Matrix solid phase dispersion-assisted BCR sequential extraction method for metal partitioning in surface estuarine sediments

被引:25
作者
Martinez-Fernandez, Marta [1 ]
Carmen Barciela-Alonso, Maria [1 ]
Moreda-Pineiro, Antonio [1 ]
Bermejo-Barrera, Pilar [1 ]
机构
[1] Univ Santiago de Compostela, Fac Chem, Dept Analyt Chem Nutr & Bromatol, Santiago De Compostela 15782, Spain
关键词
Matrix solid phase dispersion; BCR; Sequential extraction; Estuarine sediments; Inductively coupled plasma mass spectrometry; HEAVY-METALS; ICP-MS; SOILS; SPECIATION; SINGLE; IMPROVEMENT; SAMPLES; ULTRASOUND; PROTOCOL; ELEMENTS;
D O I
10.1016/j.talanta.2010.10.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The BCR (the Community Bureau of Reference) of the European Union sequential extraction scheme for metal partitioning in estuarine sediments has been accelerated by using a matrix solid phase dispersion (MSPD) approach. The MSPD assisted BCR procedure consists of passing the extractants proposed by conventional BCR protocol (0.11 M acetic acid, 0.1 M hydroxylammonium chloride and 8.8 M hydrogen peroxide plus 1 M ammonium acetate) through the dispersed sample packaged inside a disposable syringe. Different silica-, magnesium- and aluminium-based materials were tested as dispersing agents and sea sand was found to offer the best performances. Variables for assisting the three stages of the BCR protocol were optimized, and accurate results were obtained when assisting the first and the third stages (exchangeable and oxidizable fractions, respectively). However, lack of accuracy was observed when assisting the second step (reducible fraction) and this result agrees with most of the assisted BCR procedures for which extracting the reducible fraction is the most troublesome stage. The organic matter oxidation (third stage) was successfully assisted by passing hydrogen peroxide at 50 C through the dispersed sample inside de syringe just before passing ammonium acetate. Therefore, the time-consuming and unsafe conventional organic matter oxidation processes, commonly performed even for microwave/ultrasounds assisted BCR procedures, are totally avoided. Inductively coupled plasma-mass spectrometry (ICP-MS) was used as a selective detector. The target elements were Cd, Co, Cr, Mn, Ni, Sr and Zn (first stage), Cd. Co and Ni (second stage), and Co, Cr, Mn, Ni, Sr and Zn (third stage). Repeatability of the method (n = 7) was good, and RSDs values of 9, 10, 10, 8, 8, 3 and 8% was obtained for Cd, Co, Cr, Mn, Ni, Sr and Zn, respectively (first stage); 10, 9 and 9% for Cd, Co and Ni, respectively (second stage); and 6, 2, 3, 4, 7 and 9% Co, Cr, Mn, Ni, Sr and Zn, respectively (third stage). The procedure was also validated by analysing two certified reference materials (CRM 601 and CRM 701). Good accuracy was obtained for the target elements extracted at the first stage: Cd (4.0 +/- 0.1 and 7.3 +/- 0.09 mu g g(-1) in CRM 601 and CRM 701, respectively), Cr (0.36 +/- 0.008 and 2.21 +/- 0.08 mu g g(-1) in CRM 601 and CRM 701, respectively), Ni (8.0 +/- 0.3 and 15.4 +/- 0.3 mu g g(-1) in CRM 601 and CRM 701, respectively) and Zn (262 +/- 3 and 203 +/- 3 mu g g(-1) in CRM 601 and CRM 701, respectively). Also, good accuracy was observed for elements extracted at the third step: Cd (1.8 +/- 0.09 and 0.29 +/- 0.03 mu g g(-1) in CRM 601 and CRM 701, respectively), Cr (145 +/- 4 mu g g(-1) in CRM 701), Ni (8.2 +/- 0.7 and 15.1 +/- 0.5 mu g g(-1) in CRM 601 and CRM 701, respectively) and Zn (45 +/- 0.7 mu g g(-1) in CRM 701). (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:840 / 849
页数:10
相关论文
共 36 条
[1]   Time saving modified BCR sequential extraction procedure for the fraction of Cd, Cr, Cu, Ni, Pb and Zn in sediment samples of polluted lake [J].
Arain, M. B. ;
Kazi, T. G. ;
Jamali, M. K. ;
Afridi, H. I. ;
Jalbani, N. ;
Sarfraz, R. A. ;
Baig, J. A. ;
Kandhro, G. A. ;
Memon, M. A. .
JOURNAL OF HAZARDOUS MATERIALS, 2008, 160 (01) :235-239
[2]   ISOLATION OF DRUG RESIDUES FROM TISSUES BY SOLID-PHASE DISPERSION [J].
BARKER, SA ;
LONG, AR ;
SHORT, CR .
JOURNAL OF CHROMATOGRAPHY, 1989, 475 :353-361
[3]   Matrix solid-phase dispersion [J].
Barker, SA .
JOURNAL OF CHROMATOGRAPHY A, 2000, 885 (1-2) :115-127
[4]  
BARKER SA, 1995, LC GC EUR, V11, P719
[5]   Matrix solid phase dispersion (MSPD) [J].
Barker, Steven A. .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2007, 70 (02) :151-162
[6]   Measurement of trace element distributions in soils and sediments using sequential leach data and a non-specific extraction system with chemometric data processing [J].
Cave, MR ;
Wragg, J .
ANALYST, 1997, 122 (11) :1211-1221
[7]   Metal fractionation in olive oil and urban sewage sludges using the three-stage BCR sequential extraction method and microwave single extractions [J].
Cid, BP ;
Alborés, AF ;
Gómez, EF ;
López, EF .
ANALYST, 2001, 126 (08) :1304-1311
[8]  
Cid BP, 2001, ANAL CHIM ACTA, V431, P209
[9]   Should acid ammonium oxalate replace hydroxylammonium chloride in step 2 of the revised BCR sequential extraction protocol for soil and sediment? [J].
Davidson, CM ;
Hursthouse, AS ;
Tognarelli, DM ;
Ure, AM ;
Urquhart, GJ .
ANALYTICA CHIMICA ACTA, 2004, 508 (02) :193-199
[10]   Effect of ultrasonic agitation on the release of copper, iron, manganese and zinc from soil and sediment using the BCR three-stage sequential extraction [J].
Davidson, CM ;
Delevoye, G .
JOURNAL OF ENVIRONMENTAL MONITORING, 2001, 3 (04) :398-403