An aptamer-SWNT biosensor for sensitive detection of protein via mediated signal transduction

被引:13
|
作者
Guo, Kai
Wang, Ying
Chen, Hui
Ji, Ji
Zhang, Song
Kong, Jilie
Liu, Baohong [1 ]
机构
[1] Fudan Univ, Key Lab Mol Engn Polymers, Chinese Minist Educ, Dept Chem, Shanghai 200433, Peoples R China
关键词
Aptamer; SWNT; Controlled assembly; Electrochemistry; Biosensor; ELECTROCHEMICAL DETECTION; CARBON; THROMBIN; DNA; RECOGNITION; SELECTION;
D O I
10.1016/j.elecom.2011.04.016
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
An aptamer-SWNT based electrochemical biosensor is developed for sensitive detection of thrombin via mediated signal transduction. To realize this purpose, a dense monolayer of 16-mercaptohexadecanoic acid was modified on the gold electrode. In the presence of thrombin. SWNTs were controllably assembled on this insulating monolayer, which could mediate efficient electron transfer between the electrode and eletroactive species to generate a larger redox current. Through detecting the redox signal mediated by SWNTs, this strategy could present significant signal amplification and a detection limit of 50 pM thrombin was achieved. Such an aptamer-SWNT based biosensor opens a rapid, selective and sensitive route for thrombin detection and offers a promising strategy for specific protein detection. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:707 / 710
页数:4
相关论文
共 50 条
  • [31] Highly sensitive detection of protein and small molecules based on aptamer-modified electrochemiluminescence nanoprobe
    Zhou, Xiaoming
    Duan, Ruixue
    Xing, Da
    ANALYST, 2012, 137 (08) : 1963 - 1969
  • [32] Bead assembly magnetorotation as a signal transduction method for protein detection
    Hecht, Ariel
    Commiskey, Patrick
    Shah, Nicholas
    Kopelman, Raoul
    BIOSENSORS & BIOELECTRONICS, 2013, 48 : 26 - 32
  • [33] A target-responsive autonomous aptamer machine biosensor for enzyme-free and sensitive detection of protein biomarkers
    Zou, Mengqi
    Li, Daxiu
    Yuan, Ruo
    Xiang, Yun
    JOURNAL OF MATERIALS CHEMISTRY B, 2018, 6 (24) : 4146 - 4150
  • [34] An electrochemical impedance biosensor with aptamer-modified pyrolyzed carbon electrode for label-free protein detection
    Lee, Jung A.
    Hwang, Seongpil
    Kwak, Juhyoun
    Park, Se Il
    Lee, Seung S.
    Lee, Kwang-Cheol
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 129 (01): : 372 - 379
  • [35] Sensitive Bifunctional Aptamer-Based Electrochemical Biosensor for Small Molecules and Protein
    Deng, Chunyan
    Chen, Jinhua
    Nie, Lihua
    Nie, Zhou
    Yao, Shouzhuo
    ANALYTICAL CHEMISTRY, 2009, 81 (24) : 9972 - 9978
  • [36] A ratiometric electrochemical aptasensor for sensitive detection of protein based on aptamer-target-aptamer sandwich structure
    Yu, Peng
    Zhou, Jiawan
    Wu, Liang
    Xiong, Erhu
    Zhang, Xiaohua
    Chen, Jinhua
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 732 : 61 - 65
  • [37] DNA aptamer-based sensitive electrochemical biosensor for NAD (H) detection
    Guo, Wenfei
    Wang, Haiyuan
    Wang, Zhaoyang
    Wu, Fandi
    He, Yao
    Liu, Yuan
    Deng, Yan
    Bing, Tao
    Qiu, Liping
    Tan, Weihong
    BIOSENSORS & BIOELECTRONICS, 2025, 271
  • [38] Aptamer biosensor for sensitive detection of toxin A of Clostridium difficile using gold nanoparticles synthesized by Bacillus stearothermophilus
    Luo, Peng
    Liu, Yi
    Xia, Yun
    Xu, Huajian
    Xie, Guoming
    BIOSENSORS & BIOELECTRONICS, 2014, 54 : 217 - 221
  • [39] A sensitive lateral flow biosensor for Escherichia coli O157:H7 detection based on aptamer mediated strand displacement amplification
    Wu, Wei
    Zhao, Shiming
    Mao, Yiping
    Fang, Zhiyuan
    Lu, Xuewen
    Zeng, Lingwen
    ANALYTICA CHIMICA ACTA, 2015, 861 : 62 - 68
  • [40] Sensitive and Homogeneous Protein Detection Based on Target-Triggered Aptamer Hairpin Switch and Nicking Enzyme Assisted Fluorescence Signal Amplification
    Xue, Liyun
    Zhou, Xiaoming
    Xing, Da
    ANALYTICAL CHEMISTRY, 2012, 84 (08) : 3507 - 3513