconus: is it important? [J].
Bao, FangJun ;
Geraghty, Brendan ;
Wang, QinMei ;
Elsheikh, Ahmed .
EYE AND VISION, 2016, 3
[3]   Effect of Single Administration of Coffee on Pupil Size and Ocular Wavefront Aberration Measurements in Healthy Subjects [J].
Bardak, Handan ;
Gunay, Murat ;
Mumcu, Ugur ;
Bardak, Yavuz .
BIOMED RESEARCH INTERNATIONAL, 2016, 2016
[4]   Caffeine consumption [J].
Barone, JJ ;
Roberts, HR .
FOOD AND CHEMICAL TOXICOLOGY, 1996, 34 (01) :119-129
[5]   Corneal structure and biomechanics: impact on the diagnosis and management of glaucoma [J].
Brown, Kimberly E. ;
Congdon, Nathan G. .
CURRENT OPINION IN OPHTHALMOLOGY, 2006, 17 (04) :338-343
[6]   Relationship among Corneal Biomechanics, Refractive Error, and Axial Length [J].
Bueno-Gimeno, Inmaculada ;
Espana-Gregori, Enrique ;
Gene-Sampedro, Andres ;
Lanzagorta-Aresti, Aitor ;
Pinero-Llorens, David P. .
OPTOMETRY AND VISION SCIENCE, 2014, 91 (05) :507-513
[7]  
EDMUND C, 1988, ACTA OPHTHALMOL, V66, P134
[8]   Biomechanical diagnostics of the cornea [J].
Esporcatte, Louise Pellegrino Gomes ;
Salomao, Marcella Q. ;
Lopes, Bernardo T. ;
Vinciguerra, Paolo ;
Vinciguerra, Riccardo ;
Roberts, Cynthia ;
Elsheikh, Ahmed ;
Dawson, Daniel G. ;
Ambrosio, Renato, Jr. .
EYE AND VISION, 2020, 7 (01)
[9]   G*Power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences [J].
Faul, Franz ;
Erdfelder, Edgar ;
Lang, Albert-Georg ;
Buchner, Axel .
BEHAVIOR RESEARCH METHODS, 2007, 39 (02) :175-191
[10]  
Gordon MO, 2002, ARCH OPHTHALMOL-CHIC, V120, P714