Accuracy of eight-polar bioelectrical impedance analysis for the assessment of total and appendicular body composition in peritoneal dialysis patients

被引:51
作者
Medici, G
Mussi, C
Fantuzzi, AL
Malavolti, M
Albertazzi, A
Bedogni, G
机构
[1] Ctr Fegato, I-34012 Trieste, Italy
[2] Univ Modena & Reggio Emilia, Cattedra Nefrol, Modena, Italy
[3] Univ Modena & Reggio Emilia, Cattedra Geriatria, Modena, Italy
[4] Azienda USL, Modulo Sci Alimentaz & Dietet, Modena, Italy
[5] Univ Modena & Reggio Emilia, Cattedra Nutr Umana, Modena, Italy
关键词
body composition; bioelectrical impedance analysis; dual-energy X-ray absorptiometry; peritoneal dialysis;
D O I
10.1038/sj.ejcn.1602165
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Objective: To establish the accuracy of bioelectrical impedance analysis (BIA) for the assessment of total and appendicular body composition in peritoneal dialysis (PD) patients. Design: Cross-sectional study. Setting: University Nephrology Clinic. Subjects: In all, 20 PD patients and 77 healthy controls matched for gender, age and body mass index. Methods: Whole-body fat-free mass (FFM) and appendicular lean tissue mass (LTM) were measured by dual-energy X-ray absorptiometry. Resistance ( R) of arms, trunk and legs was measured by eight-polar BIA at frequencies of 5, 50, 250 and 500 kHz. Whole-body resistance was calculated as the sum of R of arms, trunk and legs. The resistance index ( RI) was calculated as the ratio between squared height and whole-body or segmental R. Results: RI at 500 kHz was the best predictor of FFM, LTMarm and LTMleg in both PD patients and controls. Equations developed on controls overestimated FFM and LTMarm and underestimated LTMleg when applied to PD patients. Specific equations were thus developed for PD patients. Using these equations, the percent root mean-squared errors of the estimate for PD patients vs controls were 5 vs 6% for FFM, 8 vs 8% for LTMarm and 7 vs 8% for LTMleg. Conclusion: Eight-polar BIA offers accurate estimates of total and appendicular body composition in PD patients, provided that population-specific equations are used.
引用
收藏
页码:932 / 937
页数:6
相关论文
共 21 条
[1]   Comparison of bioelectrical impedance analysis and dual-energy X-ray absorptiometry for the assessment of appendicular body composition in anorexic women [J].
Bedogni, G ;
Marra, M ;
Bianchi, L ;
Malavolti, M ;
Nicolai, E ;
De Filippo, E ;
Scalfi, L .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2003, 57 (09) :1068-1072
[2]   Accuracy of an eight-point tactile-electrode impedance method in the assessment of total body water [J].
Bedogni, G ;
Malavolti, M ;
Severi, S ;
Poli, M ;
Mussi, C ;
Fantuzzi, AL ;
Battistini, N .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2002, 56 (11) :1143-1148
[3]  
BHATLA B, 1995, ASAIO J, V41, pM442, DOI 10.1097/00002480-199507000-00048
[4]  
Borovnicar DJ, 1996, EUR J CLIN NUTR, V50, P607
[5]  
Cano N, 1999, Curr Opin Clin Nutr Metab Care, V2, P329, DOI 10.1097/00075197-199907000-00014
[6]  
Guo S.S., 1996, HUMAN BODY COMPOSITI, P191
[7]  
Konings CJAM, 2002, PERITON DIALYSIS INT, V22, P683
[8]  
Konings CJAM, 2003, PERITON DIALYSIS INT, V23, P184
[9]  
Kopple JD, 1997, ASAIO J, V43, P246
[10]   Nutritional status in dialysis patients:: a European consensus [J].
Locatelli, F ;
Fouque, D ;
Heimburger, O ;
Drüeke, TB ;
Cannata-Andía, JB ;
Hörl, WH ;
Ritz, E .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2002, 17 (04) :563-572