Use of Relative vs Fixed Offset Distance to Define Region of Interest at the Distal Radius and Tibia in High-Resolution Peripheral Quantitative Computed Tomography

被引:30
作者
Shanbhogue, Vikram V. [1 ,2 ]
Hansen, Stinus [1 ,2 ]
Halekoh, Ulrich [3 ]
Brixen, Kim [1 ,2 ]
机构
[1] Odense Univ Hosp, Dept Endocrinol, DK-5000 Odense, Denmark
[2] Univ South Denmark, Inst Clin Res, Odense, Denmark
[3] Univ South Denmark, Dept Epidemiol Biostat & Biodemog, Odense, Denmark
关键词
HR-pQCT; region of interest; relative measurement method; standard measurement protocol; BONE MICROARCHITECTURE; HR-PQCT; POSTMENOPAUSAL WOMEN; STRENGTH; POROSITY; QUALITY; DENSITY; PUBERTY;
D O I
10.1016/j.jocd.2014.12.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although the region of interest in high-resolution peripheral quantitative computed tomography, defined based on the manufacturer's protocol for in vivo scanning, provides consistency and is practically convenient, it does not take into account possible variation in morphology in the regions adjacent to the measurement site. This study aimed at compare the morphologic variation in measurements using the standard fixed offset distance to define the distal starting slice against those obtained by using a relative measurement position scaled to the individual bone length at the distal radius and tibia in normal healthy adult subjects. A total of 40 healthy adult subjects (median height, 175.3 cm; range: 150.0-196.0 cm) were included in the study. High-resolution peripheral quantitative computed tomography at the distal radius and tibia was performed in all subjects, the region of interest defined by, first, the standard measurement protocol, where the most distal CT slice was 9.5 mm and 22.5 mm from the end plate of the radius and tibia, respectively, and second, the relative measurement method, where the most distal CT slice was at 4% and 7% of the radial and tibial lengths, respectively. Volumetric densities and microarchitectural parameters were compared between the 2 methods. Measurements of the total and cortical volumetric density and cortical thickness at the radius and tibia and cortical porosity, trabecular volumetric density, and trabecular number at the tibia were significantly different between the 2 methods (all p < 0.001). The predicted morphologic variation with varying measurement position was substantial at both the radius (up to 34%) and the tibia (up to 36%). A lack of consideration to height (and in turn the bone lengths) in the standard patient protocol could lead to the introduction of systematic errors in radial and tibial measurements. Although this may not be of particular significance in longitudinal studies in the same individual, it potentially assumes critical importance in cross-sectional studies.
引用
收藏
页码:217 / 225
页数:9
相关论文
共 50 条
  • [41] Distal radius plate of CFR-PEEK has minimal effect compared to titanium plates on bone parameters in high-resolution peripheral quantitative computed tomography: a pilot study
    de Jong, Joost J. A.
    Lataster, Arno
    van Rietbergen, Bert
    Arts, Jacobus J.
    Geusens, Piet P.
    van den Bergh, Joop P. W.
    Willems, Paul C.
    [J]. BMC MEDICAL IMAGING, 2017, 17
  • [42] High-resolution peripheral quantitative computed tomography for the assessment of acro-osteolysis and calcinosis in patients with systemic sclerosis
    Enevoldsen, Frederik Cosedis
    Therkildsen, Josephine
    Klose-Jensen, Rasmus
    Elkjaer, Amanda Lynggaard
    Naeser, Esben Uggerby
    Klicman, Rikke Fuglsang
    Aaen, Katja Thorup
    Sondergaard, Klaus Henrik
    Hauge, Ellen-Margrethe
    [J]. JOINT BONE SPINE, 2024, 91 (04)
  • [43] Precision of High-Resolution Peripheral Quantitative Computed Tomography Measurement Variables: Influence of Gender, Examination Site, and Age
    Paggiosi, Margaret A.
    Eastell, Richard
    Walsh, Jennifer S.
    [J]. CALCIFIED TISSUE INTERNATIONAL, 2014, 94 (02) : 191 - 201
  • [44] Multicenter precision of cortical and trabecular bone quality measures assessed by high-resolution peripheral quantitative computed tomography
    Burghardt, Andrew J.
    Pialat, Jean-Baptiste
    Kazakia, Galateia J.
    Boutroy, Stephanie
    Engelke, Klaus
    Patsch, Janina M.
    Valentinitsch, Alexander
    Liu, Danmei
    Szabo, Eva
    Bogado, Cesar E.
    Belen Zanchetta, Maria
    McKay, Heather A.
    Shane, Elizabeth
    Boyd, Steven K.
    Bouxsein, Mary L.
    Chapurlat, Roland
    Khosla, Sundeep
    Majumdar, Sharmila
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2013, 28 (03) : 524 - 536
  • [45] High-resolution peripheral quantitative computed tomography for the evaluation of bone erosions of metatarsophalangeal joints in patients with rheumatoid arthritis
    Meinhardsson, Jorgen Martin
    Klose-Jensen, Rasmus
    Therkildsen, Josephine
    Langdahl, Bente
    Hauge, Ellen-Margrethe
    Keller, Kresten Krarup
    [J]. INTERNATIONAL JOURNAL OF RHEUMATIC DISEASES, 2023, 26 (08) : 1512 - 1520
  • [46] Precision of bone mechanoregulation assessment in humans using longitudinal high-resolution peripheral quantitative computed tomography in vivo
    Walle, Matthias
    Whittier, Danielle E.
    Schenk, Denis
    Atkins, Penny R.
    Blauth, Michael
    Zysset, Philippe
    Lippuner, Kurt
    Mueller, Ralph
    Collins, Caitlyn J.
    [J]. BONE, 2023, 172
  • [47] Quality control for bone quality parameters affected by subject motion in high-resolution peripheral quantitative computed tomography
    Pauchard, Yves
    Liphardt, Anna-Maria
    Macdonald, Heather M.
    Hanley, David A.
    Boyd, Steven K.
    [J]. BONE, 2012, 50 (06) : 1304 - 1310
  • [48] Impaired bone microarchitecture in distal interphalangeal joints in patients with primary hypertrophic osteoarthropathy assessed by high-resolution peripheral quantitative computed tomography
    Q. Pang
    Y. Xu
    X. Qi
    L. Huang
    V.W. Hung
    J. Xu
    R. Liao
    Y. Hou
    Y. Jiang
    W. Yu
    O. Wang
    M. Li
    X. Xing
    W. Xia
    L. Qin
    [J]. Osteoporosis International, 2020, 31 : 153 - 164
  • [49] A Case Report of Abnormal Fracture Healing as Detected With High-Resolution Peripheral Quantitative Computed Tomography
    Heyer, Frans L.
    de Jong, Joost J. A.
    Smeets, Rob J. E. M.
    Arts, Jacobus J.
    Poeze, Martijn
    Geusens's, Piet E.
    van Rietbergen, Bert
    van den Bergh, Joop P.
    Willems, Paul C.
    [J]. JOURNAL OF CLINICAL DENSITOMETRY, 2017, 20 (04) : 486 - 489
  • [50] A customized protocol to assess bone quality in the metacarpal head, metacarpal shaft and distal radius: a high resolution peripheral quantitative computed tomography precision study
    Lynne Feehan
    Helen Buie
    Linda Li
    Heather McKay
    [J]. BMC Musculoskeletal Disorders, 14