Influence of the type of titration and of data treatment methods on metal complexing parameters determination of single and multi-ligand systems measured by stripping voltammetry

被引:44
作者
Garnier, C
Pizeta, I
Mounier, S
Benaïm, JY
Branica, M
机构
[1] Univ Toulon & Var, RCMO PROTEE, F-83957 La Garde, France
[2] Rudjer Boskovic Inst, Ctr Marine & Environm Res, Zagreb 10002, Croatia
关键词
voltammetry; metal complexing parameters; data treatment; titration; PROSECE;
D O I
10.1016/j.aca.2003.10.066
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A set of simulated experiments was analysed in order to compare the influence of the titration type and of data treatment methods on the accuracy of metal complexing parameters determination for one- and two-ligand systems. The simulated data corresponded to those obtained by anodic stripping voltammetry and were chosen to represent experiments in linear, logarithmic and decade titration modes. The values of preset complexing parameters for one- and two-ligand systems were chosen to fit into the expected experimental range. Random noise was added to the data prior to the treatment. Five different data treatments were applied: Chau-Buffle, Ruzic-van den Berg and Scatchard linearisations, and non-linear fitting and PROSECE optimisations. The investigation has shown that even in the case of a one-ligand system, logarithmic and decade titrations are much better compared to the linear ones. Linearisation methods are in many cases inferior to those using optimisation algorithms. Random noise has a significant influence on the results of linearisation methods as well. For linearisation methods, in the case of a one-ligand system, high correlation has been found for the confidence interval of the calculated parameters and the difference between the preset and the calculated values. This correlation is proposed to be used as an estimation for the results quality in real experiments. PROSECE is by far superior to other methods in most of the cases due to its flexible and powerful mathematical background. It is highly recommended as a tool for data treatment. Construction of "contour-graphs" enables error prediction of the calculated complexing parameters. PROSECE is proposed as an orientation and valorisation tool in real samples analyses. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:263 / 275
页数:13
相关论文
共 41 条
[1]   Complexation of Cd(II) and Pb(II) with humic acids studied by anodic stripping voltammetry using differential equilibrium functions and discrete site models [J].
Abate, G ;
Masini, JC .
ORGANIC GEOCHEMISTRY, 2002, 33 (10) :1171-1182
[2]   Intercomparison of voltammetric techniques to determine the chemical speciation of dissolved copper in a coastal seawater sample [J].
Bruland, KW ;
Rue, EL ;
Donat, JR ;
Skrabal, SA ;
Moffett, JW .
ANALYTICA CHIMICA ACTA, 2000, 405 (1-2) :99-113
[3]  
BUFFLE J, 1981, J ELECTROANAL CHEM, V125, P273, DOI 10.1016/0368-1874(81)87167-5
[4]  
BUFFLE J, 1988, ANAL CHEM
[5]  
BUFFLE J, 1984, COMPLEXATION TRACE M
[7]   DETERMINATION OF LABILE AND STRONGLY BOUND METALS IN LAKE WATER [J].
CHAU, YK ;
LUMSHUEC.K .
WATER RESEARCH, 1974, 8 (06) :383-388
[8]   METAL HUMATE INTERACTIONS .1. DISCRETE LIGAND AND CONTINUOUS DISTRIBUTION MODELS [J].
DZOMBAK, DA ;
FISH, W ;
MOREL, FMM .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1986, 20 (07) :669-675
[9]   METAL HUMATE INTERACTIONS .2. APPLICATION AND COMPARISON OF MODELS [J].
FISH, W ;
DZOMBAK, DA ;
MOREL, FMM .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1986, 20 (07) :676-683
[10]  
GARNIER, UNPUB